Clinical Trials Logo

Clinical Trial Summary

Today, tooth- or implant-supported single crowns and short-span fixed partial dentures can be fabricated on the basis of an intraoral scan, but the scanning accuracy decreases with increasing length of the jaw section to be captured. An accurate scan is also made more difficult by edentulous jaw sections, as these provide the scanner with few landmarks for proper three-dimensional image composition. With respect to both edentulous and edentulous patients with dental implants, the currently available literature does not provide a firm basis for deciding whether such patients can already be scanned with sufficient accuracy. It is considered problematic in this context that the findings on digital impression accuracy, regardless of whether teeth or implants have been scanned, are based almost exclusively on the results of in vitro studies. Conclusions about the accuracy of intraoral scanners under clinical conditions with moving patients and limited accessibility to the structures to be imaged, especially in the presence of blood, saliva or sulcus fluid, are extremely limited based on these data. Therefore, the aim of this study is to determine the clinical scanning accuracy of two current intraoral scanning systems for the three-dimensional acquisition of the position of two interforaminal dental implants in the edentulous mandible. The influence of artificial landmarks to achieve increased scan accuracy will also be tested.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT05032170
Study type Observational
Source University Hospital Heidelberg
Contact
Status Completed
Phase
Start date July 1, 2022
Completion date December 31, 2023

See also
  Status Clinical Trial Phase
Active, not recruiting NCT06408506 - In-patient Comparison of Immediately Loaded and Non-loaded Submerged and Transgingival Healed Implants Within 4 Months N/A
Active, not recruiting NCT05355792 - Multicenter Study to Evaluate the Clinical Outcome of the OmniTaper EV Implant in Single Tooth Restorations N/A
Terminated NCT00748670 - Treatment With Fixture Microthread™ in Patients With Poor Bone Quality and no Teeth in the Upper Jaw, When Using Two-Stage Surgery N/A
Completed NCT04873219 - Milled Versus Printed CAD/CAM Complete Dentures N/A
Active, not recruiting NCT04545840 - Prospective Neodent® Zirconia System Study
Completed NCT00922935 - Comparison of Early and Late Loading in the Edentulous Upper Jaw Using Cresco Prosthetic System on Straumann Implants Phase 4
Completed NCT00905840 - A Study to Treat Patients With Edentulous Mandibles With Two Straumann 3.3mm Diameter Bone Level Implants N/A
Completed NCT00959530 - Comparison of Lingualized and Full Bilaterally Balanced Articulation N/A
Completed NCT00711022 - Study on ASTRA TECH Implant System, OsseoSpeed™ Implants in Patients Missing All Teeth in the Upper Jaw, Restored With Provisional Teeth Within 24 Hours N/A
Terminated NCT00295126 - REPI : a Randomized Open Label Trial Evaluating the Use of APC in Pre-Implantation Reconstruction of Maxilla Phase 2/Phase 3
Recruiting NCT03957265 - Prospective Observational Study of SynCone® Concept Phase 1
Completed NCT01909999 - Release of Osteogenic Markers in Immediately and Non-loaded Dental Implants N/A
Completed NCT00901017 - Comparison of Synthetic Bone Substitute and a Bovine-derived Xenograft in Horizontal Bone Augmentation N/A
Completed NCT01641198 - An Implant With an Acid-etched Fixture Surface and Internal-hex Collar May Achieve Greater Osseointegration. N/A
Completed NCT03862482 - Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function N/A
Completed NCT01878331 - Long-term Study to Evaluate Different Dental Implant Alloys in Straumann 3.3mm Diameter Bone Level Implants
Completed NCT02418117 - Accuracy of Computer Guided Implant Surgery N/A
Completed NCT02107612 - Randomized Study For Minimally Invasive Splinted Implants N/A
Active, not recruiting NCT05007691 - Comparative Study of Maxillary and Mandibular Splints Used for the Treatment of Masticatory Muscle Parafunction (FEA) N/A
Active, not recruiting NCT04328116 - Study of Neodent Implantable Devices of GM Zygomatic Line