An automated quantitative meibomian gland analyzer based on all kinds of infrared meibomian gland images was develop to obtain more detail in meibomian gland, including width, length, area, signal intensity correlated to the quality of meibum, deformation index and ratio of area of each visible specific gland. The purpose of this study is present as separate sections the following points: (1) to compared the detailed characteristics of meibomian glands in normal subjects, Meibomian gland dysfunction (MGD) patients by the automated quantitative analyzer; (2) to identify the inter-examiner and intra-examiner repeatability of the new technique; (3) to explore the correlation among morphological and functional parameters of meibomian gland and risk factors,clinical symptoms and signs; (4) to explore the sensitivity and specificity of meibomian gland morphological and functional parameters in MGD diagnosis. (5) using morphological and functional parameters as new assessment of MGD severity and efficacy indicators for treatment.


Clinical Trial Description

Meibomian glands are essential for maintaining ocular surface health and integrity secrete various lipid components to forms a lipid layer to prevent excessive tear evaporation. Functional disorders of the meibomian glands, referred to today as meibomian gland dysfunction (MGD), are increasingly recognized as a high incidence disease commonly characterized by terminal duct obstruction and/or abnormal glandular secretion, often results in ocular surface epithelium damage, chronic blepharitis and dry eye disease that significantly reduces quality of life. A wide variation of the prevalence of MGD were reported from 0.39% to 69.3%, which is likely due to lack of diagnostic methods. To identify which clinical features are likely to be predictive of progressive disease in MGD may indicate the early diagnosis and proper treatment strategies. Histologic section through the normal meibomian glands and the obstructed human meibomian gland revealed that obstruction of orifice in MGD could lead to dilation of the central duct, damage of the secretory meibocytes and finally result in atrophy of dilated meibomian glands and glands drop-out. It was thus be accepted that detailed changes of meibomian glands morphology are key signs to diagnose and evaluate the severity of MGD. The detailed changes including dilation, distortion, shortening and loss of visualisation of glands which can be directly observed and visual assessment by the developed of non-contact meibomian gland infrared imaging technology. Quantitative evaluations of meibomian glands were obtain by developing imaging processing techniques. The most common use is the image editing software Image J (National Institute of Health; http://imagej.nih.gov/ij) which can identify the gland region on the image manually by the users and may lead to inter-observer variability. Koh et al., first applied original algorithms to automatically analysed gland loss in meibography images with a manually pre-processing. Reiko et al., then develop an objective and automatic system to measure the meibomian gland area. However, the existing methods of meibomian gland analysis have been limited to clinical use where large number of images needs to be analyzed efficiently due to the inter-observer variability or time-consuming process. Meanwhile, the existing quantitative morphological parameters obtain by those imaging processing techniques, including percentage of MG drop-out and gland atrophy area, were suggested to not only be advanced stages or terminal changes in MGD, but also occurs as an age-related atrophic process. The early findings of MGD induced by the primary pathologic obstruction including degenerative gland dilation, irregularly shapes of gland and change of meibum quality are still difficult to be evaluated automatically and quantitively from the image. Moreover, the meibomian gland drop-out is still an approximate assessment without specific pattern. Whether the atrophy or loss occur in upper or lower eyelids, central, distal or proximal, total loss of gland or partial loss of gland has the greatest effect on the pathology progress of MGD will be important to identify. Thus, a comprehensive analysis technique to automatically detect multi-information of meibomian gland morphology will benefit the future early diagnosis and management of MGD. Recently, an automated quantitative meibomian gland analyzer based on all kinds of infrared meibomian gland images was develop to obtain more detail in meibomian gland, including width, length, area, signal intensity correlated to the quality of meibum, deformation index and ratio of area of each visible specific gland. The purpose of this study is present as separate sections the following points: (1) to compared the detailed characteristics of meibomian glands in normal subjects and MGD patients by the automated quantitative analyzer; (2) to identify the inter-examiner and intra-examiner repeatability of the new technique; (3) to explore the correlation among morphological and functional parameters of meibomian gland and risk factors,clinical symptoms and signs; (4) to explore the sensitivity and specificity of meibomian gland morphological and functional parameters in MGD diagnosis. (5) using morphological and functional parameters as new assessment of MGD severity and efficacy indicators for treatment. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04052841
Study type Interventional
Source Zhongshan Ophthalmic Center, Sun Yat-sen University
Contact Yuqing Deng, MD
Phone 18120557291
Email 15927646647@163.com
Status Recruiting
Phase N/A
Start date October 12, 2020
Completion date December 1, 2023

See also
  Status Clinical Trial Phase
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT04884243 - Safety, Efficacy and Pharmacokinetics of CBT-006 in Patients With Meibomian Gland Dysfunction Phase 2
Active, not recruiting NCT04425551 - Effect of Micropulse Laser on Dry Eye Disease Due to Meibomian Gland Dysfunction N/A
Terminated NCT02596919 - Fast Infrared Meibography (Photography) N/A
Completed NCT01207752 - The Efficacy of an Ocular Emulsion in Meibomian Gland Dysfunction N/A
Completed NCT05162261 - to Evaluate the Effectiveness and Safety of the Tixel® , VS LipiFlow® in the Treatment of Meibomian Gland Dysfunction N/A
Recruiting NCT06064071 - Clinical Study Evaluating Nordlys™ SWT IPL for Dry Eye Disease (DED) Due to MGD N/A
Completed NCT03652051 - A Multicenter Study Evaluating AZR-MD-001 in Patients With Meibomian Gland Dysfunction and Evaporative Dry Eye Disease (DED) Phase 2
Recruiting NCT03767530 - Efficacy and Safety of Thermic Devices in the Treatment of Meibomian Gland Dysfunction N/A
Active, not recruiting NCT05577910 - Vectored Thermal Pulsation, Intense Pulsed Light, and Eyelid Warm Compress Therapies for MGD N/A
Completed NCT04889950 - Clinical Study to Evaluate the Safety and Effectiveness of The Tixel Fractional System in the Treatment of Meibomian Gland Disfunction N/A
Recruiting NCT06004895 - Mechanisms of Light-based Therapies for Dry Eye Disease N/A
Completed NCT04147962 - Intense Pulsed Light in Meibomian Gland Dysfunctions
Completed NCT02256969 - Intraductal Meibomian Gland Probing Trial Phase 4
Recruiting NCT05089591 - Intense Pulsed Light in Meibomian Gland Dysfunction N/A
Completed NCT04500821 - Evaluation of the LipiFlow System With a New Activator N/A
Completed NCT03318874 - Optimization of the Treatment of Dry Eye Disease Caused by Meibomian Gland Dysfunction Phase 4
Completed NCT06278584 - iLux Treatment for Meibomian Gland Dysfunction N/A
Completed NCT05028491 - The Influence of Meibomian Gland Expression on Corneal Aberrations in MGD Patients
Completed NCT03617315 - Crosslinked Hyaluronic Acid With Liposomes and Crocin in Dry Eye N/A