Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT06142019
Other study ID # 21-35637
Secondary ID
Status Recruiting
Phase
First received
Last updated
Start date March 1, 2024
Est. completion date August 1, 2025

Study information

Verified date February 2024
Source University of California, San Francisco
Contact Phil Bickler, MD, PhD
Phone 415-476-1411
Email Philip.bickler@ucsf.edu
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

The aim of this project is to test the accuracy of pulse oximeters during mild, moderate and severe hypoxia. This is done by comparing the reading of the pulse oximeter during brief, steady state hypoxia with a gold-standard measurement of blood oxygen. This study will be done on healthy male or females between the age group of 18-50.


Description:

This study is to determine the accuracy of pulse oximeters, which measure blood oxygen by shining light through fingers, ears or other parts of the body, without requiring blood sampling. The aim of this project is to test the accuracy of pulse oximeters during mild, moderate and severe hypoxia. This is done by comparing the reading of the pulse oximeter during brief, steady state hypoxia with a gold-standard measurement of blood oxyhemoglobin saturation (arterial blood sample processed in a laboratory hemoximeter).The data obtained is submitted by pulse oximeter manufacturers to the FDA for device approval. Studies normally involve 10-14 normal adult volunteer paid subjects, with 20-25 1-2 ml arterial blood samples from each subject obtained at different steady-state levels of hypoxia from 70-100%. Blood samples obtained from an arterial line are measured in a hemoximeter to determine true saturation value. Some sponsors may not require any blood sampling. Some sponsors may require additional blood samples, up to 35 samples may be drawn. Readings from the test pulse oximeters are recorded and compared to these "gold-standard" blood values. The pulse oximeter probes may be located at a variety of sites on the subjects, including fingers, toes, ears, forehead, scalp and bridge of the nose. These detector-probes are all non-invasive. The level of hypoxia is measured and controlled by the investigator. A computer program that displays a prediction, breath by breath, the arterial oxygen saturation, (SaO2) of the study subject. SaO2 is computed from end-expired Po2 and Pco2 as determined by mass spectrometer gas analysis. This information permits the inspired gas mixture of air, plus CO2 and nitrogen, to be adjusted by an operator watching the value computed after each expiration on an analog meter. This computer-estimated saturation is adjusted by the operator to one of 6 levels of predicted saturation, and is held stable for about 30 seconds at each level. Two or three "runs" are conducted per subject. Each "run" lasts 10-15 min and 4 to 5 plateaus are tested per run. The manufacturer may choose the target values. Plateaus are typically sought at 96%, 87%, 77%, 92%, 82% and 72%. Other manufacturers have asked for an equal number of data points but with all points between 70% and 100%. Some sponsors may also request additional variables to be measured during testing including high or low CO2, where subjects will be asked to hyperventilate; low perfusion, where subjects will be asked to lay flat, or with their head up or down; testing pulse oximeters during motion, or with the subject's hand fixed to a motion machine. The subject's will be informed by the study staff and in the consent form if any of these additional procedures apply.


Recruitment information / eligibility

Status Recruiting
Enrollment 10000
Est. completion date August 1, 2025
Est. primary completion date August 1, 2025
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 21 Years to 50 Years
Eligibility Inclusion Criteria: 1. The subject is male or female, aged =21 and <50. 2. The subject is in good general health with no evidence of any medical problems. 3. The subject is fluent in both written and spoken English. 4. The subject has provided informed consent and is willing to comply with the study procedures. Exclusion Criteria: 1. The subject is obese (BMI>30). 2. The subject has a known history of heart disease, lung disease, kidney or liver disease. 3. Diagnosis of asthma, sleep apnea, or use of CPAP. 4. Subject has diabetes. 5. Subject has a clotting disorder. 6. The subject a hemoglobinopathy or history of anemia, per subject report or the first blood sample, that in the opinion of the investigator, would make them unsuitable for study participation. 7. The subject has any other serious systemic illness. 8. The subject is a current smoker. 9. Any injury, deformity, or abnormality at the sensor sites that in the opinion of the investigators' would interfere with the sensors working correctly. 10. The subject has a history of fainting or vasovagal response. 11. The subject has a history of sensitivity to local anesthesia. 12. The subject has a diagnosis of Raynaud's disease. 13. The subject has unacceptable collateral circulation based on exam by the investigator (Allen's test). 14. The subject is pregnant, lactating or trying to get pregnant. 15. The subject is unable or unwilling to provide informed consent, or is unable or unwilling to comply with study procedures. 16. The subject has any other condition, which in the opinion of the investigators' would make them unsuitable for the study.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Controlled desaturation (hypoxemia)
Stable hypoxemia is created in healthy subjects by having them breathe hypoxic air mixtures

