Orthopedic Disorder Clinical Trial
— OrthosimProOfficial title:
Imaging for the Generation of Personalized Biomechanical Models of the Musculoskeletal System Before and After Surgery
Advances in biomechanical modeling of musculoskeletal systems make it possible to consider the use of a digital clone of a patient to test surgical procedure before carrying it out on the patient himself. The study aims at evaluating the design and simulation procedure of anatomical and functional pre and post surgical patient-specific numerical models.
Status | Not yet recruiting |
Enrollment | 10 |
Est. completion date | October 15, 2023 |
Est. primary completion date | October 15, 2022 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 20 Years to 80 Years |
Eligibility | Inclusion Criteria: - If women, menopausal or on contraception if of childbearing age - Patients who will benefit from one of the orthopedic surgical procedures corresponding to the surgeries studied - Patient who is a member of a social security organization - Patient who has signed a written informed consent form Exclusion Criteria: - Patient refusal to participate in the study - Minor, - Patient under guardianship and / or curators, - Patient unable to receive information and express consent - Pregnant and/or breastfeeding women - Contraindication to MRI (presence of ferromagnetic materials, neurosurgical clips, vascular, pacemaker). - Non-affiliation to a social security scheme (beneficiary or entitled person) |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
Centre d'Investigation Clinique et Technologique 805 | Fondation Garches |
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Evaluation of simulated models regarding relative position of bones in static condition | comparison between real data (from imaging) vs simulated data regarding relative position of bones defining a joint:
angles between mechanical bone axis in degree in two situations: angles measured on pre operative imaging versus angles obtained on model 1 angles measured on post operative imaging versus angles obtained on model 3 |
18 months | |
Primary | Evaluation of simulated models regarding relative position of bones in dynamic condition: range of motion (ROM) | comparison between real data (from motion analysis) vs simulated data regarding relative position of bones defining a joint:
total joint range of motion (ROM) projected in anatomical planes : degree of freedom of the joint (flexion, extension, abduction, adduction, medial and lateral rotation) (Kinematic parameters) in two situations: ROM measured on pre operative motion analysis versus ROM obtained on model 1 ROM measured on post operative motion analysis versus ROM obtained on model 3 |
18 months | |
Primary | Evaluation of simulated models regarding forces | comparison between real data (from motion analysis) vs simulated data regarding kinetic parameters as forces (ground reaction forces)
in Newton (N) in two situations: forces measured on pre operative motion analysis versus forces obtained on model 1 forces measured on post operative motion analysis versus forces obtained on model 3 |
18 months | |
Primary | Evaluation of simulated models regarding moment | comparison between real data (from motion analysis) vs simulated data regarding kinetic parameters as joint moment
in Newton-metre (N.m) in two situations: moment calculated on pre operative motion analysis versus moment obtained on model 1 moment calculated on post operative motion analysis versus moment obtained on model 3 |
18 months | |
Primary | Evaluation of simulated models regarding pressure | comparison between real data (from motion analysis) vs simulated data regarding kinetic parameters as pressure (baropodometric analysis)
in Newton per square centimeter (N/cm2) in two situations: pressure measured on pre operative motion analysis versus pressure obtained on model 1 pressure measured on post operative motion analysis versus pressure obtained on model 3 |
18 months | |
Primary | comparison of post surgery changes in real and simulated results regarding bone dimension | comparison between real bone dimension's changes (from imaging) vs bone dimension's changes on simulated data
difference calculated in mm in one situation: - bone dimension's difference calculated on CT scan (difference between pre and post operative bone dimensions) versus bone dimension's difference calculated on models (difference between bone dimensions obtained on model 1 and model 3) |
18 months | |
Primary | comparison of post surgery changes in real and simulated results regarding bone torsion | comparison between real bone torsion's changes (from imaging) vs bone torsion's changes on simulated data,
difference calculated in degree in one situation: - bone torsion's difference calculated on CT scan (difference between pre and post operative bone torsions) versus bone torsion's difference calculated on models (difference between bone torsions obtained on model 1 and model 3) |
18 months | |
Primary | comparison of post surgery changes in real and simulated results regarding bone axis | comparison between real bone axis changes (from imaging) vs bone axis changes on simulated data : anatomical bone axis (corresponding mainly to the diaphyseal axis))
difference calculated in degree in one situation: - bone axis difference calculated on imaging (difference between pre and post operative bone torsion) versus bone torsion's difference calculated on models (difference between bone torsions obtained on model 1 and model 3) |
18 months | |
Primary | comparison of post surgery changes in real and simulated results regarding bone volume | comparison between real bone volume changes (from imaging) vs bone volume changes on simulated data
difference calculated in mm3 in one situation: - bone volume difference calculated on CT scan (difference between pre and post operative bone volumes) versus bone volume difference calculated on models (difference between bone volumes obtained on model 1 and model 3) |
18 months | |
Primary | comparison of post surgery changes in real and simulated results regarding relative position of bones in static condition | comparison between real mechanical angle changes (from imaging) vs mechanical angle changes on simulated data
difference between angles (obtained from mechanical bone axis) calculated in degree in one situation: - mechanical angle difference calculated on imaging (difference between pre and post operative mechanical angles) versus mechanical angle difference calculated on models (difference between mechanical angles obtained on model 1 and model 3) |
18 months | |
