Myopia Clinical Trial
Emtosecond lasers are used in cutting the flap in LASIK procedures (laser corrective surgery for refractive error). Their use has decreased the incidence of serious complications when compared to the use of microkeratomes(mechanical blades). The commonest femtosecond laser currently used is 'Intralase'. A newer femtosecond laser 'Visumax' (Zeiss) is now available and differs from the Intralase in that it does not interfere with the curvature of the cornea when creating the flap. The Intralase applanates the cornea flat during flap creation which causes the intraocular pressure to be higher. Both Intralase and Visumax lasers are available to patients and surgeons to use at SNEC. The aim of the investigators study is to compare the two lasers in a randomization of left and right eyes in the same patient. The investigators want to measure any difference that the lower intraocular pressure may have during the creation of the flap. This will be measured with a questionaire on patient experience during the procedure and the outcomes of vision, refraction, contrast sensitivity, wave-front analysis, tear function,corneal sensation and flap thickness measured with anterior segment OCT during the post-operative follow up period. To date no-one has compared the use of these two femtosecond lasers. Both lasers are currently used clinically for flap creation at SNEC.
n/a
Observational Model: Case Control, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04923841 -
Myopia Control Using Bright Light Therapy, Myopic Defocus and Atropine
|
N/A | |
Active, not recruiting |
NCT04080128 -
Examination of Myopia Progression and Soft Bifocal Contact Lens Myopia Control
|
N/A | |
Active, not recruiting |
NCT05275959 -
Beijing (Peking)---Myopia and Obesity Comorbidity Intervention (BMOCI)
|
N/A | |
Completed |
NCT04604405 -
Effects of 650nm Low Energy Light on Human Retina and Choroid Microcirculation
|
N/A | |
Recruiting |
NCT05594719 -
The Effect of Sun-like Spectrum With Different Spectrum Composition on Retinal Blood Flow
|
N/A | |
Completed |
NCT05594732 -
The Effects of Different Outdoor Light Exposure Modes on Retinal Blood Flow
|
N/A | |
Completed |
NCT04492397 -
Comparing The Performance Of Two Different Daily Disposable Lenses (MIKI)
|
N/A | |
Completed |
NCT04536571 -
Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses
|
N/A | |
Completed |
NCT06046209 -
Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens
|
N/A | |
Recruiting |
NCT06344572 -
Pivotal Study of SAT-001 in Treatment of Pediatric Patient With Myopia
|
Phase 3 | |
Recruiting |
NCT05611294 -
Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction
|
N/A | |
Completed |
NCT05656885 -
Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses
|
N/A | |
Active, not recruiting |
NCT05534022 -
Clinical Evaluation of a Myopia Control Lens in Slowing Myopia Progression.
|
N/A | |
Completed |
NCT03934788 -
the Clinical Performance of the Oxysoft Daily Disposable Silicone Hydrogel Soft Contact Lens
|
N/A | |
Completed |
NCT03701516 -
Clinical Evaluation of Etafilcon A Contact Lenses Using a Novel Molding Process 2
|
N/A | |
Completed |
NCT05538754 -
Post-Market Evaluation of the EVO ICL
|
N/A | |
Completed |
NCT03139201 -
Clinical Performance of the OxyAqua Daily Disposable Silicone Hydrogel Soft Contact Lens
|
N/A | |
Completed |
NCT02555722 -
Evaluation of the CooperVision, Inc. Fanfilcon A and Enfilcon A Daily Wear Contact Lenses When Used for Frequent Replacement for up to One (1) Month of Daily Wear
|
N/A | |
Not yet recruiting |
NCT06009458 -
Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear
|
N/A | |
Recruiting |
NCT05548478 -
Corneal Endothelial Cell Injury Induced by Mitomycin-C
|
N/A |