Hydrocephalus Clinical Trial
Official title:
Value of MRI CSF Flowmetry in Assessment of Grey Zone Hydrocephalic Patients
To evaluate accuracy of (MRI) cerebrospinal fluid flowmetry after shunt operation in patients with borderline (grey zone) hydrocephalus.
Hydrocephalus could be defined as disturbance of formation, flow or absorption of CSF. We
encounter some challenging cases with intermittent non specific symptoms as delayed
milestones and headache with concomitant imaging showing dilated ventricular system, so we
find ourselves hesitating to take the decision of surgical intervention to put shunt or not,
therefore MRI CSF flowmetry gives us a chance to overcome this problem. Phase contrast MR
imaging is a rapid, simple and non-invasive technique which is sensitive to even small CSF
flows, and can be used to evaluate CSF flow both qualitatively and quantitatively.
CSF flow measurement at the suspected level of obstruction gives reliable and reproducible
results for more accurate diagnosis and can be used to guide therapeutic decisions in a more
reliable manner, and follow up post treatment outcome.
With the CT and magnetic resonance imaging (MRI) techniques, it is possible to localize with
accuracy the exact site of blockage of flow to CSF. Hence classification is as follows: The
hydrocephalus may be due to 1) overproduction of CSF 2) obstructive 3) absorption defect.
Depending on the exact aetiology, a secondary classification could be added under the
following headings: 1) congenital, 2) acquired, eg; traumatic inflammatory, neoplastic, and
degenerative . Bypassing the site of obstruction to CSF flow by diverting the CSF from
ventricular cavity to a site where it is readily absorbed is the basic principle underlying
the treatment of hydrocephalus. Extensive range of complications has been reported for
shunting for hydrocephalus. They could be classified as mechanical or flow-related
complications as CSF over drainage leading to subdural hematoma, subdural collections,
low-pressure headaches cranial deformity, and asymmetrical drainage can lead to trapping or
isolation of a part of a ventricular system. The slit ventricular syndrome is a complication
related to absorption. Besides, ascites, loculations, hydrocele, perforation of the stomach,
large and small bowel are also described. The success rates of shunt operation for
hydrocephalus depend on the age of the patient and the reason why the shunt is needed.
Generally, there is around a 50% failure rate for ventriculoperitoneal shunts.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06040697 -
Formative Usability Assessment of Wireless Thermal Anisotropy Devices
|
||
Terminated |
NCT02408757 -
Sonographic Monitoring of Weaning of Cerebrospinal Fluid Drainages
|
||
Terminated |
NCT01863381 -
Comparison of Continuous Non-Invasive and Invasive Intracranial Pressure Measurement
|
N/A | |
Completed |
NCT00652470 -
A Study Comparing Two Treatments for Infants With Hydrocephalus
|
Phase 2 | |
Completed |
NCT00196196 -
A Precision and Accuracy Study of the Codman Valve Position Verification (VPV) System.
|
Phase 3 | |
Terminated |
NCT05501002 -
Pilot Study to Evaluate the CereVasc® eShunt® System in the Treatment of Communicating Hydrocephalus
|
N/A | |
Active, not recruiting |
NCT05068128 -
Combined Flow and Pressure Study of Craniospinal Dynamic
|
||
Completed |
NCT04496414 -
Bactiseal Catheter Safety Registry in China
|
||
Terminated |
NCT02900222 -
Study of Choroid Plexus Cauterization in Patients With Hydrocephalus
|
N/A | |
Recruiting |
NCT04099823 -
MR Evaluation of Cerebrospinal Fluid (CSF) Dynamics
|
N/A | |
Unknown status |
NCT02775136 -
An Evaluation of a Non-invasive Brain Monitor
|
N/A | |
Completed |
NCT00692744 -
Quality of Life in Elderly After Aneurysmal Subarachnoid Hemorrhage (SAH)
|
N/A | |
Recruiting |
NCT04758611 -
The ETCHES I Study (Endovascular Treatment of Communicating Hydrocephalus With an Endovascular Shunt)
|
N/A | |
Completed |
NCT03595033 -
Hydrocephalus iPad-App Based Intervention Study
|
N/A | |
Completed |
NCT04207229 -
CERTAS Programmable Valve Registry
|
||
Completed |
NCT01976559 -
Comparison of Continuous Noninvasive and Invasive Intracranial Pressure Measurement--Celda Infusion Subprotocol
|
N/A | |
Terminated |
NCT01973764 -
Intraventricular Drain Insertion: Comparison of Ultrasound-guided and Landmark-based Puncture of the Ventricular System
|
N/A | |
Completed |
NCT02381977 -
Prevalence of Acute Critical Neurological Disease in Children: a Global Epidemiological Assessment
|
N/A | |
Recruiting |
NCT06086561 -
Longitudinal Measurements of Flow in Cerebrospinal Fluid Shunts With a Wireless Thermal Anisotropy Measurement Device
|
N/A | |
Recruiting |
NCT05910944 -
European Study of Prodromal iNPH
|