Jaw, Edentulous Clinical Trial
Official title:
Release of Osteogenic Markers in Immediately and Non-loaded Dental Implants
Verified date | July 2013 |
Source | Paulista University |
Contact | n/a |
Is FDA regulated | No |
Health authority | Brazil: National Committee of Ethics in Research |
Study type | Interventional |
The aim of this study was to compare the release of the osteoprotegerin (OPG), transforming growth factors (TGF-α), osteocalcin (OCN), osteopontin (OPN), and parathyroid hormone (PTH) during osseointegration of dental implants with and without immediate loading. Forty patients were selected and randomly divided into: Group IM - implant and prosthesis placement within 72 hours; and Group NL - implant insertion and no prosthesis placement during 120 days. Peri-implant crevicular fluid (PICF) was collected immediately after implant insertion and with 7, 15, 30, 60, 90, and 120 days after surgery and were evaluated levels of OPG, TGF-α, OCN, OPN and PTH using Luminex assay. Clinical aspects (Sulcus bleeding and peri-implant probing depth) were also assessed. The data were compared using the ANOVA/Tukey and Friedman/Mann-Whitney tests (α=5%).
Status | Completed |
Enrollment | 40 |
Est. completion date | December 2012 |
Est. primary completion date | October 2012 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | Both |
Age group | 18 Years to 65 Years |
Eligibility |
Inclusion Criteria: - patients with mandibular and/or maxillary edentulous arch indicated for rehabilitation with dental implants - extractions had to occur at least 4 months prior to treatment - good oral hygiene (plaque index < 20%) (Ainamo & Bay, 1975) - age between 18-65 years Exclusion Criteria: - presence of systemic disease (including diabetes, arthritis, hypothyroidism, osteoporosis, etc) or use of medication (six months prior to the study) that contraindicated placement or alter implants osseointegration - use of anti-inflammatory three months before surgery - patients submitted to bone grafts in the site selected for the implant - pregnant or breastfeeding women - smokers or ex-smokers |
Allocation: Randomized, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Screening
Country | Name | City | State |
---|---|---|---|
Brazil | Faculty of Dentistry - Paulista University | São Paulo |
Lead Sponsor | Collaborator |
---|---|
Renato Correa Viana Casarin |
Brazil,
Brånemark PI, Engstrand P, Ohrnell LO, Gröndahl K, Nilsson P, Hagberg K, Darle C, Lekholm U. Brånemark Novum: a new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study. Clin Implant Dent Relat Res. 1999;1(1):2-16. — View Citation
Reile H, Birnböck H, Bernhardt G, Spruss T, Schönenberger H. Computerized determination of growth kinetic curves and doubling times from cells in microculture. Anal Biochem. 1990 Jun;187(2):262-7. — View Citation
Sato R, Matsuzaka K, Kokubu E, Inoue T. Immediate loading after implant placement following tooth extraction up-regulates cellular activity in the dog mandible. Clin Oral Implants Res. 2011 Dec;22(12):1372-8. doi: 10.1111/j.1600-0501.2010.02118.x. Epub 2011 Mar 8. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Ostegenic markers concentration | The collection of peri-implant crevicular fluid (PICF) was performed immediately after implant insertion (Baseline) and after 7, 15, 30, 60, 90 and 120 days. The site to be collected was dried and isolated with sterile gauze. PICF was collected at four sites per implant using absorbent paper strips (Periopaper, Oralflow, Smithtown, New York). The volume of fluid was measured immediately with the aid of Periotron (Oraflow, Smithtown, New York) and conditioned at 400uL of PBS buffer + 0.05% Tween and then frozen at -80°C. The levels of the peri-implant osteogenic markers (OPG, OCN, OPN, TGF-a, and PTH) were determined using the LUMINEX/Magpix system (HBN1A-51K and HCCBP1MAG-58K, Millipore Corporation, Billerica, MA, USA). The samples were analyzed individually and the levels were estimated using a 5-parameter polynomial curve in the Xponent® software (Millipore Corporation, Billerica, MA). The concentration values were expressed in pg/ml. |
