Clinical Trials Logo

Clinical Trial Summary

The aim is to study bone and soft tissue response to zirconia immediate implants.Volumetric changes will be measured before tooth extraction and after final crow placement.


Clinical Trial Description

Bone remodeling around immediate implants is a reality in clinical and literature arena. much is known about titanium implants but little in zirconia implants

In patients that require a tooth extraction anywhere in the oral cavity except 3rd molars are candidates fo the study. Once clinical conditions are establish and medical clearance is ok, the decision for an immediate implant is taken.

Patient will undergo for an intraoral Scanner (IOS, Trios 3Shape) to get an STL file of the previous situation.

On the day of surgery an atraumatically tooth extraction is performed (without rasing a flap) and a Zirconia implant is inserted on the alveolar socket.

The jumping gap (distance from crystal bone to implant body will be filled with a zenograft type of biomaterial) no sutures or membrane will be used.

A provisional crown or an individualized healing abutment will be placed. After 3 month healing an IOS will be made for crown fabrication and a second STL file generated.

After 15 days final crown will be placed, and 3 month after a 3rd IOS made to get the 3rd and final STL file.

An STL software will then make the correlation between the volume behavior in those 3 stages.

The control group, patients go for tooth extraction but no immediate implant and undergo with a classic protocol for implant placement. In this case the STL files are taken pre-operatory, before implant placement 3 month after tooth extraction, 2 month after implant placement (at final impression level), and 3 month after crown placement. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04027660
Study type Observational [Patient Registry]
Source Instituto de Implantologia
Contact
Status Active, not recruiting
Phase
Start date January 26, 2019
Completion date August 26, 2020

See also
  Status Clinical Trial Phase
Completed NCT03784430 - Soft and Hard Tissue Changes After Immediate Single-tooth Replacement N/A
Completed NCT02096978 - Comparing Implant Stability Using Two Accepted Techniques for Implant Sites N/A
Completed NCT04048239 - Development of a Robotic Minimally Invasive Pathway for Cochlear Implantation N/A
Recruiting NCT06150768 - Porcelain-fused-to-metal Versus Zirconia Implant- Supported in Mandibular Kennedy Class II N/A
Completed NCT02175550 - A 5-year Clinical Evaluation Study on NobelReplace Conical Connection Implants N/A
Completed NCT01066780 - ClearVoice Sound-processing Strategy for AB HiRes 120 Cochlear Implant Users N/A
Completed NCT05190614 - Radiographic Evaluation of a Star-shaped Incision Technique
Completed NCT04706078 - Clinical and Radiographic Evaluation of a Cross-shaped Incision Technique
Recruiting NCT04935944 - Effect of FOV and mA on Metal Artifacts on CBCT
Not yet recruiting NCT05387421 - Evaluating the PrimeTaper EV Implant for 5 Years N/A
Terminated NCT02373787 - A 5 Year Clinical Investigation on Creos Xenoprotect N/A
Completed NCT05869292 - Immediate Vs. Early Loading of Immediately Placed Implants N/A
Completed NCT02861313 - Oral Health Related Quality of Life and Peri-implant Condition in Single Implant Overdenture N/A
Not yet recruiting NCT05723926 - Carotid Implants for PreveNtion of STrokE ReCurrEnce From Large Vessel Occlusion in Atrial Fibrillation Patients Treated With Oral Anticoagulation N/A
Completed NCT03100448 - A 1-year Clinical Investigation on the On1 Concept N/A
Terminated NCT01279187 - The Impact of Parathyroid Hormone (PTH) on Craniofacial Osseous Regeneration in Bone Phase 2
Completed NCT02362854 - Efficacy of Diode Laser in Peri-implantitis N/A
Terminated NCT04676061 - Effects of a Progestin on Frequent and/or Prolonged Bleeding With Nexplanon™ Phase 4
Recruiting NCT04942327 - Awareness Among Hearing Enhancement Interventions and Reimbursement Criteria of Hearing Implants N/A
Recruiting NCT05768295 - Multicentric Observational Study Confirming the Performance and Safety of the Axiom® BL X3 Implants N/A