The Application of Pleth Variability Index in Continuous Monitoring Volume Status in Patients Undergoing Intestinal Tumor Surgery
To assess the value of using pleth variability index(PVI) to monitor the patient's intra-operative volume status continuously by observing the application of stroke volume variation(SVV) and PVI and their correlation in patients undergoing intestinal tumor surgeries.
Objective: To assess the value of using PVI to monitor the patient's intra-operative volume
status continuously by observing the application of stroke volume variation(SVV) and pleth
variability index(PVI) and their correlation in patients undergoing intestinal tumor
surgeries.
Methods: 50 patients undergoing elective intestinal tumor surgery were enrolled, ASAⅠ-Ⅲ,
aged 18-65 years. After the induction of general anesthesia, cardiac index(CI), cardiac
output(CO), stroke volume variability(SVV), stroke volume index(SVI) were monitored with
Vigileo system, while pleth variability index(PVI) and perfusion index(PI) were monitored
with Massion Radical 7 system. During the surgery, goal directed fluid therapy was conducted
according to the data of CI、SVI and SVV. Heart rate(HR), mean arterial pressure(MAP),
central venous pressure(CVP), CO, CI, SVI, SVV, PI, PVI were recorded while after the
induction of anesthesia(T1), making surgical incision(T2), performing intestinal
anastomosis(T3) and closing the abdominal incision(T4). And we calculate the correlation of
SVV and PVI using Pearson Correlation Analysis at different time points.
;
Observational Model: Case-Only, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04972266 -
The EU Hyprotect Registry
|
||
Not yet recruiting |
NCT03691103 -
Record and Analyze the Data of Patient Undergoing Anesthesia for Laparoscopic Cholecystectomy From Patient Monitoring Instruments
|
||
Active, not recruiting |
NCT04281771 -
Assessment of Paravalvular Leak After TAVI by Hemodynamic Measurements and Cardiac MRI
|
N/A | |
Recruiting |
NCT05543824 -
Hemodynamic Impact of Epidural Anesthesia in Relation to Age in Pediatric Patients.
|
||
Terminated |
NCT03208023 -
RESIPI for Reducing Perioperative Major Adverse Cardiac Events
|
N/A | |
Not yet recruiting |
NCT00966147 -
Advanced Hemodynamic Monitoring for Goal-directed Hemodynamic Management During Radical Cystectomy
|
N/A | |
Recruiting |
NCT05445037 -
Hemodynamic and Cerebral Effects Evaluation in Anesthesia
|
N/A | |
Completed |
NCT04517409 -
Goal-directed Hemodynamic Therapy in Patiens Undergoing Major Hepatic Resection
|
N/A | |
Terminated |
NCT02950649 -
Evaluation of Clinical Impact of Non-Invasive Hemodynamic Monitoring to Optimize Perioperative Care
|
||
Completed |
NCT04648293 -
Starling Registry Study
|
||
Completed |
NCT04535115 -
Tidal Volume Challenge and Lung Recruitment Maneuver (TIDALREC): the Reliability of Pulse Pression Variation or Stroke Volume Variation on Fluid Responsiveness.
|
N/A | |
Recruiting |
NCT05418881 -
Evaluation and Implementation of Mobile Tracking Devices to Increase Safety in Hospitalized Patients (MONITOR)
|
N/A | |
Completed |
NCT05779683 -
Caretaker in the Cardiovascular Intensive Care Unit (CVICU)
|
||
Terminated |
NCT04996420 -
Goal Directed Fluid Therapy Versus Liberal Fluid Regimen in Primary Elective Hip Artrhoplasty
|
N/A | |
Recruiting |
NCT02156856 -
Stroke Volume Analysis During Aortic Valve Replacement Trial
|
N/A | |
Completed |
NCT00624494 -
Single Transpulmonary Thermodilution and Continuous Monitoring of Central Venous Oxygen Saturation During Off-pump Coronary Surgery
|
N/A | |
Recruiting |
NCT04109339 -
Effects of Oxytocin on Hemodynamics in Patients Undergoing Laparoscopic Myomectomy
|
N/A | |
Completed |
NCT04241926 -
Single-lumen 5Fr and Triple-lumen 6Fr PICCs Are Accurate for Hemodynamic Measurement by Transpulmonary Thermodilution.
|
N/A | |
Completed |
NCT05365113 -
Comparison of Hemodynamic Effects of Two Modalities of Alveolar Recruitment Maneuvers in Major Abdominal Surgery Patients
|
N/A | |
Completed |
NCT03893513 -
Comparison of Transthoracic Electrical Bioimpedance and Pulse Contour Analysis in Renal Transplantation Patients
|