Indirect Calorimetry Clinical Trial
Official title:
Assessing the Appropriate Energy Expenditure Requirement Using Indirect Calorimetry for Liver Transplant Recipients
Verified date | August 2018 |
Source | Asan Medical Center |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational |
Although predicted REE calculated using the Penn state 1988 method agreed (ICC 0.61,
p=0.00014) with the measured REE, all three predictive equations had a fixed bias and
appeared to be inaccurate for predicting REE for liver transplant recipients.
Therefore, precise measurements using indirect calorimetry may be helpful when treating
critically ill patients to avoid underestimating or overestimating their metabolic needs.
Status | Completed |
Enrollment | 50 |
Est. completion date | August 1, 2018 |
Est. primary completion date | May 1, 2018 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility |
Inclusion Criteria: - mechanically ventilated patients who had received liver transplants and were expected to stay in the ICU more than 2 days were studied. Exclusion Criteria: - Refusal - patients who were extubated before 36 hrs |
Country | Name | City | State |
---|---|---|---|
Korea, Republic of | Hakjae Lee | Seoul |
Lead Sponsor | Collaborator |
---|---|
Asan Medical Center |
Korea, Republic of,
Kross EK, Sena M, Schmidt K, Stapleton RD. A comparison of predictive equations of energy expenditure and measured energy expenditure in critically ill patients. J Crit Care. 2012 Jun;27(3):321.e5-12. doi: 10.1016/j.jcrc.2011.07.084. Epub 2012 Mar 14. — View Citation
McClave SA, Martindale RG, Kiraly L. The use of indirect calorimetry in the intensive care unit. Curr Opin Clin Nutr Metab Care. 2013 Mar;16(2):202-8. doi: 10.1097/MCO.0b013e32835dbc54. Review. — View Citation
Sundström M, Tjäder I, Rooyackers O, Wernerman J. Indirect calorimetry in mechanically ventilated patients. A systematic comparison of three instruments. Clin Nutr. 2013 Feb;32(1):118-21. doi: 10.1016/j.clnu.2012.06.004. Epub 2012 Jul 3. — View Citation
Xiao GZ, Su L, Duan PK, Wang QX, Huang Y. [Comparison of measuring energy expenditure with indirect calorimetry and traditional estimation of energy expenditure in patients in intensive care unit]. Zhongguo Wei Zhong Bing Ji Jiu Yi Xue. 2011 Jul;23(7):392 — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Comparing REE with the measurement for each predictive equation and indirect calorimetry | The REEs derived from each predictive equation were compared with the measured REE using an intraclass correlation coefficient (ICC) and a Bland-Altman plot. | 1 year |
Status | Clinical Trial | Phase | |
---|---|---|---|
Withdrawn |
NCT04132700 -
Longitudinal Evaluation of Energy Expenditure in ICU Patients From Admission to Discharge Using A Novel Indirect Calorimeter: LEEP-Forward Trial
|
N/A | |
Recruiting |
NCT05008757 -
Comparison of Indirect Calorimetry by Q-NRG With Deltatrac II
|
||
Recruiting |
NCT04500483 -
Indirect Calorimetry in Patients at Risk of Malnutrition
|