Hemorrhage Clinical Trial
Official title:
Development of a Multiplex Precision Medicine System for Early Warning of Progression Toward Shock After Trauma: Non-invasive Measurement During Hepatectomy With Low Central Venous Pressure
Verified date | December 2021 |
Source | Dartmouth-Hitchcock Medical Center |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational |
Early detection of ongoing hemorrhage (OH) before onset of hemorrhagic shock is a universally acknowledged great unmet need, and particularly important after traumatic injury. Delays in the detection of OH are associated with a "failure to rescue" and a dramatic deterioration in prognosis once the onset of clinically frank shock has occurred. An early alert to the presence of OH would save countless lives. This is a single site study, enrolling 48 patients undergoing liver resection in a "no significant risk" prospective clinical trial to: 1) further identify a minimal subset of noninvasive measurement technologies necessary for the desired diagnostic performance, 2) validate the performance of our Phase I algorithm, and 3) re-train the algorithm to a Phase II human iteration. The main outcome variables are non-invasive measurements that will be used for machine learning, not real-time patient management. The data generated will be used later for discovery and validation in traditional and innovative machine learning.
Status | Terminated |
Enrollment | 7 |
Est. completion date | April 15, 2021 |
Est. primary completion date | April 15, 2021 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility | Inclusion Criteria: 1. Adults 18 years or older 2. Patients undergoing liver resection. 3. Ability to give informed consent. Exclusion Criteria: 1. Pre-existing systemic illness, likely to alter systemic cardiovascular response to hemorrhage. Including congestive heart failure, and a paced cardiac rhythm. 2. Pregnant 3. Prisoner status |
Country | Name | City | State |
---|---|---|---|
United States | The Ohio State University Comprehensive Cancer Center | Columbus | Ohio |
Lead Sponsor | Collaborator |
---|---|
Dartmouth-Hitchcock Medical Center | Dartmouth College, Ohio State University, United States Department of Defense |
United States,
Belle A, Ansari S, Spadafore M, Convertino VA, Ward KR, Derksen H, Najarian K. A Signal Processing Approach for Detection of Hemodynamic Instability before Decompensation. PLoS One. 2016 Feb 12;11(2):e0148544. doi: 10.1371/journal.pone.0148544. eCollection 2016. — View Citation
Convertino VA, Moulton SL, Grudic GZ, Rickards CA, Hinojosa-Laborde C, Gerhardt RT, Blackbourne LH, Ryan KL. Use of advanced machine-learning techniques for noninvasive monitoring of hemorrhage. J Trauma. 2011 Jul;71(1 Suppl):S25-32. doi: 10.1097/TA.0b013e3182211601. Review. — View Citation
Convertino VA. Blood pressure measurement for accurate assessment of patient status in emergency medical settings. Aviat Space Environ Med. 2012 Jun;83(6):614-9. — View Citation
Kim SH, Lilot M, Sidhu KS, Rinehart J, Yu Z, Canales C, Cannesson M. Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Anesthesiology. 2014 May;120(5):1080-97. doi: 10.1097/ALN.0000000000000226. Review. — View Citation
Parks JK, Elliott AC, Gentilello LM, Shafi S. Systemic hypotension is a late marker of shock after trauma: a validation study of Advanced Trauma Life Support principles in a large national sample. Am J Surg. 2006 Dec;192(6):727-31. — View Citation
Shackelford SA, Colton K, Stansbury LG, Galvagno SM Jr, Anazodo AN, DuBose JJ, Hess JR, Mackenzie CF. Early identification of uncontrolled hemorrhage after trauma: current status and future direction. J Trauma Acute Care Surg. 2014 Sep;77(3 Suppl 2):S222-7. doi: 10.1097/TA.0000000000000198. Review. — View Citation
