Clinical Trials Logo

Clinical Trial Summary

Collect hemodynamic data, such as heart rate, blood pressure, and cardiac output to help understand the effect of pre and post intubation.


Clinical Trial Description

A Non-invasive physiologic monitor, Non-Invasive Cardiac Output Monitor (NICOM), will be utilized for this study. This is the first completely non-invasive hemodynamic device approved by the FDA and available for clinical use produced by Cheetah Medical and utilizes Bioreactance (Tel Aviv, Israel). It performs accurately and with precision in all patient's studied and requires only 4 adhesive gel pads on the skin to measure continuous cardiac output and to calculate Stroke Volume Variation (SVV). Other physiologic data (blood pressure, total peripheral resistance (TPR), stroke volume (SV), and heart rate) will be analyzed in real time and recorded on the device and downloaded into an excel database. The data on the device will be downloaded weekly onto the excel database and deleted on the device. The Study personnel will be trained in its use prior to study initiation. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03525743
Study type Observational
Source Mayo Clinic
Contact
Status Completed
Phase
Start date June 27, 2018
Completion date March 29, 2019

See also
  Status Clinical Trial Phase
Completed NCT04062994 - A Clinical Decision Support Trial to Reduce Intraoperative Hypotension
Active, not recruiting NCT02016599 - Effects of Transitional Circulation in ELBW Infants
Recruiting NCT05836610 - Hydrocortisone Therapy Optimization During Hypothermia Treatment in Asphyxiated Neonates Phase 4
Completed NCT03215797 - Phenylephrine or Norepinephrine for a Better Hemodynamic Stability Phase 3
Suspended NCT02315937 - Hemodynamic Assessment During Spinal Anesthesia Using Transthoracic Echocardiography' N/A
Completed NCT02907931 - Carotid Doppler Ultrasound for the Measurement of Intravascular Volume Status N/A
Recruiting NCT02532270 - Detecting Hypotension By Continuous Non-invasive Arterial Pressure Monitoring N/A
Completed NCT02437799 - Dicrotic Notch and Hypotension at Caesarean Under Spinal Anaesthesia N/A
Completed NCT02802683 - Hemodynamic Impact of Hyperbaric Versus Isobaric for Spinal Anesthesia During Cesarean Delivery Phase 4
Not yet recruiting NCT01941472 - Transcutaneous pO2, Transcutaneous pCO2 and Central Venous pO2 Variations to Predict Fluid Responsiveness N/A
Completed NCT02146898 - The Severity Of Hypotension Comparing Three Positions During Spinal Anesthesia For Cesarean Delivery N/A
Completed NCT01930227 - Transcutaneous Electrical Acupoint Stimulation(TEAS) for Hypotension After Spinal Anesthesia in Parturients N/A
Recruiting NCT01434251 - Treatment of Hypotension of Prematurity (TOHOP) N/A
Completed NCT01592669 - Passive Leg Raising Attenuates and Delays Tourniquet Deflation-induced Hypotension and Tachycardia N/A
Withdrawn NCT01183741 - Accuracy of Non-Invasive Blood Pressure Measurement in Adults Phase 3
Completed NCT00991627 - Different Approaches to Maternal Hypotension During Cesarean Section Phase 4
Withdrawn NCT00750516 - Lactic Acid Levels In Hypotensive Patients Without(Standard) and With Tourniquet
Completed NCT00115726 - Trial Assessing the Effect of Preoperative Furosemide on Intraoperative Blood Pressure Phase 4
Recruiting NCT05513066 - Management Arterial Hypotension During Planned Caesarean Section, Intravenous Ephedrine/Phenylephrine Mixture Versus Intravenous Baby Noradrenaline
Completed NCT04089644 - Manual vs Closed-loop Control of Mean Arterial Pressure N/A