Hypoxia Clinical Trial
Official title:
Determination of SpO2 and PR Accuracy Specifications at Rest / Accuracy of Pulse Oximeters With Profound Hypoxia NIHO 18/ Pulse Oximeter Accuracy Evaluation Protocol
The aim of this study is to determine the accuracy of devices called pulse oximeters, which measure blood oxygen by shining light through fingers, ears or other skin, without requiring blood sampling. Study will be used with patients at rest.
Status | Recruiting |
Enrollment | 13 |
Est. completion date | April 8, 2025 |
Est. primary completion date | April 9, 2024 |
Accepts healthy volunteers | |
Gender | All |
Age group | 18 Years to 50 Years |
Eligibility | Inclusion Criteria: - Both male and female subjects who can give written informed consent - Healthy subjects capable of undergoing controlled hypoxemia to the levels outlined in the desaturation profile - Meeting the demographic requirements Exclusion Criteria: - Age below 18 or over 50 - Pregnant women - Significant arrhythmia - Blood pressure above 150 systolic or 90 diastolic - Carboxyhemoglobin levels over 3% - Subjects whom the investigator consider ineligible for the study |
Country | Name | City | State |
---|---|---|---|
United States | UCSF Hypoxia Research Laboratory | San Francisco | California |
Lead Sponsor | Collaborator |
---|---|
Nihon Kohden | University of California, San Francisco |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Accuracy of Sensor Oxygen Saturation by Arms Calculation | Accuracy will be determined by comparing the noninvasive blood oxygen saturation measurement of the pulse oximeter (SpO2i) to that obtained from a blood sample (SRi) and calculating the arithmetic root mean square (Arms) error value as follows:
Arms =Square root (sum of n samples of ((SpO2i - SRi) squared) / n) |
30 seconds | |
Secondary | Accuracy of Sensor Pulse Rate by Arms Calculation | Accuracy will be determined by comparing the noninvasive pulse rate measurement of the pulse oximeter (PRi) to the heart rate obtained from an electrocardiography reference device (HRRi) and calculating the arithmetic root mean square (Arms) error value as follows:
Arms =Square root (sum of n samples of ((PRi - HRRi) squared) / n) |
30 seconds |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04498598 -
Structural Modification In Supraglottic Airway Device
|
N/A | |
Completed |
NCT05532670 -
N600X Low Saturation Accuracy Validation
|
||
Enrolling by invitation |
NCT04106401 -
Intravascular Volumes in Hypoxia During Antarctic Confinement
|
N/A | |
Recruiting |
NCT05883137 -
High-flow Nasal Oxygenation for Apnoeic Oxygenation During Intubation of the Critically Ill
|
||
Not yet recruiting |
NCT05817448 -
Hypoxia-induced Autophagy in the Pathogenesis of MAP
|
||
Recruiting |
NCT02661152 -
DAHANCA 30: A Randomized Non-inferiority Trial of Hypoxia-profile Guided Hypoxic Modification of Radiotherapy of HNSCC.
|
Phase 3 | |
Terminated |
NCT02801162 -
Evaluation of Accuracy and Precision of a New Arterial Blood Gas Analysis System Blood in Comparison With the Reference Standard
|
N/A | |
Completed |
NCT02943863 -
Regional Ventilation During High Flow Nasal Cannula and Conventional Nasal Cannula in Patients With Hypoxia
|
N/A | |
Not yet recruiting |
NCT02201875 -
Intrinsic Periodic Pattern of Breathing
|
N/A | |
Completed |
NCT02105298 -
Effect of Volume and Type of Fluid on Postoperative Incidence of Respiratory Complications and Outcome (CRC-Study)
|
N/A | |
Completed |
NCT01922401 -
Inverse Ratio Ventilation on Bariatric Operation
|
N/A | |
Active, not recruiting |
NCT01681238 -
Goal-directed Therapy in High-risk Surgery
|
N/A | |
Completed |
NCT01463527 -
Using Capnography to Reduce Hypoxia During Pediatric Sedation
|
N/A | |
Completed |
NCT01507623 -
Value of Capnography During Nurse Administered Propofol Sedation (NAPS)
|
N/A | |
Withdrawn |
NCT00638040 -
The Gene Expression Studies of the Role of Tumor Microenvironments in Tumor Progression
|
N/A | |
Active, not recruiting |
NCT06097754 -
Intermittent Exogenous Ketosis (IEK) at High Altitude
|
N/A | |
Completed |
NCT04589923 -
The VISION-Acute Study
|
||
Completed |
NCT05044585 -
Evaluation of RDS MultiSense® in Desaturation Analysis in Healthy Volunteers
|
N/A | |
Completed |
NCT03659513 -
The Effect of ECMO on the Pharmacokinetics of the Drugs and Their Clinical Efficacy
|
||
Completed |
NCT03221387 -
Sleep and Daytime Use of Humidified Nasal High-flow Oxygen in COPD Outpatients
|
N/A |