Intubation Complication Clinical Trial
Official title:
Comparison of C-Mac D Blade and Fastrach Laryngeal Mask Airway on Cervical Spine Motion Conditions in Cervical Discectomy
In patients with cervical spine disorders or hernia, in-line stabilization and immobilization during tracheal intubation is used to avoid neck injury. With direct laryngoscopy cranio-cervical motion can result injury. The aim of the study is to compare two different device (C-Mac D blade versus fastrach LMA ) regarding cervical motions during intubation.
In simulated or clinical settings of restricted neck mobility, videolaryngoscopes and fastrach LMA have performed well but neck motion can be occured. Endotracheal intubation will be performed under fluoroscopy. In this study the neck motion angles will be investigated during intubation . The angles will be assessed on fluoroscopy images. A Angle: Angle of the line between occipital protuberance and anterior process of the foramen magnum with the line between central point of spinous process C1 vertebrae and the anterior process of foramen magnum. The reference line for the occiput is defined as a line between the base of the sella and the opisthion (lineA), and the C1 reference line as a line between the lower cortical margin of the spinous process (line B). The C2 reference line is defined as a line between the anterior , inferior margin of the C2 body and the lower cortical margin of the C2 spinous process (lineC). The C5 reference line is a tangent along the superior endplate of the C5 vertebral body (line D). The groups will be compared statistically. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT05717907 -
Suction Catheter as a Guide for Nasotracheal Intubation Under General Anesthesia
|
N/A | |
Completed |
NCT03653910 -
Effect-site Concentration of Remifentanil for Double-lumen Tubes Intubation: Airtraq VS Macintosh Laryngoscope
|
N/A | |
Recruiting |
NCT04190524 -
Sonographic Assessment of Cricoid Pressure
|
N/A | |
Completed |
NCT02359370 -
The Effects of Lidocaine and Magnesium Sulphate on the Attenuation of the Hemodynamic Response to Tracheal Intubation
|
Phase 4 | |
Not yet recruiting |
NCT05036460 -
Real-time Sonography in Detecting Inadvertent Esophageal Intubation Among Difficult Intubation Patients
|
N/A | |
Completed |
NCT05502120 -
A Comparison of Vie-Scope and Macintosh Blade Laryngoscopes in Morbidly Obese.
|
N/A | |
Completed |
NCT03992950 -
Effectiveness of Cricoid and Paratracheal Pressures for Occluding Esophagus
|
N/A | |
Completed |
NCT05303948 -
Evaluation of Two Positions for Free Floating Tracheal Intubation in Weightlessness
|
N/A | |
Completed |
NCT03720093 -
Exploratory Analysis of Pulmonary Microbiome in Intubated Patients
|
||
Recruiting |
NCT03031808 -
Comparison of Two Induction Regimens Using Topical Lidocaine or Muscle Relaxant on Sore Throat and Hemodynamics
|
Phase 4 | |
Not yet recruiting |
NCT02918526 -
Hemodynamic Study With PRAM of the Cardiovascular Response to the Positioning of the Extraglottic Device
|
N/A | |
Completed |
NCT02364622 -
The Effects of Flexible Intubating Stylet in the Accurate Placement of Double-lumen Endobronchial Tube
|
N/A | |
Completed |
NCT05249738 -
Tongue Edema Caused by Intubation Tube in Intensive Care Unit Patients
|
||
Terminated |
NCT03340207 -
Novel Airway Device to Aid Endotracheal Intubations
|
N/A | |
Completed |
NCT03842306 -
End-tidal Oxygen Can Reliably Predict the Arterial Partial Pressure of Oxygen Among Emergency Department Patients
|
||
Recruiting |
NCT05782517 -
I-gel vs. Endotracheal Intubation for Laparoscopic Gynaecological Procedures
|
N/A | |
Recruiting |
NCT06085326 -
Smart Checklist Implementation for Pediatric Tracheal Intubations in the ICU- Multicenter Study
|
N/A | |
Active, not recruiting |
NCT06108271 -
Innovative Endotracheal Tube Design Reduces Postoperative Laryngeal Injury
|
N/A | |
Completed |
NCT05668299 -
Determining the Appropriate Setting of an Automated Secretion Removal Technology (TrachFlush)
|
N/A | |
Completed |
NCT04079387 -
Effect of Endotracheal Tube Plus STYLET Versus Endotracheal Tube Alone
|
N/A |