Clinical Trials Logo

Clinical Trial Summary

The Airtraq optical laryngoscope has recently been available in pediatric sizes. The investigators compared the efficacy of Airtraq with the Miller laryngoscope as intubation devices in paediatric patients. This prospective, randomized study was conducted in a tertiary care teaching hospital. Sixty American Society of Anesthesiologists (ASA) grade I-II paediatric patients of 2-10 years, posted for routine surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Miller (n = 30) or Airtraq (n = 30) laryngoscope. The primary outcome measures were time of intubation, ease of intubation, number of attempts and POGO score. We also measured hemodynamic changes and airway trauma.


Clinical Trial Description

After approval from the institutional Ethical Committee, 60 patients were studied. A randomised prospective study was planned to compare size 1 Airtraq (Prodol Meditec S.A., Vizcaya, Spain) with Miller blade of same size.

The children included in the study were 2-10 years of age, American Society of Anesthesiologists (ASA) physical status I-II and posted for elective surgeries requiring tracheal intubation. The following were excluded from the study: (i) patients with upper respiratory tract symptoms, (ii) those at risk of gastroesophageal regurgitation and (iii) those with airway-related conditions such a trismus, limited mouth opening, trauma or mass. Sixty patients were equally randomized to one of the two groups (Airtraq and Miller) of 30 each for airway management using a computer-generated randomization program.

Written informed consent was taken from the parents prior to intervention and a standardized protocol for anesthesia was maintained for all cases. All the children were kept nil per mouth as per standard guidelines. Intubation attempts were taken using Airtraq or Miller on a random basis. ;


Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Outcomes Assessor), Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT02423317
Study type Interventional
Source Government Medical College, Haldwani
Contact
Status Completed
Phase N/A
Start date May 2013
Completion date May 2014

See also
  Status Clinical Trial Phase
Completed NCT04994652 - Video- Or Direct Laryngoscopy for Endotracheal Intubation in Newborns N/A
Completed NCT03301324 - Intubation Assist Clinical Study N/A
Not yet recruiting NCT05534451 - Comparison Among Three Different Video Scope Guided Nasotracheal Intubation. N/A
Not yet recruiting NCT04116333 - Effect of Using Endotracheal Tube Introducer for Intubation During Mechanical Chest Compressions in a Manikin N/A
Recruiting NCT02001285 - Effect-site Concentration of Remifentanil for Blunting Hemodynamic Responses to Double-lumen Endobronchial Intubation N/A
Completed NCT02034643 - Transesophageal Echocardiography(TEE) Probe Insertion and Tracheal Cuff Pressure N/A
Completed NCT01718561 - The Difficult Airway Management Trial: "The DIFFICAIR-Trial" N/A
Completed NCT01227486 - Verification of Endotracheal Tube Placement by Ultrasound in the Obese Patient N/A
Withdrawn NCT01252173 - Measurement Of Endotracheal Tube Cuff Pressure In Emergency Department Patients N/A
Completed NCT04591769 - Tracheal Tube Cuff Shape and Pressure N/A
Completed NCT03841890 - The Clarus Video System and Direct Laryngoscope for Rapid Sequence Induction Intubation With Cricoid Pressure N/A
Recruiting NCT03716713 - CeraShield™ Endotracheal Tube Feasibility Study N/A
Not yet recruiting NCT03938506 - The Assessment of the Pilot Balloon Palpation Method in Different-sized Endotracheal Tubes
Not yet recruiting NCT01974505 - Learning Curve of Optiscope by Anesthesia Providers N/A
Completed NCT06107998 - Comparison of Different Methods for Determining Endotracheal Cuff Pressure N/A
Completed NCT02822846 - Evaluation of the Ability to Diagnose the Position of the Intubation Probe Thanks to Lung Ultrasonography
Completed NCT03116373 - Impact of Tracheal Tube Fixing Site on Its Mobility During Head Mobilization N/A
Not yet recruiting NCT04872881 - Comparison of Effectiveness of Different Airway Management Methods During Percutaneous Tracheostomy Phase 4
Completed NCT04863846 - Evidence-based Algorithm for the Expected Difficult Intubation
Terminated NCT03480425 - Force of Endotracheal Tube Extubation; Esophagus vs. Trachea N/A