Locations

Country Name City State
United States Hypoxia Lab, UCSF Department of Anesthesia and Perioperative Care San Francisco California

Sponsors (1)

Lead Sponsor Collaborator
University of California, San Francisco

Country where clinical trial is conducted

United States, 

References & Publications (3)

Bickler PE, Feiner JR, Severinghaus JW. Effects of skin pigmentation on pulse oximeter accuracy at low saturation. Anesthesiology. 2005 Apr;102(4):715-9. doi: 10.1097/00000542-200504000-00004. — View Citation

Feiner JR, Bickler PE, Mannheimer PD. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia. Anesth Analg. 2010 Jul;111(1):143-8. doi: 10.1213/ANE.0b013e3181c91bb6. Epub 2009 Dec 10. — View Citation

Feiner JR, Severinghaus JW, Bickler PE. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender. Anesth Analg. 2007 Dec;105(6 Suppl):S18-S23. doi: 10.1213/01.ane.0000285988.35174.d9. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary SpO2 Reading on pulse oximeter device which is an estimate of the patient's blood oxygen level. 08/01/2025
Secondary Blood gas SO2 Arterial blood gas sample results showing exact SpO2 levels. SpO2 ranges from 1% to 100%. Our target SpO2 levels are between 67% and 100%. 08/01/2025
Secondary Skin Pigmentation by ITA ITA stands for individual typology angle from a spectrophotometer which is an objective measurement of skin pigmentation. The categories for the ITA scale are the following: > 55 Very Light, 41 to 55 Light, 28 to 41 Intermediate, 10 to 28 Tan, -30 to 10 Brown, < -30 Dark. 08/01/2025
Secondary Finger Diameter Finger diameter is measured to ensure that the pulse oximeters being tested work with a variety of finger sizes. Finger diameter is measured in mm. 08/01/2025
Secondary Skin Pigmentation by Monk Scale The Monk scale is a subjective categorization of skin pigmentation. The Monk Scale is a 10 shade scale designed to to be easy-to-use for development and evaluation of technology while presenting a more representative range of skin tones than other common qualitative scales. The Monk Scale is from A to J. A being the lightest skin color and J the darkest. 08/01/2025
See also
  Status Clinical Trial Phase
Recruiting NCT04498598 - Structural Modification In Supraglottic Airway Device N/A
Completed NCT05532670 - N600X Low Saturation Accuracy Validation
Enrolling by invitation NCT04106401 - Intravascular Volumes in Hypoxia During Antarctic Confinement N/A
Recruiting NCT05883137 - High-flow Nasal Oxygenation for Apnoeic Oxygenation During Intubation of the Critically Ill
Not yet recruiting NCT05817448 - Hypoxia-induced Autophagy in the Pathogenesis of MAP
Recruiting NCT02661152 - DAHANCA 30: A Randomized Non-inferiority Trial of Hypoxia-profile Guided Hypoxic Modification of Radiotherapy of HNSCC. Phase 3
Terminated NCT02801162 - Evaluation of Accuracy and Precision of a New Arterial Blood Gas Analysis System Blood in Comparison With the Reference Standard N/A
Not yet recruiting NCT02201875 - Intrinsic Periodic Pattern of Breathing N/A
Completed NCT02943863 - Regional Ventilation During High Flow Nasal Cannula and Conventional Nasal Cannula in Patients With Hypoxia N/A
Completed NCT01922401 - Inverse Ratio Ventilation on Bariatric Operation N/A
Completed NCT02105298 - Effect of Volume and Type of Fluid on Postoperative Incidence of Respiratory Complications and Outcome (CRC-Study) N/A
Active, not recruiting NCT01681238 - Goal-directed Therapy in High-risk Surgery N/A
Completed NCT01463527 - Using Capnography to Reduce Hypoxia During Pediatric Sedation N/A
Completed NCT01507623 - Value of Capnography During Nurse Administered Propofol Sedation (NAPS) N/A
Withdrawn NCT00638040 - The Gene Expression Studies of the Role of Tumor Microenvironments in Tumor Progression N/A
Active, not recruiting NCT06097754 - Intermittent Exogenous Ketosis (IEK) at High Altitude N/A
Completed NCT04589923 - The VISION-Acute Study
Completed NCT05044585 - Evaluation of RDS MultiSense® in Desaturation Analysis in Healthy Volunteers N/A
Completed NCT03659513 - The Effect of ECMO on the Pharmacokinetics of the Drugs and Their Clinical Efficacy
Completed NCT03221387 - Sleep and Daytime Use of Humidified Nasal High-flow Oxygen in COPD Outpatients N/A