Osteoarthritis Clinical Trial
Official title:
A Comparison of Fixation Method in Total Knee Arthroplasty - Low Viscosity Versus High Viscosity Bone Cement. A Prospective Randomized Migration- and Bone Density Study on Primary Cemented Knee Implants.
The purpose of this study is to compare the early migration and periprosthetic bone changes of two total knee arthroplasties fixated with two different type bone cement.
Around 4% of total knee arthroplasties (TKA) are revised 15 years after the primary operation, most due to loosening of the implant. About 70 % TKA are fixed with bone cement and in general the results after total knee arthroplasty are excellent and with the existing technique about 95% well functioning prostheses can be expected 10 years post surgery. The most serious late complication to surgery is aseptic loosening of the implants; and this remains one of the main courses of failure of both uncemented and cemented total knee implants. Implant design, method of fixation, the quality of bone cement, surgerytechnique and the bone mass density are some of the factors that have a large influence on implant stability. Fixation of the tibia baseplates in total knee arthroplasty can be obtained by different type bone cement. In this project we are using a modular tibia component with a central wedge-shaped stem. Upon randomization at surgery the implant is consolidated in the bone with either low-viscosity or high-viscosity bone cement. The purpose of this study is to compare the early migration of a total knee implant fixated with two different bone cements using RSA (radio stereophotogrammetric analysis) for evaluation. Furthermore, we will make research into the periprosthetic bone and its changes post surgery using DEXA. Finally, the extend of the expected micromovements between the polyethylen liner and the metal backing of the titanium plateau will be compared and taken into account with the results. Several factors can influence the long-term survival of cemented TKA. Bone-sclerosing at the tibia condyles may induce a problem with cement penetration into the cancellous bone. Furthermore, blood-contamination in the cancellous bone may reduce the shear-strength at the bone-cement site by 50%. A solid cement-implant interface limits the amount of debris in the interface bringing down the risk of radiolucent lines and osteolysis. The tibial implant used in this study is designed with a rim under the plateau to support the cement layer on the tibial condyles at the time of fixation. The implant has a stem making it more resistant to shearing forces. In this study we primarily consider the bone cement viscosity on the outcome. Both types are used in hip-arthroplasties with good results. To evaluate both the implant-bone micromotions and the polyethylen-implant micromovements metal markers have been placed on the tibial implants pre-operatively. They will also be inserted into the tibial bone and into the tibial polyethylen intra-operatively allowing us to evaluate stereo x-rays by a photogrammetric computer analyses called RSA at the Orthopaedic Center, Aarhus University Hospital. Follow-up stereo x-rays will be scheduled for 1 week, 3 months, 6 month, 1 years and 2 years post-surgery. Periprostetic bone density will be evaluated at 1 week, 1 year and 2 years upon inclusion at the Orthopaedic Center, Aarhus University Hospital. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04657926 -
A Trial of APPA in the Treatment of Knee Osteoarthritis
|
Phase 2 | |
Completed |
NCT02536833 -
A Study Evaluating the Safety, Tolerability, and Efficacy of SM04690 Injected in the Target Knee Joint of Moderately to Severely Symptomatic Osteoarthritis Subjects
|
Phase 2 | |
Completed |
NCT03014037 -
Comparing Mesenchymal Stem Cell Counts in Unilateral vs. Bilateral Posterior Superior Iliac Spine Bone Marrow Aspiration
|
N/A | |
Recruiting |
NCT05937542 -
A Qualitative Investigation of CLEAT Participants
|
||
Completed |
NCT03644615 -
A Mindfulness Program (MBSR) in the Management of Symptomatic Hip and Knee Osteoarthritis
|
N/A | |
Recruiting |
NCT06061367 -
Muscles Strength and Gait Parameteres After TKA
|
||
Withdrawn |
NCT04976972 -
A Comparison of Patients Receiving a Total Knee Replacement With Robotic Assistance or With Conventional Instrumentation
|
N/A | |
Completed |
NCT05496205 -
A SAD Study to Evaluate the Safety, Tolerability and PK/PD of iN1011-N17 in Healthy Volunteers
|
Phase 1 | |
Completed |
NCT03850665 -
Comparison of Functional Outcome in Patients After Hip Arthroplasty Depending on Surgical Approach
|
N/A | |
Completed |
NCT02826902 -
Effect of Anesthesia on Quality of Recovery in Patients Undergoing Correctional Tibial Osteotomy - A Randomized Controlled Trial
|
N/A | |
Completed |
NCT04402502 -
Dynamic 4DCT to Examine Wrist Carpal Mechanics
|
N/A | |
Completed |
NCT02923700 -
Leukocyte-rich PRP vs Leukocyte-poor PRP for the Treatment of Knee Cartilage Degeneration: a Randomized Controlled Trial
|
Phase 4 | |
Completed |
NCT04564053 -
Study of Safety, Tolerability and Pharmacokinetics of LNA043 in Japanese Osteoarthritis Participants
|
Phase 1 | |
Completed |
NCT05070871 -
A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women
|
N/A | |
Not yet recruiting |
NCT05036174 -
Diphenhydramine Ointment for Knee Osteoarthritis
|
N/A | |
Recruiting |
NCT02666443 -
Low Dose Dexamethasone in Supraclavicular Blocks
|
N/A | |
Recruiting |
NCT02912429 -
Onlay vs. Inlay Patellofemoral Arthroplasty
|
N/A | |
Active, not recruiting |
NCT02723929 -
Effects of tDCS and tUS on Pain Perception in OA of the Knee
|
||
Withdrawn |
NCT02921594 -
Kinematic Comparison of Vanguard XP and Vanguard CR Total Knee Arthroplasties
|
N/A | |
Terminated |
NCT02820766 -
Journey II BCS CMS Total Knee System Compared to Other PS Total Knee Systems in PT Setting
|
N/A |