Labor Pain Clinical Trial
Official title:
Use of Color Doppler Ultrasonography to Confirm the Position of a Labor Epidural Needle - a Retrospective Case Series
Color Flow Doppler (CFD) utilizes Doppler information obtained from signals sent to and received from a transducer. This information is color-encoded and then displayed as color on an overlay of the two-dimensional image. The color scale represents both speed and direction of flow within a discrete area of the image. CFD has been recently used to determine the position of the epidural catheter. However its role in labor epidural has yet to be defined. This study describes the use of CFD to confirm the position of the tip of the epidural needle in the context of labor analgesia. This study hypothesized that CFD is a feasible method for identifying proper epidural needle placement prior to epidural catheter advancement.
After obtaining approval by the Institutional Review Board and a waiver of informed consent,
thirty-five pregnant patients who underwent an ultrasound guided labor epidural between
August of 2017 and June of 2018, were included in this retrospective review. The ultrasound
guided labor epidural was used in those in which an anticipated technical difficulty with
landmark epidural space localization was expected. These included those patients with
diagnosis of obesity and lumbar scoliosis, as well as those with poorly defined surface
lumbar bone anatomy. Patients with history of spine surgery were excluded. Patient data were
obtained from the institutional electronic medical records. Demographic data, intervertebral
level of insertion, dermatome level, and failure rate of epidural needle placement using
color flow Doppler were noted for each patient.
Labor analgesia was obtained via a combined spinal epidural technique. Sterile preparation
and draping of the area was followed by placement of a curvilinear ultrasound transducer in a
sterile sheath. The ultrasound was used to identify the interspinous space. The epidural
needle was guided with the use of real time ultrasound by the use of an out of plane
technique. A two hand technique was used to manipulate the needle and the ultrasound probe. A
17G Tuohy needle (B. Braun Medical Inc, Bethlhem, PA, USA) was advanced until loss of
resistance to normal saline was attained. Confirmation of the epidural space with the use of
color flow Doppler (CFD) was then obtained after injection of up to 10 mL of normal saline
through the epidural needle. A 27G pencil-point spinal needle (B. Braun Medical Inc,
Bethlhem, PA, USA) was then introduced through the epidural needle until cerebro-spinal fluid
(CSF) was obtained. Use of intrathecal fentanyl or local anesthetic plus fentanyl was then
used as a bolus in the spinal space. A 21G epidural catheter (B. Braun Medical Inc, Bethlhem,
PA, USA) was then threaded into the epidural space.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03539562 -
Therapeutic Rest to Delay Admission in Early Labor: A Prospective Study on Morphine Sleep
|
||
Withdrawn |
NCT04662450 -
Evaluation and Management of Parturients' Pain Intensity
|
N/A | |
Completed |
NCT02885350 -
Spinal or Epidural Fentanyl or Sufentanil for Labour Pain in Early Phase of the Labour
|
Phase 4 | |
Completed |
NCT02550262 -
Programmed Intermittent Epidural Bolus for Labor Analgesia During First Stage of Labor
|
N/A | |
Completed |
NCT01598506 -
Intrathecal Hydromorphone for Labor Analgesia
|
Phase 2 | |
Withdrawn |
NCT01636999 -
Comparing Sedara to Butorphanol in Early Labor
|
N/A | |
Completed |
NCT00987441 -
Epidural Labor Analgesia and Infant Neurobehavior
|
N/A | |
Completed |
NCT00755092 -
Effect of Doula in Nulliparas and Multiparas
|
N/A | |
Terminated |
NCT00787176 -
The Association Between Fluid Administration, Oxytocin Administration, and Fetal Heart Rate Changes
|
N/A | |
Recruiting |
NCT06036797 -
Efficacy and Safety of Hydromorphone-ropivacaine Versus Sufentanil-ropivacaine for Epidural Labor Analgesia
|
Phase 2 | |
Completed |
NCT05512065 -
Changes in Velocimetric Indices of Uterine and Umbilical Arteries Before and After Combined Spinal-epidural Analgesia in Laboring Women
|
N/A | |
Completed |
NCT05327088 -
Epidural Dexmedetomidine vs Nalbuphine for Labor Analgesia
|
Phase 2 | |
Completed |
NCT03103100 -
Comparing Bupivacaine, Lidocaine, and a Combination of Bupivacaine and Lidocaine for Labor Epidural Activation
|
Phase 3 | |
Recruiting |
NCT03623256 -
Comparison of Intrathecal Versus Epidural Fentanyl on Fetal Bradycardia in Labor Combined Spinal Epidural Analgesia
|
Phase 4 | |
Active, not recruiting |
NCT02271100 -
Assessment of the Use of Ultrasound for Epidural Catheter Placement and Comparison With Palpation Technique
|
N/A | |
Completed |
NCT02926469 -
Virtual Reality Analgesia in Labor: The VRAIL Pilot Study
|
N/A | |
Completed |
NCT03712735 -
Programmed Intermittent Epidural Bolus For Laboring Obstetrical Women
|
Phase 4 | |
Not yet recruiting |
NCT05565274 -
Outcome of Combined Tramadol and Paracetamol Versus Pentazocine as Labour Analgesia Among Parturients
|
N/A | |
Recruiting |
NCT01708668 -
The Effects of Intermittent Epidural Bolus on Fever During Labor Analgesia
|
N/A | |
Recruiting |
NCT02575677 -
Oxycodone in Treatment of Early Labour Pain Efficacy and Safety
|