Intraocular Pressure Clinical Trial
Official title:
The Effect of the Steep Trendelenburg Position on Intraocular Pressure ın Patients Undergoing Total Laparoscopic Hysterectomy
A total of 50 patients aged between 18-60 years, classified as American Society of Anesthesiologists (ASA) I-II, undergoing elective total laparoscopic hysterectomy in the steep trendelenburg position (STP) will be included in the study. Preoperatively, an ophthalmologist will perform an eye examination on the patients, and intraocular pressure will be measured using a non-contact computerized tonometer (Topcon CT-800, Japan). Central corneal thickness and iridocorneal angle will be measured using a topography device (Sirius Topography, CSO, Italy), and the thickness of the retinal nerve fiber layer (RNFL) will be measured using an optical coherence tomography (OCT) device (DRI OCT Triton, Topcon, Japan). Patients' demographic data and operation durations will be recorded. Intraocular pressure (IOP) will be measured in the supine position after intubation (T1), during pneumoperitoneum (T2), in the steep Trendelenburg position (23°, head down) (T3), at the end of the operation when pneumoperitoneum is terminated (T4), after returning to the supine position (T5), and 10 minutes after returning to the supine position (T6). Simultaneously with IOP measurements, the patients' hemodynamic data (Blood pressure, heart rate, end-tidal CO2, partial saturation) will be recorded.
This study is planned to be conducted in the operating room of Kartal Dr. Lütfi Kırdar City Hospital between June 2024 and July 2024. A total of 50 patients aged between 18-60 years, classified as ASA I-II, undergoing elective total laparoscopic hysterectomy in the steep Trendelenburg position will be included in the study. Patients who are under 18 years or over 60 years, classified as ASA III or above, or have pre-existing eye conditions causing intraocular pressure changes such as glaucoma or ocular hypertension, cranial tumors, or any conditions that may be affected by increased intracranial pressure will not be included in the study. All patients will undergo a preoperative evaluation the day before surgery, and written informed consent will be obtained for participation in the study. Patients who agree to participate will have an eye examination performed by an ophthalmologist preoperatively. Intraocular pressure (IOP) will be measured using a non-contact computerized tonometer (Topcon CT-800, Japan). Central corneal thickness and iridocorneal angle will be measured using a topography device (Sirius Topography, CSO, Italy), and the thickness of the retinal nerve fiber layer (RNFL) will be measured using an optical coherence tomography (OCT) device (DRI OCT Triton, Topcon, Japan). Sure, here is the translation of your text into English: --- The anesthesia protocol will be standardized for the drugs used during the procedure. Standard anesthesia induction will be provided with 2 mg IV midazolam, 3 mg/kg IV propofol, 100 mcg IV fentanyl, and 0.8 mg/kg IV rocuronium. Sevoflurane at 1 Minimum Alveolar Concentration (MAC) will be used for anesthesia maintenance. While the patient is in the supine position, intraperitoneal CO2 insufflation will be used to create pneumoperitoneum. The patients will then be placed in the steep Trendelenburg position (25 degrees from horizontal) at the maximum Trendelenburg angle (STP). All procedures will be performed in the same operating room, on the same table, and at the same angle. Intraperitoneal pressure will be maintained at 15 mm Hg throughout the surgery. At the end of the operation, patients will be awakened and transferred to the recovery unit. In the recovery unit, patients will be monitored for at least 30 minutes. Intraocular pressure (IOP) will be measured in the supine position using a contact handheld tonometer (TONO-PEN AVIA, Reichert, USA). The Tono-pen is chosen for its speed, the ability to measure across multiple patients with single-use latex tip covers, ease of use, accuracy, and reliability in various positions. Five consecutive measurements will be taken for each eye. If the variability between consecutive measurements exceeds 5%, the measurements will be repeated. The average of the five measurements will be taken for each measurement. All measurements will be performed by the same ophthalmologist. All surgical operations will be conducted in the morning or early afternoon to prevent diurnal variations in IOP. All surgeries will be performed by the same surgical team. The demographic data of the patients and the durations of the operations will be recorded. IOP will be measured in the supine position after intubation (T1), during pneumoperitoneum (T2), when placed in STP (23° head down) (T3), at the end of the operation when pneumoperitoneum is terminated (T4), after being placed back in the supine position (T5), and 10 minutes after being placed back in the supine position (T6). Simultaneously with IOP measurements, the patients' hemodynamic data (blood pressure, heart rate, end-tidal CO2, partial saturation) will be recorded. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT03016234 -
IOP Changes With Different Anesthetic Agents During Laparoscopic Colorectal Surgery
|
N/A | |
Completed |
NCT04863209 -
Effect of Osteopathic Techiniques on Intraocular Pressure
|
N/A | |
Completed |
NCT03139708 -
The Effect of Brimonidine on Intraocular Pressure When Dilating Routine Patients
|
Phase 1 | |
Completed |
NCT02646033 -
Quantitative Rise in Intraocular Pressure in Steep Trendelenburg Position
|
||
Recruiting |
NCT02697825 -
Intraocular Pressure Versus Optic Nerve Sheath Diameter
|
N/A | |
Completed |
NCT02985567 -
An Observational Study of the Use of Chloral Hydrate for Ophthalmic Procedures in Children
|
N/A | |
Withdrawn |
NCT00837226 -
Effects of Weight Loss From Bariatric Surgery on Intraocular Pressure (IOP)
|
N/A | |
Completed |
NCT02136589 -
Effect of NSAID on Travoprost-induced Conjunctival Hyperemia and IOP Reduction in Normal Eyes
|
Phase 4 | |
Completed |
NCT03123614 -
Loteprednol vs. Prednisolone and Fluorometholone
|
Phase 4 | |
Completed |
NCT05763056 -
Effects of Intubation on Intra-ocular Pressure and Optic Nerve Sheath Diameter
|
N/A | |
Completed |
NCT03359200 -
Analysis of the Microbiota in Goldmann Applanation Tonometers at a Reference Service in Goiânia
|
N/A | |
Completed |
NCT02816905 -
Ocular-hypertensive Response to Topical Steroids in Children After Bilateral Strabismus Surgery
|
Phase 4 | |
Withdrawn |
NCT02558309 -
Optic Nerve Head Quantification While Reducing Elevated Intracranial Pressure
|
N/A | |
Completed |
NCT01786954 -
iCare vs Tonopen vs Goldmann Applanation Post-vitrectomy Surgery
|
N/A | |
Completed |
NCT00552019 -
Intraocular Pressure (IOP) Assessed by Dynamic Contour Tonometer (DCT) and Goldman Applanation Tonometry (GAT)
|
N/A | |
Completed |
NCT00428740 -
Long-Term IOP Fluctuation and VF Progression After Triple Procedure
|
N/A | |
Completed |
NCT04360369 -
Comparison of Intraocular Pressure Measurements Between Reichert Tono-Vera Tonometer and Goldmann Tonometry
|
N/A | |
Completed |
NCT04521140 -
Assessing eFficacy and Safety of DEXTENZA 0.4 mg inseRt, Following Corneal Transplant Surgery
|
Phase 4 | |
Completed |
NCT05167773 -
Clinical Study of the Topcon Tonometer TRK-3
|