Implant Site Reaction Clinical Trial
Official title:
Clinical and Radiographic Outcomes of a New Fully Tapered Implant With the One-time One-abutment Approach: In-line Clinical Case Series With 1-year Follow-up
Objective: The aim of this prospective observational clinical study is to evaluate the bone level changes in a new implant design, fully tapered and platform switching with the one-time one-abutment protocol after one year of loading. Material and methods: Thirty patients received 1 or 2 implants (6, 8 and 10 mm in length, 3.5, 3.75 or 4.5 mm diameter and bone level design) to replace a single or multiple gap. Radiographic, clinical, esthetic and survival success rate were evaluated after one year of loading. Results: At 12 months post final loading, there were no peri-implant bone loss in any of the cases. Mean marginal crestal bone loss between surgery and crown placement was 0.19 ± 0.17 (p <0.0001). Between surgery and 12 months of follow-up, the mean marginal crestal bone loss was 0.25 ± 0.24 (p <0.0001). There were a SSD between 1 year follow-up and crown placement in PI in the mesial (0.33 ± 0.54 p= 0.003) and distal aspect (0.5 ± 0.73 p= 0.001). The PPD was SSD deeper at 1 year follow-up than at crown placement only in the mesial and distal probing (averaged depth=0.75 and p<0.0005). No statistically significant differences were found for any of the other clinical and est
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT04092920 -
Implant Stability of Laser vs SLA Surface Treated Implants Placed in Fresh Extraction Sockets
|
N/A | |
Not yet recruiting |
NCT05973357 -
The Influence of Vertical Implant Position With Immediate Provisionalization on the Marginal Bone Loss.
|
N/A | |
Enrolling by invitation |
NCT05675241 -
Characterizing the Inflammation Around Dental Implants
|
||
Not yet recruiting |
NCT03598049 -
Assessment of Dental Implants Placed in Posterior Maxillary Ridge Using Densah Burs Versus Standard Drills
|
N/A | |
Completed |
NCT05730400 -
Histological Assessment of BMAC Utilized in Sinus Lift
|
N/A | |
Completed |
NCT05999760 -
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
|
N/A | |
Active, not recruiting |
NCT06020040 -
Bone Particles Sizes and the Stability of Soft and Hard Tissue in Aesthetic Area
|
N/A | |
Completed |
NCT06468592 -
Implantation in Posterior Maxilla in Cases With Insufficient Bone
|
N/A | |
Recruiting |
NCT06022042 -
Clinical Comparison of On1 Two-stage Abutment With One-stage Abutment on Different Implant Neck Design
|
N/A | |
Completed |
NCT06146244 -
Comparison of ISQ in Implants Placed in Antral Area on Native Bone vs Regenerated Bone
|
||
Completed |
NCT05936775 -
Assessment of Osseointegration Properties of Nano-Hydroxy Apatite Coated Titanium Implant
|
N/A | |
Recruiting |
NCT06164353 -
the Peri-implant Tissue Changes Around Implants in the Esthetic Zone Using Demineralized Dentin Graft vs Xenograft
|
N/A | |
Not yet recruiting |
NCT06446687 -
Radiographic Assessment of Bone Gain Following Sinus Lifting With Simultaneous Implant Placement Using Crestal Approach With Membrane Control Technique for Bone Augmentation of Atrophied Maxillary Posterior Ridge
|
N/A | |
Recruiting |
NCT06043037 -
Elamrousy Modified Approach for Socket Shield Technique
|
N/A | |
Recruiting |
NCT05817526 -
BMAC Loaded Collagen Jumping the Gap Around Immediate Implants
|
N/A | |
Completed |
NCT04230837 -
Marginal Bone Level Around Implants With Definitive Abutments
|
N/A | |
Completed |
NCT03305679 -
Clinical Efficacy of the Immediate Implant Loading
|
N/A | |
Completed |
NCT04332185 -
Vestibular Socket Therapy in Compromised Sockets
|
N/A | |
Recruiting |
NCT05057143 -
3D Printed Implants for the Defect Reconstruction in Patients With Chest Wall Tumors
|
N/A | |
Recruiting |
NCT06226038 -
Effect of Static Magnetic Field on Dental Implant Stability.
|
N/A |