Lung Cancer Clinical Trial
Official title:
Investigating Radiation-Induced Injury to Airways and Pulmonary Vasculature in Lung Stereotactic Ablative Body Radiotherapy (SAbR)
We will conduct a prospective clinical study involving up to 40 non-Small Cell Lung Cancer (nSCLC) patients to determine dose thresholds for central and peripheral BSS elements. All imaging will be performed under motion control (e.g., with or without abdominal compression) defined as breathing with a resultant motion ≤5mm by fluoroscopy. In this study, a high-resolution breath-hold CT scan (BHCT) will be acquired from each patient immediately before or after the 4DCT scan. A follow-up high resolution BHCT (also under motion control) will be acquired from each patient 8-12 months post-SabR, and BSS elements will be segmented in LungPointRT. A radiation oncologist will compare the pre- and post-SabR contours to determine segmental collapse.
We will conduct a prospective clinical study involving up to 40 non-Small Cell Lung Cancer (nSCLC) patients to determine dose thresholds for central and peripheral BSS elements. The workflow is illustrated in Fig. 4. all imaging will be performed under motion control (e.g., with or without abdominal compression) defined as breathing with a resultant motion [LessThanorequalTo]5mm by fluoroscopy. Before 4DCT simulation, fluoroscopy using a stand-alone system is used to assess motion under free-breathing conditions. For those with inherent motion [LessThanorequalTo]5mm, no motion manipulation is required (ie, motion is controlled). For those with [Greater Than]5mm motion, it is customary to use progressively tighter abdominal compression applied via commercially available device or a pneumatic belt, until respiration-induced tumor motion, as seen under fluoroscopy, is [LessThanorequalTo] 5mm. Subsequently, a 4DCT scan is acquired with motion control. in this study, a high-resolution breath-hold CT scan (BHCT) will be acquired from each patient immediately before or after the 4DCT scan. using LungPoint, a virtual bronchoscopy software, individual BSS will be auto-segmented from the BHCT, labeled based on a nomenclature described by netter and exported as Digital imaging and Communications in Medicine radiation Therapy (DiCoMRT) objects to the planning system. The BHCT will be deformably registered to each phase of the 4DCT to create ten high-resolution CT volumes corresponding to ten respiratory phases. acquiring both, the BHCT and the 4DCT, under motion control will ensure that the anatomy is consistently deformed so as to minimize image registration errors. The automatically deformed contours, especially for smaller BSS elements, will be manually verified by a radiation oncologist, and corrected if necessary. a high-resolution maximum intensity projection (MiP) image will be created from the deformed BHCT volumes so as to encompass the extent of respiration-induced motion for each structure in the lung. The high spatial resolution of the MiP will ensure that respiratory motion of smaller, more peripheral BSS segments is captured accurately. The dose to BSS elements from the clinical SabR plan (created without considering BSS) will be computed from the hi-res MiP using the acuros dose calculation algorithm. This algorithm accurately accounts for dose to small structures and tissue inhomogeneities, and has been extensively validated for lung radiotherapy. a follow-up high resolution BHCT (also under motion control) will be acquired from each patient 8-12 months post-SabR, and BSS elements will be segmented in LungPointRT. a radiation oncologist will compare the pre- and post-SabR contours to determine segmental collapse. univariate and multivariate stepwise generalized estimating equation (Gee) analyses will be conducted to identify significant factors contributing to BSS collapse, accounting for intra-patient correlation within each nSCLC patient. The insights obtained from these analyses will be used to formulate dose-thresholds for BSS segments. For each segment, we will compute the probability of segmental collapse as a function of dose, Cs(D) and also assign a weight [and] #955;s. This weight will be based on the findings of aim 2 and will be proportional to the functional lung volume [Quote]served[Quote] by that segment. This weighting scheme will ensure that the dose-thresholds (DT) are set more conservatively, i.e., with relatively lower Cs(DT) for the more critical BSS segments and vice versa. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03918538 -
A Series of Study in Testing Efficacy of Pulmonary Rehabilitation Interventions in Lung Cancer Survivors
|
N/A | |
Recruiting |
NCT05078918 -
Comprehensive Care Program for Their Return to Normal Life Among Lung Cancer Survivors
|
N/A | |
Active, not recruiting |
NCT04548830 -
Safety of Lung Cryobiopsy in People With Cancer
|
Phase 2 | |
Completed |
NCT04633850 -
Implementation of Adjuvants in Intercostal Nerve Blockades for Thoracoscopic Surgery in Pulmonary Cancer Patients
|
||
Recruiting |
NCT06037954 -
A Study of Mental Health Care in People With Cancer
|
N/A | |
Recruiting |
NCT06006390 -
CEA Targeting Chimeric Antigen Receptor T Lymphocytes (CAR-T) in the Treatment of CEA Positive Advanced Solid Tumors
|
Phase 1/Phase 2 | |
Recruiting |
NCT05583916 -
Same Day Discharge for Video-Assisted Thoracoscopic Surgery (VATS) Lung Surgery
|
N/A | |
Completed |
NCT00341939 -
Retrospective Analysis of a Drug-Metabolizing Genotype in Cancer Patients and Correlation With Pharmacokinetic and Pharmacodynamics Data
|
||
Not yet recruiting |
NCT06376253 -
A Phase I Study of [177Lu]Lu-EVS459 in Patients With Ovarian and Lung Cancers
|
Phase 1 | |
Recruiting |
NCT05898594 -
Lung Cancer Screening in High-risk Black Women
|
N/A | |
Active, not recruiting |
NCT05060432 -
Study of EOS-448 With Standard of Care and/or Investigational Therapies in Participants With Advanced Solid Tumors
|
Phase 1/Phase 2 | |
Active, not recruiting |
NCT03575793 -
A Phase I/II Study of Nivolumab, Ipilimumab and Plinabulin in Patients With Recurrent Small Cell Lung Cancer
|
Phase 1/Phase 2 | |
Active, not recruiting |
NCT03667716 -
COM701 (an Inhibitor of PVRIG) in Subjects With Advanced Solid Tumors.
|
Phase 1 | |
Terminated |
NCT01624090 -
Mithramycin for Lung, Esophagus, and Other Chest Cancers
|
Phase 2 | |
Terminated |
NCT03275688 -
NanoSpectrometer Biomarker Discovery and Confirmation Study
|
||
Not yet recruiting |
NCT04931420 -
Study Comparing Standard of Care Chemotherapy With/ Without Sequential Cytoreductive Surgery for Patients With Metastatic Foregut Cancer and Undetectable Circulating Tumor-Deoxyribose Nucleic Acid Levels
|
Phase 2 | |
Recruiting |
NCT06052449 -
Assessing Social Determinants of Health to Increase Cancer Screening
|
N/A | |
Recruiting |
NCT06010862 -
Clinical Study of CEA-targeted CAR-T Therapy for CEA-positive Advanced/Metastatic Malignant Solid Tumors
|
Phase 1 | |
Not yet recruiting |
NCT06017271 -
Predictive Value of Epicardial Adipose Tissue for Pulmonary Embolism and Death in Patients With Lung Cancer
|
||
Recruiting |
NCT05787522 -
Efficacy and Safety of AI-assisted Radiotherapy Contouring Software for Thoracic Organs at Risk
|