Official title:
Impact of Maternal Lateral Tilt on Cardiac Output During Caesarean Section Under Spinal Anaesthesia: A Prospective Observational Study
Background: Left uterine displacement (LUD) has been questioned as an effective strategy to prevent aortocaval compression after spinal anesthesia (SA) for cesarean delivery (CD). The investigators tested if LUD has a significant impact on cardiac output (CO) in patients undergoing CD under SA during continuous non-invasive hemodynamic monitoring. Methods: Forty-six patients were included in the final analysis. The investigators considered 4 timepoints of 5 minutes each: T1=baseline with LUD; T2=baseline without LUD; T3=after SA with LUD; T4=after SA without LUD. LUD was then repositioned for CD. Primary outcome was to test if CO decreased from T3 to T4. We also compared CO between T1 and T2 and other hemodynamic variables: mean, systolic and diastolic blood pressure (respectively MAP, SAP and DAP), heart rate (HR), stroke volume (SV), stroke volume variation (SVV), pulse pressure variation (PPV), contractility (dP/dt), dynamic arterial elastance (Eadyn) at the different timepoints. Data on fetal Apgar scores and umbilical arterial and venous pH were collecte
The primary outcome was to test if CO decreases significantly after LUD removal in patients under SA for CD. This is a prospective observational study. Data were gathered from pregnant patients who, in addition to standard monitoring, underwent perioperative non-invasive hemodynamic monitoring by ClearSight system on the Edwards Lifesciences HemoSphere platform (Edwards Lifesciences, Irvine, CA). The parameters were recorded at 20 seconds-intervals. The investigators considered 4 timepoints. T1 were the baseline values recorded for 5 minutes, after initial stabilization of parameters, with the patient laying down on the operating table with LUD. At T2, LUD was removed and we considered for the analysis hemodynamic data of the subsequent 5 minutes. The investigators indicated as T3 the 5 minutes following SA with a satisfactory sensory block and as T4 the subsequent 5 minutes following LUD removal. Figure 1 summarizes the timepoints of our analysis. LUD was accomplished by positioning a wooden wedge wrapped with cotton, to make it comfortable, and medical sheets with a measured angle of 15° under the right flank of the laying down patient. In all patients, after T4 the 15° wooden wedge was positioned again and surgery was performed with LUD. Anesthesia was standard spinal procedure, fluid management was left to the attending anesthesiologist. The attending anesthesiologist was blinded to the advanced hemodynamic parameters from the ClearSight system except for the continuous BP values. The investigators defined hypotension as an absolute value of MAP < 65 mmHg. This value was considered as trigger for the attending anesthesiologist for the administration of norepinephrine 5 mcg. Norepinephrine boluses were repeated to reach a MAP>65mmHg. Bradycardia was defined as a heart rate of < 60 bpm. Atropine 0.5 mg was administered for the treatment of bradycardia combined with hypotension, or for an absolute value of heart rate < 45 bpm. After delivery, Oxytocin was administered to facilitate the uterine contraction. We also evaluated the impact of maternal blood pressure and CO on fetal outcome collecting neonatal Apgar scores at 1 and 5 minutes after birth, and umbilical cord arterial and venous pH. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT05970770 -
Hypotension Prediction Index vs Norepinephrine Infusion for Prevention of Spinal Hypotension for Cesarean Delivery
|
Phase 4 | |
Recruiting |
NCT03626454 -
Norepinephrine Addition in Spinal Anesthesia of Caesarean Section
|
N/A | |
Completed |
NCT03834454 -
Bupivacaine 5 mg vs 7.5 mg for Spinal Anesthesia in Cesarean Delivery in Indonesian Population
|
N/A | |
Recruiting |
NCT05661942 -
Diltiazem in the Treatment of Atrial Fibrillation or Atrial Flutter With Rapid Ventricular Rate
|
Phase 4 | |
Recruiting |
NCT05079269 -
Pre-op Fluid Study
|
N/A | |
Completed |
NCT02967029 -
Effect of Controlled Hypotension on Cerebral Oxygen Saturation
|
Phase 4 | |
Recruiting |
NCT06334549 -
A Prospective Study of Vasopressor on Cerebral Oxygenation During General Anesthesia
|
Phase 4 | |
Not yet recruiting |
NCT03465943 -
Different Preloads for Prevention of Hypotension in Patients Undergoing Elective CS Under Intrathecal Anesthesia
|
Early Phase 1 | |
Not yet recruiting |
NCT03478618 -
Comparison of Different Protocols of Fluid Therapy in Severe Preeclamptic Patients Under Spinal Anesthesia
|
Early Phase 1 | |
Recruiting |
NCT06259760 -
AKI Risk Factors Analysis After Intentional Hypotensive Anesthesia
|
||
Recruiting |
NCT03743870 -
Spinal Anesthesia in Caesarean Section
|
||
Completed |
NCT02979405 -
Effectiveness of Phenylefrine in Prevention of Hypotension During Spinal Anesthesia for Cesarean Delivery
|
Phase 4 | |
Completed |
NCT05101291 -
Fractional Spinal Anesthesia and Systemic Hemodynamics in Frail Elderly Hip Fracture Patients.
|
N/A | |
Recruiting |
NCT04914234 -
Premedication With Atenolol Versus Metoprolol for Controlled Hypotensive Anesthesia During Nasal Surgeries
|
Phase 4 | |
Completed |
NCT05502146 -
Comparison of Two Different Norepinephrine Bolus Doses for Management of Spinal Anesthesia-Induced Maternal Hypotension
|
Phase 4 | |
Completed |
NCT05368376 -
Is Labetalol More Effective Than Metoprolol for Controlled Hypotensive Anesthesia During Endoscopic Nasal Surgeries?
|
Phase 4 | |
Completed |
NCT04865614 -
Comparison Between Inhalation and Intravenous Induction of Anaesthesia During Interventional Mitral Valve Repair
|