The purpose of this study is to test the accuracy of a web cam-based biomedical device developed at UVA (not FDA-approved) that is designed to measure heart rate, respiratory rate, and oxygen saturation without requiring any patient contact. One potential application of such a device would be in the field of infant monitoring allowing parents (and physicians) to monitor the vital signs of infants continuously. The investigators therefore propose to record the heart rate, respiratory rate, and oxygen saturation of 100 infants (defined as children aged 12 months or less) who are receiving continuous oxygen, heart rate, and respiratory rate monitoring with a traditional vital signs monitor. The relationship between "non-contact" and "gold standard" (GE monitoring equipment) heart rate, respiratory rate, and oxygen saturation will be analyzed using regression and limits of agreement analysis.


Clinical Trial Description

While multiple investigators have attempted to develop non-contact pulse oximeters, none of these devices have achieved accuracy sufficient for clinical use, no such devices have been approved by the Food and Drug Administration, and there are currently no such devices on the market in the United States. While these devices are typically able to measure the heart and respiratory rates with some accuracy,v the accurate calculation of oxygen saturation from the arterial pulse (SpO2) using a "non-contact" reflectance oximetry probe is complicated by the interference of ambient light, patient temperature changes, as well as the inherent limitations of the sensing devices currently utilized. Poh et al have been somewhat successful at calculating the heart rate from a video recording using independent component analysis. However, Poh's method does not calculate instantaneous rates and requires a facial recognition component to track the facial orientation in the image, is not capable of measuring respiratory rate, and relies primarily on analysis of reflected green light (which cannot be used for the calculation of oxygen saturation). Our work involves modifying a commercial off the shelf (COTS) 3-channel (red, green, blue) CCD (charge coupled device) or CMOS (complementary metal oxide semiconductor) camera in the form of a web cam to detect near infrared and infrared spectrum radiation and applying an algorithm based fast Fourier transformation (FFT) of individual red pixel intensity to detect motion and color changes. Because our algorithm analyzes the first derivative of red pixel intensity, a face-tracking component is unnecessary, and we are able to calculate the heart rate and the respiratory rate in real time. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02287220
Study type Observational
Source University of Virginia
Contact Keita Ikeda, PhD
Phone 9195931174
Email keita.ikeda@virginia.edu
Status Recruiting
Phase
Start date November 2014
Completion date November 2019

See also
  Status Clinical Trial Phase
Recruiting NCT04498598 - Structural Modification In Supraglottic Airway Device N/A
Completed NCT05532670 - N600X Low Saturation Accuracy Validation
Enrolling by invitation NCT04106401 - Intravascular Volumes in Hypoxia During Antarctic Confinement N/A
Recruiting NCT05883137 - High-flow Nasal Oxygenation for Apnoeic Oxygenation During Intubation of the Critically Ill
Not yet recruiting NCT05817448 - Hypoxia-induced Autophagy in the Pathogenesis of MAP
Recruiting NCT02661152 - DAHANCA 30: A Randomized Non-inferiority Trial of Hypoxia-profile Guided Hypoxic Modification of Radiotherapy of HNSCC. Phase 3
Terminated NCT02801162 - Evaluation of Accuracy and Precision of a New Arterial Blood Gas Analysis System Blood in Comparison With the Reference Standard N/A
Not yet recruiting NCT02201875 - Intrinsic Periodic Pattern of Breathing N/A
Completed NCT02943863 - Regional Ventilation During High Flow Nasal Cannula and Conventional Nasal Cannula in Patients With Hypoxia N/A
Completed NCT02105298 - Effect of Volume and Type of Fluid on Postoperative Incidence of Respiratory Complications and Outcome (CRC-Study) N/A
Completed NCT01922401 - Inverse Ratio Ventilation on Bariatric Operation N/A
Active, not recruiting NCT01681238 - Goal-directed Therapy in High-risk Surgery N/A
Completed NCT01463527 - Using Capnography to Reduce Hypoxia During Pediatric Sedation N/A
Completed NCT01507623 - Value of Capnography During Nurse Administered Propofol Sedation (NAPS) N/A
Withdrawn NCT00638040 - The Gene Expression Studies of the Role of Tumor Microenvironments in Tumor Progression N/A
Active, not recruiting NCT06097754 - Intermittent Exogenous Ketosis (IEK) at High Altitude N/A
Completed NCT04589923 - The VISION-Acute Study
Completed NCT05044585 - Evaluation of RDS MultiSense® in Desaturation Analysis in Healthy Volunteers N/A
Completed NCT03659513 - The Effect of ECMO on the Pharmacokinetics of the Drugs and Their Clinical Efficacy
Completed NCT03221387 - Sleep and Daytime Use of Humidified Nasal High-flow Oxygen in COPD Outpatients N/A