Soller BR, Yang Y, Soyemi OO, Ryan KL, Rickards CA, Walz JM, Heard SO, Convertino VA. Noninvasively determined muscle oxygen saturation is an early indicator of central hypovolemia in humans. J Appl Physiol (1985). 2008 Feb;104(2):475-81. Epub 2007 Nov 15. — View Citation
Wo CC, Shoemaker WC, Appel PL, Bishop MH, Kram HB, Hardin E. Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness. Crit Care Med. 1993 Feb;21(2):218-23. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Non-invasive measurements that will be used for machine learning | Continuous-wave Near-Infrared Spectroscopy (CW-NIRS) | 2-3 hours | |
Primary | Non-invasive measurements that will be used for machine learning | Electrical Impedance Tomography | 2-3 hours | |
Primary | Non-invasive measurements that will be used for machine learning | Electrical Impedance Spectroscopy | 2-3 hours | |
Primary | Non-invasive measurements that will be used for machine learning | Intrathoracic Hemodynamic Bioreactance Signatures | 2-3 hours |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02815670 -
Reversal Dabigatran Anticoagulant Effect With Idarucizumab
|
Phase 3 | |
Completed |
NCT04588350 -
Clinical Investigation Evaluating a New Autotransfusion Device in Cardiac Surgery
|
N/A | |
Recruiting |
NCT02972385 -
Pharmacogenomics of Warfarin in Hispanics and Latinos
|
||
Completed |
NCT02554006 -
Predischarge Bundle to Minimize Negative Impact on Quality of Life of Nuisance Bleedings
|
N/A | |
Completed |
NCT02569606 -
Transfusion and Coagulation Management in Trauma Patients After the Introduction of a Coagulation Algorithm
|
||
Recruiting |
NCT02446730 -
Efficacy and Safety of BiomatrixTM Stent and 5mg-Maintenance Dose of Prasugrel in Patients With Acute Coronary Syndrome
|
Phase 4 | |
Completed |
NCT01955720 -
Safety, Tolerability, PK and PD of BI 655075 and Establishment of BI 655075 Dose(s) Effective to Reverse Prolongation of Blood Coagulation Time by Dabigatran
|
Phase 1 | |
Completed |
NCT01935427 -
Comparison of Compensatory Reserve Index to Intravascular Volume Change and Stroke Volume
|
N/A | |
Recruiting |
NCT01709786 -
Non-Invasive Hemoglobin Monitoring in Patients With Hemorrhage
|
N/A | |
Completed |
NCT01191554 -
Dose-ranging Study of Tranexamic Acid in Valve Surgery
|
N/A | |
Completed |
NCT01210417 -
Trauma Heart to Arm Time
|
N/A | |
Completed |
NCT01136590 -
Multicenter, Randomized Placebo-controlled Clinical Trial to Evaluate the Effect of Perioperative Use of Tranexamic Acid on Transfusion Requirements and Surgical Bleeding in Major Spine Surgery
|
Phase 4 | |
Completed |
NCT01085006 -
The Effect of Tranexamic Acid on Postpartum Hemorrhage During and After Cesarean Delivery
|
Phase 1/Phase 2 | |
Completed |
NCT00700141 -
Non-Interventional Study About Treatment of Hemorrhages in Thyroid Surgery With TachoSil®
|
N/A | |
Completed |
NCT00375466 -
Tranexamic Acid, Hemorrhage and Transfusions After Combined Aortic Valve Replacement and Coronary Artery Bypass Surgery.
|
N/A | |
Completed |
NCT00479362 -
Anticoagulant Therapy During Pacemaker Implantation
|
Phase 4 | |
Completed |
NCT00147420 -
RCT of Zhi Byed 11 (ZB11) Versus Misoprostol in Tibet
|
N/A | |
Recruiting |
NCT05945680 -
Tranexamic Acid in Breast Esthetic Surgery.
|
Phase 4 | |
Completed |
NCT03273322 -
Assessment of Dual Antiplatelet Therapy Versus Rivaroxaban In Atrial Fibrillation Patients Treated With Left Atrial Appendage Closure
|
Phase 2/Phase 3 | |
Withdrawn |
NCT05672407 -
The Role of Local Tranexamic Acid on Periorbital Oculoplastic Surgery
|
Phase 4 |