Failure to wean from mechanical ventilation (failure to get the patients off the breathing machine) is associated with prolonged stay in the intensive care unit and increased risk of death. Some patients have difficulty successfully getting off the ventilator and breathing on their own. Usually this difficulty is due to lung problems. But sometimes it is due to heart problems, or heart failure. To improve a patient's chances of successfully getting off the ventilator early, it is helpful to the doctors to know if patient has heart failure and to measure how severe. With the new monitoring system being studied here, doctors may be able to detect and measure heart failure more easily. A new monitor (Vigileo TM) that is connected with a specific cable (Flo-TracTM) to a catheter that is inside the patient's artery (arterial line) has lately been developed. This monitor can estimate the amount of blood that the heart is pumping per minute, known as cardiac output. The heart is supposed to pump blood harder when a patient is being weaned from the breathing machine. With the above mentioned monitor, we hope to detect those patients whose hearts are weak and are not pumping as hard as they should.


Clinical Trial Description

In the process of liberation or discontinuation from mechanical ventilation (also commonly referred as "weaning") the goal is to achieve spontaneous breathing and ultimately extubation. Weaning failure occurs in up to 25% of patients who meet criteria for weaning, especially in those with underlying COPD or heart failure (1). Weaning failure is well known to prolong intensive care unit (ICU) stay, and to increase morbidity and mortality in critically ill patients. Early identification and treatment of causes of weaning failure is of paramount importance to improve outcome in difficult to wean patients. Although respiratory system failure is the most common cause of weaning failure, occult cardiovascular insufficiency occurs very often in critically ill patients, and it can contribute to, or be the only cause of weaning failure in many patients (2). Recognition of cardiovascular origin of weaning failure is crucial since the use of vasodilators and/or diuretics may result in successful weaning (1). Cardiovascular instability during liberation from mechanical ventilation was first described more than 30 years ago by Beach et al (3) in post-operative cardiac surgery patients. Since then, a few other studies have described the hemodynamic changes both in patients who underwent successful and unsuccessful weaning form mechanical ventilation (1,4,5,6,7). Lemaire et al. (4) emphasized the use of a pulmonary artery catheter as the "gold standard" to detect left ventricular dysfunction during spontaneous breathing trial (SBT). They reported a markedly increased in pulmonary artery occlusion pressure (PAOP) in patients who were suffering from COPD or heart failure who failed to wean from mechanical wentilation. Jubran et al. (5) reported an increase in PAOP, decreased mixed venous oxygen saturation (SvO2) and an increase in the oxygen extraction ratio in a group of patients who failed to wean from mechanical ventilation. In contrast, De Backer et al. (6) described an increase in cardiac index in a group of patients who were successfully weaned after cardiac surgery. A recently published study by Frazier et al. (7) corroborated previous data by comparing the hemodynamic changes between a group of patients who were successfully weaned and a group of patients who failed to wean from mechanical ventilation. The cardiac output and stroke volume were estimated by the differential Fick partial rebreathing technique, with carbon dioxide as the indicator substance. The group of patients who were successfully weaned had a statistical significant increase in both stroke volume and cardiac index, unlike the group that failed weaning. The physiologic changes that explain the above mentioned findings in hemodynamic parameters during weaning are complex and not fully understood (1). It is well known that weaning can place an excessive burden on the heart and it can be considered a form of "exercise" (2). As studied by exercise physiologists, the increase in oxygen consumption during exercise in healthy individuals is matched both by an increase in cardiac output and oxygen extraction. In patients with overt heart failure, the increase in cardiac output is inadequate, and the predominant response constitutes and increase in oxygen extraction. Return to spontaneous breathing induces alteration in intrathoracic pressures that influence cardiovascular function, producing, among other changes, an increase in venous return. Other postulated physiologic changes include increase sympathetic tone, weaning-induced myocardial ischemia and increased ventricular interdependence (2). The recognition of cardiac origin of weaning failure is of vital importance. Unfortunately, the clinical signs of patients who fail weaning because of acute heart failure (tachypnea, tachycardia, anxiety, etc) are often difficult to distinguish from signs of respiratory failure. Reliable bedside minimally invasive monitoring tools and tests need to be developed to help the clinician in identifying these patients and help titrate cardiovascular therapies during weaning trials. Currently, the list of such tools is short and the validity of each technique in different situations is unknown (2). Cardiovascular dysfunction may be the missing piece in predicting weaning success. Cardiovascular monitoring can be useful in identifying and managing patients who fail to wean due to lack of cardiac reserve. We propose the use of Flo-Trac/VigileoTM, a semi-invasive technique that estimates cardiac output from the arterial pressure waveform, as a tool for cardiac monitoring during the process of weaning from mechanical ventilation. References: 1. Richard C and Teboul JL. Weaning failure from cardiovascular origin. Intensive Care Med 2005;31:1605-1607 2. Pinsky MR. Breathing as exercise. Intensive care Med 2000;26:1164-1166 3. Beach T, Millen E, Grenvik A. Hemodynamic response to discontinuation from mechanical ventilation. Crit Care med 1973;1:85-90 4. Lemaire F, Teboul JL, Cinotti L, Giotto G, Abrouk F, Steg G, Macquin-Mavier I and Zapol W. Acute left ventricular dysfunction during unsuccessful weaning from mechanical ventilation. Anesthesiology 1998;69:171-179 5. Jubran A, Mathru M, dries D and Tobin MJ. Continuous recordings from Mixed Venous Oxygen Saturation during Weaning from Mechanical Ventilation and the Ramifications Thereof. Am J Respir Crit Care Med 1998:158:1763-1769 6. De Backer D, El Haddad P, Preiser JC and Vincent JL. Hemodynamic responses to successful weaning from mechanical ventilation after cardiovascular surgery. Intensive Care Med 2000;26:1201-1206 7. Frazier SK et al. Hemodynamic changes during discontinuation of mechanical ventilation in medical intensive care unit patients. Am J Crit Care 2006;15:580-593 ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00631683
Study type Observational
Source The University of Texas Health Science Center, Houston
Contact
Status Withdrawn
Phase
Start date February 2008
Completion date February 2008

