Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02437799
Other study ID # STH18900
Secondary ID
Status Completed
Phase N/A
First received April 1, 2015
Last updated October 12, 2016
Start date September 2015
Est. completion date December 2015

Study information

Verified date October 2016
Source Sheffield Teaching Hospitals NHS Foundation Trust
Contact n/a
Is FDA regulated No
Health authority United Kingdom: National Health Service
Study type Observational

Clinical Trial Summary

BACKGROUND:

Hypotension occurs commonly during spinal anaesthesia for caesarean section and may result in detrimental effects to the mother and foetus. A previous pilot study where images of the pulse oximeter waveform study were taken, found that the dicrotic wave moved away from the systolic wave during the onset of hypotension.

AIMS:

The investigators wish to download electronic data which describe the pulse oximeter pulse wave to more accurately assess movement of the diastolic wave relative to the systolic wave during spinal anaesthesia for caesarean section.

METHODOLOGY:

20 women undergoing caesarean section under spinal anaesthesia will be recruited by informed consent for this observational study. Data downloaded from the pulse oximeter will be analysed to identify movement of the dicrotic wave relative to the systolic wave and this will be related to changes in blood pressure.

EXPECTED OUTCOMES:

The investigators will establish best way to analyse changes in the pulse oximeter waveform and the relationship between changes in pulse oximeter waveform morphology and the onset of hypotension during spinal anaesthesia for caesarean section.

IMPLICATIONS:

Analysis of movement of the dicrotic wave could be used to anticipate and thus avoid severe hypotension during spinal anaesthesia for caesarean section.


Description:

BACKGROUND:

When a baby is delivered by a surgical procedure (a caesarean section) the women will usually have a spinal anaesthetic. With a spinal anaesthetic local anaesthetic is injected into the spinal fluid to make the woman numb from her chest to her feet allowing her to be comfortable but awake during the birth. One of the common side effects of a spinal anaesthetic is that the woman's blood pressure may fall making her feel unwell and (rarely) causing stress to the unborn baby.

During a caesarean section the blood pressure is usually measured every few minutes using a cuff around the upper arm. However, the blood pressure may fall too quickly to be detected in a timely fashion by this intermittent means. One of the other monitors used in all cases is called a pulse oximeter. When this is attached to the patient's finger it detects the pulse rate and how much oxygen there is in the blood. The pulse oximeter also produces an image of the pulse wave in the finger. There is one pulse wave for every time the heart beats and it has two components. The main part of the wave (the systolic wave) is caused by the heart beat and the second part of the wave (the dicrotic wave) is a result of some of the energy from the heart beat bouncing back from blood vessels.

In a previous study we used a digital camera to take images of the pulse oximeter monitor screen so that we could record changes in the shape of the pulse wave. We found that as patients' blood pressure fell the dicrotic wave moved further away from the systolic wave. We now intend to down load the electronic data that make up the pulse oximeter waveform, so that we can analyse the changes that occur more accurately.

We believe that falling blood pressure may be detected earlier using analysis of movement of the dicrotic wave than by our standard monitoring. This is because currently blood pressure is measured intermittently whereas the pulse oximeter waveform is displayed continuously. Drugs could then be given promptly to stop the blood pressure from falling so low that the woman feels unwell or the unborn baby is affected.

AIMS:

Our aim is to observe changes in the position of the dicrotic wave during spinal anaesthesia for caesarean section and relate these to the occurrence of low blood pressure.

METHODOLOGY:

Following ethical approval 20 women undergoing caesarean section under spinal anaesthesia will be recruited by written informed consent. In theatre the electronic data which describe the pulse oximeter waveform will be downloaded by means of a data logger. In parallel, we will manually record the other perioperative data including the blood pressure. We will then use the data to establish the best way of accurately and reproducibly identifying the dicrotic wave when it moves in relation to the onset of low blood pressure. As this is an observational study, the management of the case will be at the discretion of the attending anaesthetist in discussion with the patient and will not be altered by inclusion in the study.

EXPECTED OUTCOMES:

1. We will establish the best way to detect movement of the dicrotic wave.

2. We will establish the temporal relationship between movement of the dicrotic wave and fall in blood pressure during spinal anaesthesia for caesarean section.

IMPLICATIONS:

Anaesthetists will be able to use movement of the dicrotic wave to anticipate and avert low blood pressure during spinal anaesthesia for caesarean section.


