Intubation; Difficult Clinical Trial
Official title:
Comparative Evaluation of Macintosh, MacCoy and Airtraq Laryngoscope in Simulated Difficult Laryngoscopy Using Rigid Neck Collar
Tracheal intubation requires alignment of oro-pharyngeal-laryngeal axes. When these three axes are not aligned, intubation becomes difficult. In the researchers' study, the investigators simulated difficult laryngoscopy situation by using a rigid neck collar. This neck collar renders intubation difficult not only by restricting neck movement, but also reducing mouth opening. The investigators compared the performance of Macintosh, MacCoy and Airtraq laryngoscope in simulated difficult laryngoscopy using a rigid neck collar.
Airtraq laryngoscope is an optical laryngoscope which allows visualization of vocal cord as a reflected image through multiple lenses and prisms. MacCoy laryngoscope is a modification of Macintosh laryngoscope. It has a lever which, when pressed, moves its flexible tip. In the investigators' study, the researchers compared the performances of Airtraq laryngoscope with MacCoy and Macintosh laryngoscopes in simulated difficult laryngoscopy using a rigid neck collar. The researchers recruited 120 patients and randomly divided those patients into three equal groups i.e. 30 patients in each group. These three groups are 1-Airtraq, 2-MacCoy and 3-Macintosh. The researchers compared efficacy and safety in these three laryngoscopes. The researchers compared efficacy in terms of time of intubation, ease of intubation, overall success, Intubation difficulty score, visualization of vocal cord in terms of POGO (percentage of Glottic Opening) score. The researchers compared safety in terms of hemodynamic pressor response and airway trauma. ;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Outcomes Assessor), Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT02922595 -
Comparison of iLTS-D® and ILMA® for Intubation With Fiberoptic Control
|
N/A | |
Completed |
NCT02051400 -
Evaluation of McGrath® MAC Video Laryngoscope
|
N/A | |
Completed |
NCT01965938 -
RIFL (Rigid and Flexing Laryngoscope) vs. Fiberoptic Bronchoscope
|
N/A | |
Completed |
NCT02769819 -
Identification of Morphological Characteristics to Predict Difficult Endotracheal Intubation Using a Flexible Fiberscope
|
N/A | |
Completed |
NCT02362568 -
Study of Interest on Cervical Ultrasound Exploration for Association With Difficult Intubation
|
N/A | |
Completed |
NCT01692522 -
Comparison of the Laryngeal Mask Ambu Aura-i Versus AirQ in Children
|
N/A | |
Recruiting |
NCT03035786 -
Airway Code Calls - Survey of Management
|
N/A | |
Completed |
NCT02290249 -
Intubation of a Pediatric Manikin in Difficult Airway by Novice Personnel: A Comparison of Glidescope and Airtraq
|
Phase 4 | |
Completed |
NCT01984970 -
McGrath Series 5 Videolaryngoscope for Double-lumen Tube Intubation
|
N/A | |
Completed |
NCT02326896 -
MACOCHA Score Predicts Intubation Failure
|
N/A | |
Completed |
NCT01474213 -
Sedation Effect of Dexmedetomidine Versus Remifentanil to Fibreoptic Intubation
|
Phase 4 | |
Terminated |
NCT00464490 -
Use of Dexmedetomidine to Facilitate Extubation in Surgical ICU Patients Who Failed Previous Weaning Attempts
|
N/A | |
Not yet recruiting |
NCT02430415 -
Laryngoscope-assisted Lightwand Intubation and Cervical Spine Motion
|
N/A | |
Completed |
NCT01375634 -
Nasogastric Tube Insertion Using Midazolam in the Emergency Department
|
Phase 4 | |
Completed |
NCT01464489 -
Intubation Time With Low Dose Rocuronium
|
N/A | |
Terminated |
NCT01075789 -
Using Lignocaine Spray and Gel to Reduce the Pain Associated With Nasogastric Tube Insertion in Children
|
N/A | |
Recruiting |
NCT02501577 -
Comparison of Various Supraglottic Airway Devices for Fiberoptical Guided Tracheal Intubation
|
N/A | |
Completed |
NCT02566135 -
I-gel Versus Classic-Laryngeal Mask Airway (C-LMA) as a Conduit for Tracheal Intubation Using Ventilating Bougie
|
N/A | |
Recruiting |
NCT02493478 -
Improving Safety and Quality of Tracheal Intubation Practice in Pediatric ICUs
|
||
Completed |
NCT02198742 -
A Comparison Between Two Video Laryngoscopes,in Successfully Intubating Pediatric Mannequins w/wo Difficult Airways
|
Phase 1 |