Primary | comparison of post surgery changes in real and simulated results regarding ROM's changes | comparison between real ROM'S changes (from motion analysis) vs ROM's changes on simulated data
joint range of motion's difference calculated in degree in one situation: - ROM's difference calculated on motion analysis (difference between pre and post operative ROM) versus ROM's difference calculated on models (difference between ROM obtained on model 1 and model 3) |
18 months | |
Primary | comparison of post surgery changes in real and simulated results regarding moment changes | comparison between real moment changes (from motion analysis) vs moment changes on simulated data
moment difference calculated in N.m in one situation: - moment difference calculated on motion analysis (difference between pre and post operative moments) versus moment difference calculated on models (difference between moments obtained on model 1 and model 3) |
18 months | |
Primary | comparison of post surgery changes in real and simulated results regarding pressure changes | comparison between real pressure changes (from motion analysis) vs pressure changes on simulated data
pressure difference calculated in N/cm2 in one situation: - pressure difference calculated on motion analysis (difference between pre and post operative pressures) versus pressure difference calculated on models (difference between pressures obtained on model 1 and model 3) |
18 months | |
Secondary | correlation of clinical scores and changes in function | changes in clinical scores (percentage) compared to the variation in the range of motion of joints studied | 18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding bone dimension | comparison between bone dimension in simulated surgery (model 2) and bone dimension in real surgery model (model 3)
difference calculated in mm |
18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding bone torsion | comparison between bone torsion in simulated surgery (model 2) and bone torsion in real surgery model (model 3)
difference calculated in degree |
18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding bone axis | comparison between bone axis in simulated surgery (model 2) and bone axis in real surgery model (model 3) : anatomical bone axis (corresponding mainly to the diaphyseal axis))
difference calculated in degree |
18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding bone volume | comparison between bone volume in simulated surgery (model 2) and bone volume in real surgery model (model 3)
difference calculated in mm3 |
18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding point-to-surface distance of bone | comparison of point-to-surface distance between two pairs of bones model 1/ model 2 and model 1/model 3
difference calculated in mm |
18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding relative position of bones in static condition | comparison between mechanical angle in simulated surgery (model 2) and mechanical angle in real surgery model (model 3)
difference between angles (obtained from mechanical bone axis) calculated in degree |
18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding ROM's changes | comparison between ROM in simulated surgery (model 2) and ROM in real surgery model (model 3)
joint range of motion's difference calculated in degree |
18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding ground reaction forces changes | comparison between forces in simulated surgery (model 2) and forces in real surgery model (model 3)
ground reaction forces difference calculated in Newton |
18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding moment changes | comparison between moment in simulated surgery (model 2) and moment in real surgery model (model 3)
moment difference calculated in N.m |
18 months | |
Secondary | Comparison of post surgery models between real and simulated surgery regarding pressure changes | comparison between pressure in simulated surgery (model 2) and pressure in real surgery model (model 3)
pressure difference calculated in N/cm2 |
18 months | |
Secondary | comparison of simulated joint force changes between Pre and post surgery models | comparison between simulated joint forces (from model 1) vs simulated joint forces (from model 2 and 3)
joint normal contact forces difference calculated in Newton |
18 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05864833 -
METabolism After Orthopedic Surgery
|
||
Completed |
NCT03286543 -
Electrical Stimulation for the Treatment of Pain Following Total Knee Arthroplasty Using the SPRINT Beta System
|
N/A | |
Recruiting |
NCT05461326 -
Quadriceps Tendon Versus Bone Patellar Tendon Bone Autograft ACL Reconstruction RCT
|
N/A | |
Completed |
NCT06080685 -
Efficacy of Character Strengths Intervention in Enhancing Character Strengths and Self-esteem Among Adolescents
|
N/A | |
Not yet recruiting |
NCT06326827 -
In'Oss™ (MBCP® Putty) Ortho
|
||
Not yet recruiting |
NCT06002009 -
SupraScapular Cuff Study: Assessing the Effects of Size and Type of Rotator Cuff Tear on Suprascapular Nerve Function
|
||
Completed |
NCT04730115 -
Evaluation of Architectural Changes in Mandibular Bone Pattern After Functional Treatment by Fractal Dimension Analysis
|
||
Withdrawn |
NCT03436667 -
Perioperative Factors Impacting Surgical Risk and Outcomes in Children
|
||
Completed |
NCT03299920 -
Opioid Consumption After Knee Arthroscopy
|
N/A | |
Active, not recruiting |
NCT05075525 -
EFFECT OF HIGH INTENSITY LASER IN PATELLOFEMORAL PAIN SYNDROME
|
N/A | |
Completed |
NCT06158165 -
Evaluating The Cardiovascular Effects of Tourniquet Application
|
||
Recruiting |
NCT04891549 -
Tension Band Versus Locking Plate Fixation for the Treatment of Patella Fractures
|
N/A | |
Recruiting |
NCT04676841 -
Wound Contamination During Orthopaedic Surgery
|
||
Not yet recruiting |
NCT03899298 -
Safety and Clinical Outcomes With Amniotic and Umbilical Cord Tissue Therapy for Numerous Medical Conditions
|
Phase 1 | |
Completed |
NCT04514601 -
A Quality Improvement Project to Assess and Refine the Handover Process at Morning Trauma Meetings
|
||
Not yet recruiting |
NCT04546594 -
Epidemiological Data on Pain
|
||
Completed |
NCT05396924 -
Rectal Temperature Measurement in Detecting Hypothermia During Hip Arthroscopy
|
N/A | |
Active, not recruiting |
NCT06438835 -
Development & Evaluation of Pneumatic Artificial Muscle(PAM) for Patients With Ankle Foot Orthosis(AFO)
|
N/A | |
Active, not recruiting |
NCT05795127 -
Risk for Reoperation After First MTP Joint Arthrodesis
|
||
Completed |
NCT04481711 -
Total Knee Arthroplasty and Clinical Findings
|
N/A |