Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01322919
Other study ID # 1001
Secondary ID
Status Completed
Phase Phase 3
First received March 23, 2011
Last updated May 19, 2015
Start date April 2010
Est. completion date March 2012

Study information

Verified date May 2015
Source Technolas Perfect Vision GmbH
Contact n/a
Is FDA regulated No
Health authority Mexico: Secretaria de SaludMexico: Ethics Committee
Study type Interventional

Clinical Trial Summary

By using a new software two consecutive laser treatments have been combined to correct the distance vision and to provide a near vision component in addition to the first treatment.

This study will help us to answer 2 questions:

1. How accurately this combined technique corrects distance and near vision

2. Whether the correction is adequate to remove the complete need for supplementary near spectacles


Description:

LASIK is a surgical technique where the cornea is reshaped using a laser to provide visual correction. Typically, this procedure will only correct your long distance vision requiring the use of supplementary spectacles for reading and near vision.

The Technolas 217z Excimer Laser used to deliver the treatment is approved for use in the European Community for both treatment versions to correct separately the near vision and the distance vision for cases which need one or the other correction.

By using a new software two consecutive treatments have been combined to correct the distance vision and to provide a near vision component in addition to the first treatment.

This study will help us to answer 2 questions:

1. How accurately this combined technique corrects distance and near vision

2. Whether the correction is adequate to remove the complete need for supplementary near spectacles


Recruitment information / eligibility

Status Completed
Enrollment 61
Est. completion date March 2012
Est. primary completion date February 2012
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Both
Age group 45 Years to 85 Years
Eligibility Inclusion Criteria:

- Subjects must be at least 45 years old and not older than 85 years

- Subjects must read, understand, and sign an Informed Consent Form (ICF).

- Subjects must be willing and able to return for scheduled follow up examinations through 6 months after surgery.

- Subjects must be willing to have both eyes treated with the laser during the same visit.

- Subjects for study arm-I must have up to +4 diopters (D) of absolute spherical hyperopia (not spherical equivalent), with up to +2.5 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction in both eyes. The spherical equivalent must be no more than +5.25 D. Subjects for study arm-II must have up to -7 diopters (D) of absolute spherical myopia (not spherical equivalent), with up to -4.0 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction in both eyes. The spherical equivalent must be no more than -9.00 D.

- Subjects must have presbyopia as determined by an age-related need for optical aid (> +1.50 D) for reading with their best distance correction.

- Subjects who have been screened successfully for acceptance of the PresbyLasik simulation

- Subjects who are contact lens wearers must have gas permeable (GP) lenses discontinued for at least 3 weeks and soft lenses discontinued for at least 1 week prior to the preoperative evaluation in the eye to be treated. Contact lens wearers who wear their contact lenses for any amount of time between the preoperative baseline examination and the operative visit must not be treated.

- Corneal topography should be normal.

- Subjects who are contact lens wearers must have 2 central keratometry readings and 2 manifest subjective refractions taken preoperatively at least one week apart. The refraction values must not differ by more than 0.50D as defined by manifest refraction spherical equivalent (MRSE). The keratometry values must not differ from the previous values by more than 0.50D in either meridian.

- High contrast, manifest, best spectacle-corrected logMAR distance visual acuity (VA) must be correctable to at least 0.1 (20/25 or 6/7.5) in both eyes.

Exclusion Criteria:

- Subjects for whom the combination of their baseline corneal thickness and the planned operative parameters for the LASIK procedure would result in less than 250 microns of remaining posterior corneal thickness below the flap postoperatively.

- Eyes for which the baseline manifest subjective refraction exhibits a difference of greater than 0.75D in sphere power, or a difference of greater than 0.50D in cylinder power, or a difference in cylinder axis of more than 15 degrees compared to the baseline cycloplegic subjective refraction. For manifest cylinder of less than 0.75D, the difference in cylinder axis will not be taken into consideration.

- Subjects for whom the preoperative assessment of the ocular topography indicates that one or both eyes are not suitable candidates for treatment based upon the suggested computer-simulated treatment plan.

- Any subject who is going to be co-managed by an ophthalmologist or optometrist who is not approved as a Technolas Perfect Vision GmbH Excimer laser Investigator.

- Subjects with anterior segment pathology, including dry eye syndrome and cataracts which in the Investigator's opinion, would interfere with best spectacle-corrected VA (BSCVA) or a successful treatment.

- Subjects with evidence of retinal vascular disease.

- Subjects with any residual, recurrent, or active ocular disease, or corneal abnormality that in the Investigator's opinion would interfere with BSCVA or a successful treatment.

- Subjects with signs of keratoconus.

- Subjects with unstable central keratometry readings with irregular mires.

- Subjects who have undergone previous intraocular or corneal surgery of any kind, including any type of excimer laser surgery for either refractive or therapeutic purposes.

- Subjects who have a history of Herpes simplex or Herpes zoster keratitis.

- Subjects who have a history of glaucoma or glaucoma suspect.

- Subjects who are immunocompromised or carrying diagnosis of connective tissue disease, clinically significant atopic disease, diabetes, autoimmune diseases and other acute or chronic illnesses that will increase the risk to the subject or confound the outcomes of this study.

- Subjects taking systemic medications likely to affect wound healing such as corticosteroids or antimetabolites.

- Subjects who are known to be pregnant, lactating, or who plan to become pregnant during the course of the study.

- Subjects with known sensitivity to medications used for standard LASIK.

- Subjects participating in any other ophthalmic clinical trials during this clinical trial.

