Hypoxia Clinical Trial
Official title:
RDS MultiSense® SpO2 Calibration
Verified date | March 2023 |
Source | Rhythm Diagnostic Systems |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Data will be collected with the MultiSense® pulse oximetry system during non-motion conditions over the range of 70-100%. A Clinimark reference system, previously correlated to arterial blood CO-Oximetry will be the basis for comparison. A minimum of fifteen (15) up to fifty (50) healthy adult subjects, ranging in pigmentation from light to dark, with at least six (6) subjects with dark pigmentation (Fitzpatrick 5-6), will be enrolled in the study to meet the study design requirements defined by ISO 80601-2-61 and by the FDA's Guidance for Pulse Oximeters (March 4, 2013). SpO2 data will be evaluated during non-motion conditions. SpO2 data will be evaluated during stable step plateaus of induced hypoxic levels. The investigational device will be placed on the thorax of the subjects (patch on the upper back and external electrode on the right pectoral). Simultaneous data collection will be set up for the reference and the systems under test.
Status | Active, not recruiting |
Enrollment | 16 |
Est. completion date | April 17, 2024 |
Est. primary completion date | March 17, 2022 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 18 Years to 50 Years |
Eligibility | Inclusion Criteria: - Subject must have the ability to understand and provide written informed consent - Subject is 18 to 50 years of age - Subject must be willing and able to comply with study procedures and duration - Subject is a non-smoker or who has not smoked within 2 days prior to the study. - Male or female of any race - Subject demographics include a range of skin pigmentations, including at least 3 darkly pigmented subjects or 15% of the subject pool, whichever is larger. Exclusion Criteria: - Subject is considered as being morbidly obese (defined as BMI >39.5) - Compromised circulation, injury, or physical malformation of fingers, toes, hands, ears or forehead/skull or other sensor sites, tattoo in the optical path which would limit the ability to test sites needed for the study. (Note: Certain malformations may still allow subjects to participate if the condition is noted and would not affect the particular sites utilized.) - Females who are pregnant, who are trying to get pregnant, (confirmed by positive urine pregnancy test unless the subject is known to be not of child-bearing potential) - Subjects who have smoked in the last 2 days with COHb levels >3% as assessed with a Masimo Radical 7 (Rainbow) - Subjects with known respiratory conditions (self-reported) - Subjects with known heart or cardiovascular conditions (self-reported, except for blood pressure and ECG review) or with an implantable active medical device such as pacemaker or automatic defibrillator - Self-reported health conditions as identified in the Health Assessment Form (self-reported) - Subjects with severe contact allergies to standard adhesives, latex or other materials found in pulse oximetry sensors, ECG electrodes, respiration monitor electrodes or other medical sensors (self-reported) - Unwillingness or inability to remove colored nail polish from test digits. - Unwillingness to have chest or other test site shaved - Other known health condition, should be considered upon disclosure in health assessment form |
Country | Name | City | State |
---|---|---|---|
United States | Clinimark LLC | Louisville | Colorado |
Lead Sponsor | Collaborator |
---|---|
Rhythm Diagnostic Systems | Clinimark, LLC |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Determination of the quality of measurements of arterial blood saturation (SpO2) provided by the MultiSense® system in comparison to measurements made with a reference Pulse Oximetry System, in terms of accuracy. | Accuracy is defined as an average measurement variation less than 3.5% of the mean value to the reference standard. Reference Pulse Oximetry Systems, previously compared to Reference CO-Oximetry will be used as the basis for comparison. The study population will include 15 to 50 subjects. The data for analysis will be equally distributed across the range of 70-100%. All data will be used for the analysis unless identified as unstable by the control oximeter. Data that is found to be unstable will be removed prior to the comparative analysis. | from device placement to device removal, assessed up to 3 hours |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04498598 -
Structural Modification In Supraglottic Airway Device
|
N/A | |
Completed |
NCT05532670 -
N600X Low Saturation Accuracy Validation
|
||
Enrolling by invitation |
NCT04106401 -
Intravascular Volumes in Hypoxia During Antarctic Confinement
|
N/A | |
Recruiting |
NCT05883137 -
High-flow Nasal Oxygenation for Apnoeic Oxygenation During Intubation of the Critically Ill
|
||
Not yet recruiting |
NCT05817448 -
Hypoxia-induced Autophagy in the Pathogenesis of MAP
|
||
Recruiting |
NCT02661152 -
DAHANCA 30: A Randomized Non-inferiority Trial of Hypoxia-profile Guided Hypoxic Modification of Radiotherapy of HNSCC.
|
Phase 3 | |
Terminated |
NCT02801162 -
Evaluation of Accuracy and Precision of a New Arterial Blood Gas Analysis System Blood in Comparison With the Reference Standard
|
N/A | |
Not yet recruiting |
NCT02201875 -
Intrinsic Periodic Pattern of Breathing
|
N/A | |
Completed |
NCT02943863 -
Regional Ventilation During High Flow Nasal Cannula and Conventional Nasal Cannula in Patients With Hypoxia
|
N/A | |
Completed |
NCT01922401 -
Inverse Ratio Ventilation on Bariatric Operation
|
N/A | |
Completed |
NCT02105298 -
Effect of Volume and Type of Fluid on Postoperative Incidence of Respiratory Complications and Outcome (CRC-Study)
|
N/A | |
Active, not recruiting |
NCT01681238 -
Goal-directed Therapy in High-risk Surgery
|
N/A | |
Completed |
NCT01463527 -
Using Capnography to Reduce Hypoxia During Pediatric Sedation
|
N/A | |
Completed |
NCT01507623 -
Value of Capnography During Nurse Administered Propofol Sedation (NAPS)
|
N/A | |
Withdrawn |
NCT00638040 -
The Gene Expression Studies of the Role of Tumor Microenvironments in Tumor Progression
|
N/A | |
Active, not recruiting |
NCT06097754 -
Intermittent Exogenous Ketosis (IEK) at High Altitude
|
N/A | |
Completed |
NCT04589923 -
The VISION-Acute Study
|
||
Completed |
NCT05044585 -
Evaluation of RDS MultiSense® in Desaturation Analysis in Healthy Volunteers
|
N/A | |
Completed |
NCT03659513 -
The Effect of ECMO on the Pharmacokinetics of the Drugs and Their Clinical Efficacy
|
||
Completed |
NCT03221387 -
Sleep and Daytime Use of Humidified Nasal High-flow Oxygen in COPD Outpatients
|
N/A |