Clinical Trials Logo

Clinical Trial Summary

Neurally Adjusted Ventilatory Assist (NAVA) is a mode of ventilation where the electrical activity of the diaphragm (EDI) - a signal representing the baby's respiratory drive - is used to control the timing and amount of assist provided. NAVA was introduced to the market in 2007 and since has been used in more than 40 countries. In the current clinical practice, the Edi signal from the patient is captured with miniature sensors (the size of a hair) embedded in the wall of a specially designed naso/orogastric feeding tube. This FDA and Health Canada approved, commercially available catheter (Getinge, Solna, Sweden), is 6 Fr in size (outer diameter), 49 cm in length and has 8 pairs of sensors that are placed 6 mm apart (so-called inter electrode distance (IED) is 6 mm). While no obvious side effects have been noted by clinicians, for the smallest of neonates, the currently used commercial catheter (size 6F, 49 cm long) may have 'excessive' post-array catheter length. In these neonates, typically those with weight < 750 grams, following the correct placement of catheter as per the electrode array positioning at gastro-esophageal junction, the feeding holes in the catheter may end at the level of distal stomach instead of the desirable mid-stomach location. The changing demographics of the patients in the Neonatal Intensive Care Units (NICU) has created a clinical need to redesign the currently used Edi catheter specifically to suit the smallest of patients, such that following adequate placement the feeding holes sit at the level of mid-stomach. Drs. Christer Sinderby and Jennifer Beck in Toronto, Canada, are the original designers of the 6 mm/49 cm currently used Edi catheter. These investigators (at St-Michael's Hospital, Toronto) in collaboration with their team at Neurovent Research Inc. (NVR) have re-designed and invented a new prototype of the current FDA-approved catheter specifically suited for use in extreme premature neonates. They have done so by reducing the interelectrode distance from the originally set 6 mm to 4 mm, which reduces the overall insertion depth to capture the same signal from the diaphragm. All other parameters are exactly same as the original catheter (6F, 49 cm long). In this small feasibility study the investigators wish to provide a clinical proof of concept for the use of this newly designed prototype in 10 extremely premature neonates who are already receiving NAVA ventilation in the NICU.


Clinical Trial Description

This is an unblinded pilot study to evaluate the performance of the new 4 mm IED. The procedures required for this evaluation include placement of the new NVR 4 mm Edi catheter, and ventilation in the NAVA mode. All these procedures are considered to have no significant additional risk. Supervision by a physician or respiratory therapist with expertise in Edi catheter and NAVA will be present, in line with the current clinical practice in the Mount Sinai NICU. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05427929
Study type Interventional
Source Mount Sinai Hospital, Canada
Contact Amish Jain, MD, PhD
Phone 416-586-4800
Email amish.jain@sinaihealth.ca
Status Recruiting
Phase N/A
Start date January 12, 2023
Completion date June 2024

See also
  Status Clinical Trial Phase
Completed NCT03146351 - The Effects of Family Centered Intervention Program on Preterm Infants N/A
Completed NCT02064712 - Determining an Optimal Weaning Method of Nasal Continuous Positive Airway Pressure in Preterm Neonates N/A
Completed NCT00365703 - Nasogastric Tube vs. Orogastric Feeding Tube in Preterm Infants: Which is Best? N/A
Terminated NCT00179933 - The Impact of Implementing NIDCAP on Preterm Infants in the NICU N/A
Completed NCT00114543 - Trial of Aggressive Versus Conservative Phototherapy in Infants <1,000 Grams Birth Weight Phase 3
Terminated NCT05030012 - Maintaining Optimal HVNI Delivery Using Automatic Titration of Oxygen in Preterm Infants N/A
Completed NCT00552383 - The Edmonton Randomised Controlled Trial of NIDCAP - Based Developmental Care N/A
Completed NCT00011362 - Dexamethasone Therapy in VLBW Infants at Risk of CLD Phase 3
Completed NCT06308471 - Effect of Baby Massage on Oral Motor Skills of Premature Babies N/A
Completed NCT01863043 - Aspiration of Residual Gastric Contents N/A
Completed NCT05462509 - Feasibility of Use of the PATH bCPAP and Oxygen Blenders Device With Neonates in Uganda N/A
Not yet recruiting NCT06109350 - The Effect of Physical Therapy Intervention on Motor Performance in Bhutanese Preterm Infants N/A
Completed NCT03551600 - Splanchnic and Renal Tissue Oxygenation During Enteral Feedings in Neonates With Patent Ductus Arteriosus
Terminated NCT02599545 - Testosterone and Cortisol Levels in Infants
Completed NCT02611284 - Less Invasive Beractant Administration in Preterm Infants N/A
Completed NCT01193270 - Vitamin E for Extremely Preterm Infants Phase 1
Completed NCT00455169 - Influenza Vaccine in Premature Infants Phase 4
Withdrawn NCT00536445 - Use of NAVA in Intubated Preterm Phase 1/Phase 2
Completed NCT00579553 - Comparing IM vs. Vaginal Progesterone for Pre-term Birth N/A
Completed NCT01203423 - Persistent Pulmonary Hypertension of the Newborn (PPHN) Observational Study