Implant Stability Clinical Trial
Official title:
Effect of Undersized Drilling Upon the Primary and Secondary Stability of Immediate Conical Implants in the Esthetic Maxillary Sector
Verified date | April 2020 |
Source | University of Carabobo |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
OBJECTIVE:
evaluate the effect of undersized drilling upon the primary and secondary stability of
immediate implants placed in the anterior sector maxilla.
PATIENTS AND METHODS Study design A randomized comparative clinical trial was carried out.
Thirty conical MIS C1 grade 23 titanium alloy (Ti 6Al 4V Eli) implants with a rough surface
subjected to dual acid etching and sandblasting, measuring 3.75 mm in maximum diameter and 13
mm in length (MIS® Implants Technologies, Ltd. Bar Levi, Israel), were placed immediately
after removal a anterior maxillary tooth in a series of patients treated in the clinic of the
Master of Dentistry and Dental Implantology (Santa María University, Dental School, Caracas,
Venezuela). The study was approved by the local Ethics Committee.
Patient selection To enrolled in the study, patients had to comply the inclusion/exclusion
criteria established to the study: over 18 years of age with indication of one or more
immediate implants in the anterior maxilla; no history of ischemic heart disease,
uncontrolled diabetes, coagulation disorders, head or neck radiotherapy, intravenous
bisphosphonates or uncontrolled periodontal disease. Based on a CTCB evaluation, the teeth
involved should have presence of bone ≥ 5 mm from the tooth apex to the lower cortical layer
of the nasal fossa / maxillary sinus and no vertical defects greater than 4 mm at the buccal
or palatine alveolar crest. Also, patients must have capacity to understand the study
protocol and fill consent form to participation in the study.
Study procedure Two operators calibrated for immediate implant placement performed minimally
traumatic tooth extraction following local infiltrating anesthesia with 4% articaine and
1:100,000 epinephrine (Artheek® 4%, New Stetic S.A.; Antioquia, Colombia). After evaluating
the integrity of the bone walls, drilling sequence was established on a randomized basis.
Conventional drilling (CD) sequence:
- Marking drill ∅1.9 mm at 1500 rpm
- Pilot drill ∅ 2.4 mm and 13 mm in length at 800 rpm.
- Twist drill ∅3 mm at 400 rpm.
Undersized drilling (UD) sequence:
Marking drill ∅1.9 mm at 1500 rpm Pilot drill ∅ 2.4 mm and 13 mm in length at 400 rpm.
Implant insertion A surgical motor (MCU MIS, model M0132, W&H, Burmoos, Austria) with a 20:1
reducing implant handpiece was used to insert the implants at 20 rpm and applying a torque of
10 Ncm. Following placement of the implant in the bed, manual insertion was continued to
reach the final implant position, established as 4 mm from the gingival margin.
Study variables Two torque meters (MIS® Implants LTD, models MT-RI040 and MT-RT070, Bar Levi,
Israel) were used to insert and sequentially measure the maximum IT reached on positioning
the implant in the socket. A Smart-peg Nro 49 model 100480 was fitted to the connection of
each implant and an Osstell ISQ® (SN 4669 Osstell AB, Goteborg, Sweden) was used to perform
RFA analysis and obtain corresponding ISQ value at insertion time (RFA1). A 4 mm height
healing screw was used to seal the implant, and then additional RFA measurements was made at
6 week (RFA2) and 12 week (RFA3) post-implantation
Status | Completed |
Enrollment | 30 |
Est. completion date | March 17, 2018 |
Est. primary completion date | December 17, 2017 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 18 Years and older |
Eligibility |
Inclusion Criteria: indication of one or more immediate implants in the anterior maxilla; No history of ischemic heart disease, No History of uncontrolled diabetes, No coagulation disorders, No head or neck radiotherapy Exclusion Criteria: Periodontal Disease. History of EV or Oral Bisphosphonate |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
University of Carabobo |
Sierra-Rebolledo A, Allais-Leon M, Maurette-O'Brien P, Gay-Escoda C. Primary Apical Stability of Tapered Implants Through Reduction of Final Drilling Dimensions in Different Bone Density Models: A Biomechanical Study. Implant Dent. 2016 Dec;25(6):775-782. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Insertion Torque | Maximum torque in N.cm obtained during insertion of the implant | at baseline, through study completion in average 1 year | |
Primary | RFA Implant Stability | Implant Stability measure by Radio-Frequency Analysis. | at baseline, through study completion in average 1 year | |
Secondary | RFA2 Implant Stability | Implant Stability measure by Radio-Frequency Analysis 6 weeks later | 6 weeks after baseline, trough study completion in average 1 year | |
Secondary | RFA3 Implant Stability | Implant Stability measure by Radio-Frequency Analysis 12 weeks later | 12 weeks after baseline, trough study completion in average 1 year |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04189718 -
Comparative Evaluation of Osseodensification Versus Conventional Implant Site
|
N/A | |
Not yet recruiting |
NCT03689933 -
Stability of Patient-specific Root-analogue Implants and Conventional Root-form Implants for Treating Non-restorable Single-rooted Maxillary Teeth
|
N/A | |
Recruiting |
NCT04442763 -
The Effect of Osseodensification on Implant Stability in Posterior Maxilla
|
N/A | |
Completed |
NCT05141851 -
The Impact of Thread Length on Implant Stability
|
N/A | |
Recruiting |
NCT04718246 -
Stability Of Dental Implants Placed In Healed Bony Sites Of Hyperlipidemic Patients: A Case Series
|
N/A | |
Completed |
NCT04761445 -
Comparison Between Two Different Tissue-Level Implant Systems: A Prospective Clinical Study
|
N/A |