Recruitment information / eligibility

Status Completed
Enrollment 20
Est. completion date December 2015
Est. primary completion date December 2015
Accepts healthy volunteers No
Gender Female
Age group 18 Years to 50 Years
Eligibility Inclusion Criteria:

Patients with an uncomplicated pregnancy presenting for elective caesarean section under spinal anaesthesia where surgery and anaesthesia are anticipated to be uncomplicated.

Exclusion Criteria:

Conditions which may impair the ability of the technology to read accurately such as:

- Reduced peripheral perfusion e.g. Raynaud's phenomenon

- Circulating pigments e.g. bilirubin

- Nail varnish that cannot be removed Diseases of pregnancy: e.g. pregnancy induced hypertension Significant co-existing maternal disease - e.g. congenital heart disease Inability to speak fluent English

Study Design

Observational Model: Cohort, Time Perspective: Prospective


Related Conditions & MeSH terms


Intervention

Other:
Dicrotic wave analysis
We will download data from the pulse oximeter that is being used to monitor the patient during their surgery.

Locations

Country Name City State
United Kingdom Sheffield NHS Trust Sheffield South Yorkshire

Sponsors (1)

Lead Sponsor Collaborator
Sheffield Teaching Hospitals NHS Foundation Trust

Country where clinical trial is conducted

United Kingdom, 

Outcome

Type Measure Description Time frame Safety issue
Primary 1. To download electronic data which describe the pulse oximeter pulse wave to accurately assess movement of the diastolic wave relative to the systolic wave during spinal anaesthesia for caesarean section. Data will be collected during planned caesarean section under spinal anaesthesia Data will be downloaded for approximately 20 minutes No
Secondary Time course of cardiovascular changes 1. To clearly document the time-course of cardiovascular changes and hypotension during spinal for caesarean section twenty minutes No
Secondary Preliminary cardiovascular data 2. To provide preliminary data to characterise cardiovascular changes during hypotension twenty minutes No
Secondary Vascular behaviour 4. To characterise changes in vascular behaviour, and to determine their time course, before and after onset of hypotension and the given treatment. twenty minutes No
See also
  Status Clinical Trial Phase
Completed NCT04062994 - A Clinical Decision Support Trial to Reduce Intraoperative Hypotension
Active, not recruiting NCT02016599 - Effects of Transitional Circulation in ELBW Infants
Recruiting NCT05836610 - Hydrocortisone Therapy Optimization During Hypothermia Treatment in Asphyxiated Neonates Phase 4
Suspended NCT02315937 - Hemodynamic Assessment During Spinal Anesthesia Using Transthoracic Echocardiography' N/A
Completed NCT03215797 - Phenylephrine or Norepinephrine for a Better Hemodynamic Stability Phase 3
Completed NCT02907931 - Carotid Doppler Ultrasound for the Measurement of Intravascular Volume Status N/A
Recruiting NCT02532270 - Detecting Hypotension By Continuous Non-invasive Arterial Pressure Monitoring N/A
Completed NCT02802683 - Hemodynamic Impact of Hyperbaric Versus Isobaric for Spinal Anesthesia During Cesarean Delivery Phase 4
Completed NCT01930227 - Transcutaneous Electrical Acupoint Stimulation(TEAS) for Hypotension After Spinal Anesthesia in Parturients N/A
Completed NCT02146898 - The Severity Of Hypotension Comparing Three Positions During Spinal Anesthesia For Cesarean Delivery N/A
Not yet recruiting NCT01941472 - Transcutaneous pO2, Transcutaneous pCO2 and Central Venous pO2 Variations to Predict Fluid Responsiveness N/A
Recruiting NCT01434251 - Treatment of Hypotension of Prematurity (TOHOP) N/A
Completed NCT01592669 - Passive Leg Raising Attenuates and Delays Tourniquet Deflation-induced Hypotension and Tachycardia N/A
Withdrawn NCT01183741 - Accuracy of Non-Invasive Blood Pressure Measurement in Adults Phase 3
Completed NCT00991627 - Different Approaches to Maternal Hypotension During Cesarean Section Phase 4
Withdrawn NCT00750516 - Lactic Acid Levels In Hypotensive Patients Without(Standard) and With Tourniquet
Completed NCT00115726 - Trial Assessing the Effect of Preoperative Furosemide on Intraoperative Blood Pressure Phase 4
Recruiting NCT05513066 - Management Arterial Hypotension During Planned Caesarean Section, Intravenous Ephedrine/Phenylephrine Mixture Versus Intravenous Baby Noradrenaline
Completed NCT04089644 - Manual vs Closed-loop Control of Mean Arterial Pressure N/A
Active, not recruiting NCT05250960 - Pre-epidural SCDs to Prevent Hypotension During Labor N/A