- Subjects with an ocular muscle disorder including a strabismus or nystagmus, or other disorders affecting fixation.

- Subjects at risk for angle closure.

Study Design

Allocation: Non-Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment


Intervention

Procedure:
Supracor
All patients will undergo LASIK treatment on their non-dominant eye with a new laser software algorithm designed to treat both the distance and near vision components. The developed software algorithm uses the subjective refraction of the eye to create a treatment for the distance vision correction. This part of the treatment does not show any difference to a regular LASIK treatment for ametropic cases. In addition to the treatment for the distance vision a central ablation component will be added to address the near vision.

Locations

Country Name City State
Mexico Laser Ocular Hidalgo Monterrey N.l.

Sponsors (1)

Lead Sponsor Collaborator
Technolas Perfect Vision GmbH

Country where clinical trial is conducted

Mexico, 

References & Publications (8)

Alió JL, Amparo F, Ortiz D, Moreno L. Corneal multifocality with excimer laser for presbyopia correction. Curr Opin Ophthalmol. 2009 Jul;20(4):264-71. Review. — View Citation

Alió JL, Chaubard JJ, Caliz A, Sala E, Patel S. Correction of presbyopia by technovision central multifocal LASIK (presbyLASIK). J Refract Surg. 2006 May;22(5):453-60. — View Citation

Becker KA, Jaksche A, Holz FG. [PresbyLASIK: treatment approaches with the excimer laser]. Ophthalmologe. 2006 Aug;103(8):667-72. Review. German. — View Citation

Epstein RL, Gurgos MA. Presbyopia treatment by monocular peripheral presbyLASIK. J Refract Surg. 2009 Jun;25(6):516-23. — View Citation

Illueca C, Alió JL, Mas D, Ortiz D, Pérez J, Espinosa J, Esperanza S. Pseudoaccommodation and visual acuity with Technovision presbyLASIK and a theoretical simulated Array multifocal intraocular lens. J Refract Surg. 2008 Apr;24(4):344-9. — View Citation

Ortiz D, Alió JL, Illueca C, Mas D, Sala E, Pérez J, Espinosa J. Optical analysis of presbyLASIK treatment by a light propagation algorithm. J Refract Surg. 2007 Jan;23(1):39-44. — View Citation

Pinelli R, Ortiz D, Simonetto A, Bacchi C, Sala E, Alió JL. Correction of presbyopia in hyperopia with a center-distance, paracentral-near technique using the Technolas 217z platform. J Refract Surg. 2008 May;24(5):494-500. — View Citation

Telandro AP, Steile J 3rd. Presbyopia: perspective on the reality of pseudoaccommodation with LASIK. Ophthalmol Clin North Am. 2006 Mar;19(1):45-69, vi. Review. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary The percentage of treated patients with an uncorrected monocular high contrast Near VA of 20/40 or better 6 Months No
Secondary The percentage of treated eyes within +/- 1.00D of target refraction 6 Months No
Secondary The percentage of treated eyes within +/- 0.50D of target refraction 6 Months No
Secondary The percentage of treated eyes with a monocular uncorrected high contrast distance VA of 20/40 or better 6 Months No
Secondary Preservation of VA: Loss of more than 2 lines in monocular BCVA for distance vision 6 Months Yes
Secondary The percentage of treated eyes with an induced subjective manifest refraction cylinder not within +/- 2.00D 6 Months Yes
See also
  Status Clinical Trial Phase
Recruiting NCT04923841 - Myopia Control Using Bright Light Therapy, Myopic Defocus and Atropine N/A
Active, not recruiting NCT04080128 - Examination of Myopia Progression and Soft Bifocal Contact Lens Myopia Control N/A
Active, not recruiting NCT05275959 - Beijing (Peking)---Myopia and Obesity Comorbidity Intervention (BMOCI) N/A
Completed NCT04604405 - Effects of 650nm Low Energy Light on Human Retina and Choroid Microcirculation N/A
Recruiting NCT05594719 - The Effect of Sun-like Spectrum With Different Spectrum Composition on Retinal Blood Flow N/A
Completed NCT05594732 - The Effects of Different Outdoor Light Exposure Modes on Retinal Blood Flow N/A
Completed NCT04492397 - Comparing The Performance Of Two Different Daily Disposable Lenses (MIKI) N/A
Completed NCT04536571 - Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses N/A
Completed NCT06046209 - Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens N/A
Recruiting NCT06344572 - Pivotal Study of SAT-001 in Treatment of Pediatric Patient With Myopia Phase 3
Recruiting NCT05611294 - Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction N/A
Completed NCT05656885 - Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses N/A
Active, not recruiting NCT05534022 - Clinical Evaluation of a Myopia Control Lens in Slowing Myopia Progression. N/A
Completed NCT03934788 - the Clinical Performance of the Oxysoft Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT03701516 - Clinical Evaluation of Etafilcon A Contact Lenses Using a Novel Molding Process 2 N/A
Completed NCT05538754 - Post-Market Evaluation of the EVO ICL N/A
Completed NCT03139201 - Clinical Performance of the OxyAqua Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT02555722 - Evaluation of the CooperVision, Inc. Fanfilcon A and Enfilcon A Daily Wear Contact Lenses When Used for Frequent Replacement for up to One (1) Month of Daily Wear N/A
Not yet recruiting NCT06009458 - Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear N/A
Recruiting NCT05548478 - Corneal Endothelial Cell Injury Induced by Mitomycin-C N/A