See also
  Status Clinical Trial Phase
Completed NCT05921656 - Construction and Evaluation of Airway Leakage Risk Model of Patients With Endotracheal Tube
Recruiting NCT03941002 - Continuous Evaluation of Diaphragm Function N/A
Withdrawn NCT04288076 - The Brain and Lung Interaction (BALI) Study N/A
Completed NCT03031860 - Semi-quantitative Cough Strength Score (SCSS) N/A
Completed NCT02545621 - A Role for RAGE/TXNIP/Inflammasome Axis in Alveolar Macrophage Activation During ARDS (RIAMA): a Proof-of-concept Clinical Study
Completed NCT02312869 - Local Assessment of Management of Burn Patients N/A
Completed NCT01885442 - TryCYCLE: A Pilot Study of Early In-bed Leg Cycle Ergometry in Mechanically Ventilated Patients N/A
Completed NCT01204281 - Proportional Assist Ventilation (PAV) in Early Stage of Critically Ill Patients Phase 4
Terminated NCT01059929 - Dexmedetomidine Versus Propofol in the Medical Intensive Care Unit (MICU) Phase 4
Completed NCT00824239 - Intermittent Sedation Versus Daily Interruption of Sedation in Mechanically Ventilated Patients Phase 3
Completed NCT00529347 - Mechanical Ventilation Controlled by the Electrical Activity of the Patient's Diaphragm - Effects of Changes in Ventilator Parameters on Breathing Pattern Phase 1
Unknown status NCT00260676 - Protective Ventilatory Strategy in Potential Organ Donors Phase 3
Terminated NCT00205517 - Sedation and Psychopharmacology in Critical Care N/A
Completed NCT03281785 - Ultrasound of Diaphragmatic Musculature in Mechanically Ventilated Patients. N/A
Recruiting NCT04110613 - RCT: Early Feeding After PEG Placement N/A
Completed NCT04410783 - The Emergency Department Sedation Pilot Trial N/A
Recruiting NCT04821453 - NAVA vs. CMV Crossover in Severe BPD N/A
Completed NCT03930147 - Ventilation With ASV Mode in Children N/A
Recruiting NCT05029167 - REstrictive Versus LIberal Oxygen Strategy and Its Effect on Pulmonary Hypertension After Out-of-hospital Cardiac Arrest (RELIEPH-study) N/A
Recruiting NCT04849039 - Lung Microbiota and VAP Development (PULMIVAP)