Clinical Trials Logo

Clinical Trial Summary

GM Zygomatic implant is intended to be surgically placed in the posterior region of the maxilla and zygoma. It is indicated for multiple prostheses in case of severe resorption in the maxilla and total edentulism (situations in which the installation of convectional implants is contraindicated). The objective of the study is to confirm the long-term safety and clinical performance of GM Zygomatic implants and GM Zygomatic abutments in daily dental practice setting, by means of a prospective collection of clinical data concerning the success and survival rates of these devices. Devices will be used according to standard routine in daily practice, according to all indications as specified by the manufacturer in the instructions for use (IFU). Ten patients will be followed for 36 months and monitored for Adverse Events by the Investigators until the last protocol-related procedure of a patient is completed.


Clinical Trial Description

The study protocol was reviewed and approved by an Ethics Committee (CE) in Brazil. GM Zygomatic implants present an optimized design with adapted treatment protocol, allowing for treatment of patients with severely resorbed maxilla and complete edentulism in which conventional implants placement is contraindicated. The objective of the study is to confirm the long-term safety and clinical performance of implants and abutments of GM Zygomatic System in a daily dental practice setting, by means of a prospective collection of clinical data in a study using these devices. Additionally, from the collected data, the study aims to identify previously unknown side-effects and monitor the known side-effects and contraindications stated on the Instructions for Use with the intent to verify that the intended purpose is adequate for all Neodent products involved in the procedure that come into contact with the patient. The sample will be prospectively selected and will consist of 10 patients with atrophic edentulous maxillae, for whom the responsible surgeon elects the rehabilitation by means of placement of zygomatic implants as having the best risk-benefit ratio for the patient (e.g., shorter treatment time and lower biological cost than the associated with reconstructive surgeries for the insertion of conventional implants). Informed consent in writing will be obtained from each patient participating in the study prior to any study-related procedure. Neodent GM Zygomatic implants will preferably be placed under local anesthesia and sedation (according to the surgeon's assessment of the patient's general health), with adequate bone bed preparation, as recommended by the manufacturer. Size, position, and quantity of implants (2 to 4) will be select considering the anatomy, region of rehabilitation, bone quality and quantity and available space. Together with the Zygomatic Implants, 2 to 4 conventional implants of Neodent GM line shall be inserted in the anterior region, if enough bone is available. Data concerning the studied variables will be collected following the procedures and assessments plan by fulfilling the Case Report Form (CRF), in the following stages: First visit (Screening); T0 - Implants placement; TF - final prosthesis (may coincide with TL); TL - Implant loading; T6, T12, T24 and T36 - 6, 12, 24 and 36 months, respectively, after implant placement. Computed tomography (CT) scans with prototyping will be obtained from the region of interest prior to surgery, for the surgical planning and implant selection, as well as post-surgery (T0 - immediately or within 1 week after implant placement; T36) to verify zygomatic implants anchorage. Prototypes of the region of interest in the maxilla will be obtained from the initial CT scans for diagnostic purposes. Additionally, standardized digital periapical radiographs will be taken in a usual daily practice frequency, as determined by the investigator: after implants placement (T0) and during the post-operative stages (TL, TF, T6, T12, T24, and T36) to assess the osseointegration process, changes in peri-implant bone level as well as prosthetic settlement and integrity. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04328116
Study type Observational
Source Neodent
Contact
Status Active, not recruiting
Phase
Start date July 15, 2020
Completion date March 2024

See also
  Status Clinical Trial Phase
Active, not recruiting NCT06408506 - In-patient Comparison of Immediately Loaded and Non-loaded Submerged and Transgingival Healed Implants Within 4 Months N/A
Active, not recruiting NCT05355792 - Multicenter Study to Evaluate the Clinical Outcome of the OmniTaper EV Implant in Single Tooth Restorations N/A
Terminated NCT00748670 - Treatment With Fixture Microthread™ in Patients With Poor Bone Quality and no Teeth in the Upper Jaw, When Using Two-Stage Surgery N/A
Completed NCT04873219 - Milled Versus Printed CAD/CAM Complete Dentures N/A
Active, not recruiting NCT04545840 - Prospective Neodent® Zirconia System Study
Completed NCT00922935 - Comparison of Early and Late Loading in the Edentulous Upper Jaw Using Cresco Prosthetic System on Straumann Implants Phase 4
Completed NCT00905840 - A Study to Treat Patients With Edentulous Mandibles With Two Straumann 3.3mm Diameter Bone Level Implants N/A
Completed NCT00959530 - Comparison of Lingualized and Full Bilaterally Balanced Articulation N/A
Completed NCT00711022 - Study on ASTRA TECH Implant System, OsseoSpeed™ Implants in Patients Missing All Teeth in the Upper Jaw, Restored With Provisional Teeth Within 24 Hours N/A
Terminated NCT00295126 - REPI : a Randomized Open Label Trial Evaluating the Use of APC in Pre-Implantation Reconstruction of Maxilla Phase 2/Phase 3
Recruiting NCT03957265 - Prospective Observational Study of SynCone® Concept Phase 1
Completed NCT01909999 - Release of Osteogenic Markers in Immediately and Non-loaded Dental Implants N/A
Completed NCT00901017 - Comparison of Synthetic Bone Substitute and a Bovine-derived Xenograft in Horizontal Bone Augmentation N/A
Completed NCT01641198 - An Implant With an Acid-etched Fixture Surface and Internal-hex Collar May Achieve Greater Osseointegration. N/A
Completed NCT03862482 - Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function N/A
Completed NCT01878331 - Long-term Study to Evaluate Different Dental Implant Alloys in Straumann 3.3mm Diameter Bone Level Implants
Completed NCT02418117 - Accuracy of Computer Guided Implant Surgery N/A
Completed NCT02107612 - Randomized Study For Minimally Invasive Splinted Implants N/A
Active, not recruiting NCT05007691 - Comparative Study of Maxillary and Mandibular Splints Used for the Treatment of Masticatory Muscle Parafunction (FEA) N/A
Completed NCT05032170 - Intraoral Scanning Accuracy in the Edentulous Mandible