Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01878383
Other study ID # DMID 11-0070
Secondary ID
Status Completed
Phase
First received
Last updated
Start date January 2014
Est. completion date December 31, 2019

Study information

Verified date August 2020
Source University of Alabama at Birmingham
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

PCR detection of HSV DNA shedding in the female genital tract using the GeneXpert system (Cepheid, Sunnyvale CA) will be compared with traditional (routine) PCR (pregnant and nonpregnant women) and with HSV culture (nonpregnant women). The GeneXpert system performs all sample-processing steps and real-time PCR in a single integrated cartridge. The standard cartridge is an inexpensive disposable plastic cartridge with filtration and ultrasonic lysis capabilities. It consists chiefly of several combined molded plastic components: a cartridge body containing eleven fluid reservoirs or chambers along with an attached PCR tube, a specialized valve body with an ultrasonic interface containing a sub-micron filter and glass lysis beads, and a rotary valve with an axial syringe barrel. The operation of the cartridge is simple. The rotary valve contains an inlet and an outlet port. Fluid such as a sample buffer can be drawn up into a syringe drive through the inlet port of the rotary valve and then dispensed into any other chamber within the cartridge by rotating the valve and expelling the fluid through the outlet port. The fluid can either be passed through a filter contained within the valve assembly or it can be passed directly into the next chamber without filtration, depending on the path that is chosen. The cartridge fluidics and subsequent real-time PCR all are performed within the GeneXpert instrument. The GeneXpert contains multiple modules (ICORE units) that can be independently programmed to drive the syringe/rotary valve, and to perform four-color real-time PCR. Each cartridge fits inside one module, and all processing, PCR, and analysis steps are performed automatically. Each ICORE module can be run and analyzed independently, so batching of samples is unnecessary.


Description:

Read more »
Read more »

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Genexpert assay


See more »

Sponsors (1)

Lead Sponsor Collaborator
University of Alabama at Birmingham

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Sensitivity of Detection of HSV DNA by GeneXpert PCR From Specimens Obtained From the Genital Tract of Non-pregnant Women in STI Clinics, as Compared With HSV Culture Assessing the vaginal specimen collected via a swab of non-pregnant women presenting to their provider at the time of active HSV outbreak with standard HSV culture compared to the assay of new device called a GeneXpert.
Percent of GeneXpert assessment in agreement with standard HSV culture, for subjects who were positive for HSV according to culture.
on day of enrollment
Primary Positive Percent Agreement of Detection of HSV DNA by GeneXpert PCR From Specimens Obtained From Genital Tract of Pregnant Women, as Compared With Routine PCR Detection of Viral DNA Detection of HSV DNA by GeneXpert PCR compared to routine PCR detection by viral DNA. Percent of GeneXpert assessment in agreement with routine PCR detection, for subjects who are positive for HSV according to routine PCR. DAY OF ENROLLMENT
Primary Negative Percent Agreement of Detection of HSV DNA by GeneXpert PCR From Specimens Obtained From Genital Tract of Pregnant Women, as Compared With Routine PCR Detection of Viral DNA Detection of HSV DNA by GeneXpert PCR compared to routine PCR detection by viral DNA. Percent of GeneXpert assessments in agreement with routine PCR detection, for subjects who were negative for HSV according to routine PCR. DAY OF ENROLLMENT
See also
  Status Clinical Trial Phase
Completed NCT00942084 - A Study to Describe the Pharmacokinetics of Acyclovir in Premature Infants (PTN_Acyclo) Phase 1
Completed NCT01431326 - Pharmacokinetics of Understudied Drugs Administered to Children Per Standard of Care
Completed NCT02452229 - Review of Human Herpes Viruses in Burns N/A
Terminated NCT00913692 - A Randomized Double-Blind Control-Comparison Crossover Trial of Oral Glutamine to Suppress Frequently Recurrent Herpes Labialis Phase 2
Withdrawn NCT01610765 - A Safety and Dose-Determining Study of CMX001 In Infants With Neonatal Herpes Simplex Virus (HSV) Infection Involving the Central Nervous System (CNS Disease) Phase 1/Phase 2
Recruiting NCT06435507 - Phase I Clinical Trial to Evaluate the Safety, Tolerability, and Pharmacokinetics of Single Doses of IM-250 in Healthy Volunteers Phase 1