The osteogenic markers were assessed immediatelly after implant installation until 120 days after prothesis instalation | No |
Secondary | Peri-implant sulcus depth (PISD) | The PISD parameter is part of the clinical examination done at implants included in this research. PISD was performed using a plastic probe (Colorvue, Hu-Friedy, Chicago, USA) by a single examiner (AJP), at the 2 most anterior implants in the protocol. For its determination 4 regions per implant - mesial-buccal (MB), mesial-lingual (ML), disto-buccal (DB) and disto-lingual (DL) regions - were used. The calibration of the examiner was performed on 2 different days, at least 24 hours apart, by peri-implant examination (peri-implant probing depth) in 10 non-participating subjects. The intraclass correlation index for this variable was 85%. The Peri-implant sulcus depth (PISD) was defined as: distance from the margin of the peri-implant mucosa to the bottom of the peri-implant sulcus; |
The PISD was assessed from 30 days after implants installation until 120 days after implant/prothesis installation | No |
Secondary | Modified Bleeding on Probing Index (MBPI) | The same examiner performing PISD did the Modified Bleeding on Probing Index, determined as the presence or absence of bleeding after 10 seconds on probing around implants. | The MPBI index was evaluated from 30 days after implants/prothesis installation and at 60, 90 and 120 days. | No |
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT06408506 -
In-patient Comparison of Immediately Loaded and Non-loaded Submerged and Transgingival Healed Implants Within 4 Months
|
N/A | |
Active, not recruiting |
NCT05355792 -
Multicenter Study to Evaluate the Clinical Outcome of the OmniTaper EV Implant in Single Tooth Restorations
|
N/A | |
Terminated |
NCT00748670 -
Treatment With Fixture Microthread™ in Patients With Poor Bone Quality and no Teeth in the Upper Jaw, When Using Two-Stage Surgery
|
N/A | |
Completed |
NCT04873219 -
Milled Versus Printed CAD/CAM Complete Dentures
|
N/A | |
Active, not recruiting |
NCT04545840 -
Prospective Neodent® Zirconia System Study
|
||
Completed |
NCT00922935 -
Comparison of Early and Late Loading in the Edentulous Upper Jaw Using Cresco Prosthetic System on Straumann Implants
|
Phase 4 | |
Completed |
NCT00905840 -
A Study to Treat Patients With Edentulous Mandibles With Two Straumann 3.3mm Diameter Bone Level Implants
|
N/A | |
Completed |
NCT00959530 -
Comparison of Lingualized and Full Bilaterally Balanced Articulation
|
N/A | |
Completed |
NCT00711022 -
Study on ASTRA TECH Implant System, OsseoSpeed™ Implants in Patients Missing All Teeth in the Upper Jaw, Restored With Provisional Teeth Within 24 Hours
|
N/A | |
Terminated |
NCT00295126 -
REPI : a Randomized Open Label Trial Evaluating the Use of APC in Pre-Implantation Reconstruction of Maxilla
|
Phase 2/Phase 3 | |
Recruiting |
NCT03957265 -
Prospective Observational Study of SynCone® Concept
|
Phase 1 | |
Completed |
NCT00901017 -
Comparison of Synthetic Bone Substitute and a Bovine-derived Xenograft in Horizontal Bone Augmentation
|
N/A | |
Completed |
NCT01641198 -
An Implant With an Acid-etched Fixture Surface and Internal-hex Collar May Achieve Greater Osseointegration.
|
N/A | |
Completed |
NCT03862482 -
Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function
|
N/A | |
Completed |
NCT01878331 -
Long-term Study to Evaluate Different Dental Implant Alloys in Straumann 3.3mm Diameter Bone Level Implants
|
||
Completed |
NCT02418117 -
Accuracy of Computer Guided Implant Surgery
|
N/A | |
Completed |
NCT02107612 -
Randomized Study For Minimally Invasive Splinted Implants
|
N/A | |
Active, not recruiting |
NCT05007691 -
Comparative Study of Maxillary and Mandibular Splints Used for the Treatment of Masticatory Muscle Parafunction (FEA)
|
N/A | |
Active, not recruiting |
NCT04328116 -
Study of Neodent Implantable Devices of GM Zygomatic Line
|
||
Completed |
NCT05032170 -
Intraoral Scanning Accuracy in the Edentulous Mandible
|