Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03016507
Other study ID # VEREO 3
Secondary ID
Status Completed
Phase N/A
First received January 6, 2017
Last updated January 6, 2017
Start date July 2015
Est. completion date January 2017

Study information

Verified date January 2017
Source VER Excelência em Oftalmologia
Contact n/a
Is FDA regulated No
Health authority Brazil: Ethics Committee
Study type Observational

Clinical Trial Summary

The objective of this study is to evaluate the IOP variation before and 30 days after performing phacoemulsification through pneumatic tonometry, in addition to evaluating the factors possibly related to this variation.


Description:

Cataracts represent the major cause of treatable blindness in developing countries. According to data , there are 45 million blind people in the world, of which 40% is due to cataract etiology. In Brazil, there are about 350,000 individuals blinded by cataracts.

One of the consequences observed after the cataract surgery is the variation of intraocular pressure (IOP). IOP is directly related to the volume of aqueous humor in the anterior chamber. Reports of oscillations after a cataract surgery range from +1.3 to -2.5 mmHg. The duration of this oscillation varies according to the literature studied. Some studies show that the oscillation seen in the first postoperative year was maintained for the 10-year period and was similar in patients of all ages. However, other authors have identified a non-permanent oscillation, which makes this topic controversial in ophthalmology.

There are a number of factors related to the degree of IOP reduction after a cataract surgery. Studies have shown that the preoperative IOP value, the depth of the anterior chamber, the volume of irrigation used during surgery and the age of the patients may interfere with the IOP variation in the postoperative period.

However, the gold standard tonometer for IOP measurement is Goldmann's. This measurement is closely related to important characteristics of the cornea, such as its thickness and curvature, and may underestimate or overestimate IOP values.

Another way to measure IOP is through a non-contact tonometer, blow or pneumatic. The blow tonometer has a pneumatic system that produces a jet of air, which leads to flattening of the cornea and on the surface of which a beam of parallel light rays is projected, in which only the reflected parallel and coaxial rays are picked up by the receiver of the device, obtaining a maximum peak of light reception when the cornea is flattened. Its main advantage is in its use in screening programs, the need for the use of eye drops and the lowest rates of contamination. The blow tonometer, as well as the flattening tonometer, is influenced by corneal factors, such as curvature and thickness, presenting the same parameters of under and overestimation of IOP.

The objective of this study is to evaluate the IOP variation before and 30 days after performing phacoemulsification through pneumatic tonometry, in addition to evaluating the factors possibly related to this variation.


Recruitment information / eligibility

Status Completed
Enrollment 100
Est. completion date January 2017
Est. primary completion date January 2017
Accepts healthy volunteers No
Gender All
Age group 18 Years to 80 Years
Eligibility Inclusion Criteria:

- older than 18 years

- deep anterior chamber visualized by the slit lamp with open angle estimation using the Van Herick technique

- IOP lower than 21 mmHg

- without surgical intercurrences, submitted to phacoemulsification

Exclusion Criteria:

- younger than 18 years

- shallow anterior chamber visualized by slit lamp with estimation of narrow angle

- preoperative surgical complications

- IOP greater than 21 mmHg

- contact lens wearers

- eye surgeries and/or ocular diseases and/or systemic disorders.

Study Design

Time Perspective: Cross-Sectional


Related Conditions & MeSH terms


Locations

Country Name City State
Brazil Rodrigo Egidio da Silva Goiania GO

Sponsors (2)

Lead Sponsor Collaborator
VER Excelência em Oftalmologia Francisco Welington Rodrigues

Country where clinical trial is conducted

Brazil, 

References & Publications (8)

Bigger JF, Becker B. Cataracts and primary open-angle glaucoma: the effect of uncomplicated cataract extraction on glaucoma control. Trans Am Acad Ophthalmol Otolaryngol. 1971 Mar-Apr;75(2):260-72. — View Citation

Damji KF, Konstas AG, Liebmann JM, Hodge WG, Ziakas NG, Giannikakis S, Mintsioulis G, Merkur A, Pan Y, Ritch R. Intraocular pressure following phacoemulsification in patients with and without exfoliation syndrome: a 2 year prospective study. Br J Ophthalmol. 2006 Aug;90(8):1014-8. — View Citation

