Intubation; Difficult Clinical Trial
— C-MACOfficial title:
Initial Experience With Storz C-MAC Video Intubation System
Verified date | October 2021 |
Source | The University of Texas Health Science Center, Houston |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The purpose of this study is to determine the safety and efficacy of the C-MAC (Karl Storz Endoscopy, Inc., Tuttlingen, Germany) video intubation system guided intubation techniques. We hypothesize that the C-MAC video laryngoscope is safe and efficacious in terms of successful endotracheal intubation. The C-MAC may be a safe and suitable alternative device for routine and difficult laryngoscopy and tracheal intubation. This is the first study to investigate the performance of C-MAC in clinical practice.
Status | Completed |
Enrollment | 50 |
Est. completion date | February 2012 |
Est. primary completion date | September 2010 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 18 Years to 80 Years |
Eligibility | Inclusion Criteria: - Age 18 - 80 years of age - ASA I - III - Mallampati I-III - Mouthopening > 4cm Exclusion Criteria: - Age < 18 years and > 80 years of age - ASA IV - V - Mallampati IV - V - Mouthopening < 4cm |
Country | Name | City | State |
---|---|---|---|
United States | Memorial Hermann Hospital | Houston | Texas |
Lead Sponsor | Collaborator |
---|---|
The University of Texas Health Science Center, Houston |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Time for Intubation | Time taken for successful placement of endotracheal tube (that is, intubation). | at the time of intubation (about 10 seconds) | |
Secondary | Laryngoscopy Time | Laryngoscopy time is defined as the time between advancing the laryngoscopy and obtaining the optimal view of the airway. | at the time of laryngoscopy (about 10 seconds) | |
Secondary | Airway View at the Time of Laryngoscopy as Categorized by the Modified Cormack-Lehane Classification (Before External Manipulation) | Modified Cormack-Lehane classification:
Full view of glottis a Partial view of glottis 2b Only posterior extremity of glottis seen or only arytenoid cartilages 3 Only epiglottis seen, none of glottis seen 4 Neither glottis nor epiglottis seen |
at the time of laryngoscopy (about 10 seconds) | |
Secondary | Airway View at the Time of Laryngoscopy as Categorized by the Modified Cormack-Lehane Classification (After External Manipulation) | Modified Cormack-Lehane classification:
Full view of glottis a Partial view of glottis 2b Only posterior extremity of glottis seen or only arytenoid cartilages 3 Only epiglottis seen, none of glottis seen 4 Neither glottis nor epiglottis seen |
at the time of laryngoscopy (about 10 seconds) | |
Secondary | Number of Participants With Successful Intubation | at the time of intubation (about 10 seconds) | ||
Secondary | Ease of Intubation as Assessed by a Rating Scale | Ease of intubation as assessed by a rating scale, which ranged from 1 (very easy) to 5 (very difficult). | at the time of intubation (about 10 seconds) | |
Secondary | Ease of Laryngoscopy as Assessed by a Rating Scale | Ease of laryngoscopy as assessed by a rating scale, which ranged from 1 (very easy) to 5 (very difficult). | at the time of laryngoscopy (about 10 seconds) |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT02922595 -
Comparison of iLTS-D® and ILMA® for Intubation With Fiberoptic Control
|
N/A | |
Completed |
NCT02051400 -
Evaluation of McGrath® MAC Video Laryngoscope
|
N/A | |
Completed |
NCT01965938 -
RIFL (Rigid and Flexing Laryngoscope) vs. Fiberoptic Bronchoscope
|
N/A | |
Completed |
NCT02769819 -
Identification of Morphological Characteristics to Predict Difficult Endotracheal Intubation Using a Flexible Fiberscope
|
N/A | |
Completed |
NCT02362568 -
Study of Interest on Cervical Ultrasound Exploration for Association With Difficult Intubation
|
N/A | |
Completed |
NCT01692522 -
Comparison of the Laryngeal Mask Ambu Aura-i Versus AirQ in Children
|
N/A | |
Recruiting |
NCT03035786 -
Airway Code Calls - Survey of Management
|
N/A | |
Completed |
NCT02290249 -
Intubation of a Pediatric Manikin in Difficult Airway by Novice Personnel: A Comparison of Glidescope and Airtraq
|
Phase 4 | |
Completed |
NCT02326896 -
MACOCHA Score Predicts Intubation Failure
|
N/A | |
Completed |
NCT01984970 -
McGrath Series 5 Videolaryngoscope for Double-lumen Tube Intubation
|
N/A | |
Completed |
NCT01474213 -
Sedation Effect of Dexmedetomidine Versus Remifentanil to Fibreoptic Intubation
|
Phase 4 | |
Terminated |
NCT00464490 -
Use of Dexmedetomidine to Facilitate Extubation in Surgical ICU Patients Who Failed Previous Weaning Attempts
|
N/A | |
Not yet recruiting |
NCT02430415 -
Laryngoscope-assisted Lightwand Intubation and Cervical Spine Motion
|
N/A | |
Completed |
NCT01375634 -
Nasogastric Tube Insertion Using Midazolam in the Emergency Department
|
Phase 4 | |
Completed |
NCT01464489 -
Intubation Time With Low Dose Rocuronium
|
N/A | |
Terminated |
NCT01075789 -
Using Lignocaine Spray and Gel to Reduce the Pain Associated With Nasogastric Tube Insertion in Children
|
N/A | |
Recruiting |
NCT02501577 -
Comparison of Various Supraglottic Airway Devices for Fiberoptical Guided Tracheal Intubation
|
N/A | |
Completed |
NCT02566135 -
I-gel Versus Classic-Laryngeal Mask Airway (C-LMA) as a Conduit for Tracheal Intubation Using Ventilating Bougie
|
N/A | |
Recruiting |
NCT02493478 -
Improving Safety and Quality of Tracheal Intubation Practice in Pediatric ICUs
|
||
Completed |
NCT02198742 -
A Comparison Between Two Video Laryngoscopes,in Successfully Intubating Pediatric Mannequins w/wo Difficult Airways
|
Phase 1 |