Poley BJ, Lindstrom RL, Samuelson TW, Schulze R Jr. Intraocular pressure reduction after phacoemulsification with intraocular lens implantation in glaucomatous and nonglaucomatous eyes: evaluation of a causal relationship between the natural lens and open-angle glaucoma. J Cataract Refract Surg. 2009 Nov;35(11):1946-55. doi: 10.1016/j.jcrs.2009.05.061. — View Citation

Poley BJ, Lindstrom RL, Samuelson TW. Long-term effects of phacoemulsification with intraocular lens implantation in normotensive and ocular hypertensive eyes. J Cataract Refract Surg. 2008 May;34(5):735-42. doi: 10.1016/j.jcrs.2007.12.045. — View Citation

Shingleton BJ, Pasternack JJ, Hung JW, O'Donoghue MW. Three and five year changes in intraocular pressures after clear corneal phacoemulsification in open angle glaucoma patients, glaucoma suspects, and normal patients. J Glaucoma. 2006 Dec;15(6):494-8. — View Citation

Slabaugh MA, Bojikian KD, Moore DB, Chen PP. The effect of phacoemulsification on intraocular pressure in medically controlled open-angle glaucoma patients. Am J Ophthalmol. 2014 Jan;157(1):26-31. doi: 10.1016/j.ajo.2013.08.023. — View Citation

Vincent SJ, Vincent RA, Shields D, Lee GA. Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients. Clin Exp Ophthalmol. 2012 May-Jun;40(4):e163-70. doi: 10.1111/j.1442-9071.2011.02670.x. — View Citation

Yang HS, Lee J, Choi S. Ocular biometric parameters associated with intraocular pressure reduction after cataract surgery in normal eyes. Am J Ophthalmol. 2013 Jul;156(1):89-94.e1. doi: 10.1016/j.ajo.2013.02.003. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Intraocular Pressure Variation by Pneumatic Tonometer Before and After Phacoemulsification Six months No
See also
  Status Clinical Trial Phase
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT03016234 - IOP Changes With Different Anesthetic Agents During Laparoscopic Colorectal Surgery N/A
Completed NCT04863209 - Effect of Osteopathic Techiniques on Intraocular Pressure N/A
Completed NCT03139708 - The Effect of Brimonidine on Intraocular Pressure When Dilating Routine Patients Phase 1
Completed NCT02646033 - Quantitative Rise in Intraocular Pressure in Steep Trendelenburg Position
Recruiting NCT02697825 - Intraocular Pressure Versus Optic Nerve Sheath Diameter N/A
Completed NCT02985567 - An Observational Study of the Use of Chloral Hydrate for Ophthalmic Procedures in Children N/A
Withdrawn NCT00837226 - Effects of Weight Loss From Bariatric Surgery on Intraocular Pressure (IOP) N/A
Completed NCT02136589 - Effect of NSAID on Travoprost-induced Conjunctival Hyperemia and IOP Reduction in Normal Eyes Phase 4
Completed NCT03123614 - Loteprednol vs. Prednisolone and Fluorometholone Phase 4
Completed NCT05763056 - Effects of Intubation on Intra-ocular Pressure and Optic Nerve Sheath Diameter N/A
Completed NCT03359200 - Analysis of the Microbiota in Goldmann Applanation Tonometers at a Reference Service in Goiânia N/A
Completed NCT02816905 - Ocular-hypertensive Response to Topical Steroids in Children After Bilateral Strabismus Surgery Phase 4
Withdrawn NCT02558309 - Optic Nerve Head Quantification While Reducing Elevated Intracranial Pressure N/A
Completed NCT01786954 - iCare vs Tonopen vs Goldmann Applanation Post-vitrectomy Surgery N/A
Completed NCT00552019 - Intraocular Pressure (IOP) Assessed by Dynamic Contour Tonometer (DCT) and Goldman Applanation Tonometry (GAT) N/A
Completed NCT00428740 - Long-Term IOP Fluctuation and VF Progression After Triple Procedure N/A
Completed NCT04360369 - Comparison of Intraocular Pressure Measurements Between Reichert Tono-Vera Tonometer and Goldmann Tonometry N/A
Completed NCT04521140 - Assessing eFficacy and Safety of DEXTENZA 0.4 mg inseRt, Following Corneal Transplant Surgery Phase 4
Completed NCT05167773 - Clinical Study of the Topcon Tonometer TRK-3