Clinical Trials Logo

Clinical Trial Summary

Robotic-assisted laparoscopic prostatectomy (RALP) is a surgical method with good short-term results and accepted as the gold standard because of its minimal invasiveness. The pneumoperitoneum and deep Trendelenburg position (at least 25°-45° upside down) required for RALP surgeries can cause significant pathophysiological changes in both the pulmonary and cardiac systems, as well as complicate hemodynamic management. In this study, investigators aimed to determine the changes in the cardiovascular system during deep Trendelenburg position with the hemodynamic parameters monitored by the pressure record analytical method (PRAM) and the Longitudinal Strain measured with simultaneous transesophageal echocardiography.


Clinical Trial Description

RALP is the gold standard surgical technique in prostate surgery. Many Robotic-laparoscopic surgical techniques also require the intraoperative deep Trendelenburg position. However, the possible side effects of the deep Trendelenburg position on the cardiovascular system during surgery are unknown. Although the Trendelenburg position is a life-saving maneuver in hypovolemic patients, it also carries undesirable risks. Although the increase in venous return is expected to protect the cardiac output (CO) in the deep Trendelenburg position, the increase in intrathoracic pressure due to the intraperitoneal pressure may cause deterioration in venous return and a decrease in CO . In addition, the changing heart configuration in the deep Trendelenburg position may also cause an increase in the workload of the heart. Therefore, the need to evaluate hemodynamic management with advanced monitoring techniques, including fluid therapy in the perioperative period, has arisen in patients undergoing RALP. The pressure Recording Analytical Method (PRAM), is one of the most up-to-date monitoring methods designed for continuous CO measurement derived from the arterial pressure wave analysis, with a high signal sampling rate (1000 Hz). Many studies have shown that PRAM is a reliable monitoring method in major surgery. Cardiac Cycle Efficiency (CCE), which the PRAM method adds to our daily practice, is an index that defines hemodynamic performance in terms of energy consumption and efficiency. It can be expressed as the ratio of systolic energy performance to the total energy expenditure of the cardiac cycle and indicates the ability of the cardiovascular system to maintain homeostasis at different energy levels. However, data on how cardiac functions change in the deep Trendelenburg position are still limited. In this study, investigators aimed to demonstrate the reliability of the CCE value through its correlation with the Longitudinal Strain (LS) by observing the effect of the deep Trendelenburg position in RALP surgeries on cardiac functions using PRAM and Transesophageal Echocardiography (TEE). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05685979
Study type Observational
Source Acibadem University
Contact
Status Completed
Phase
Start date May 1, 2022
Completion date October 15, 2022

See also
  Status Clinical Trial Phase
Completed NCT03653910 - Effect-site Concentration of Remifentanil for Double-lumen Tubes Intubation: Airtraq VS Macintosh Laryngoscope N/A
Completed NCT06000098 - Consol Time and Acute Kidney Injury in Robotic-assisted Prostatectomy
Recruiting NCT02565251 - Volemic Resuscitation in Sepsis and Septic Shock N/A
Terminated NCT02365688 - Hemodynamic Response During Goal Directed Fluid Therapy in the OR N/A
Completed NCT01559675 - Trial Comparing Low Dose and High Dose Steroids in Patients Undergoing Colorectal Surgery N/A
Completed NCT01605279 - Dobutamine Versus Placebo for Low Superior Vena Cava Flow in Newborns Phase 2
Recruiting NCT04010058 - Postoperative Continuous Non-invasive Haemodynamic Monitoring on the Ward N/A
Completed NCT06268275 - Comparison of Effects of Scalp Block and Intravenous Esmolol on Hemodynamic Response Following the Skull Pins Application for Elective Supratentorial Craniotomy N/A
Recruiting NCT04926220 - Dynamic Estimation of Cardiac Output in the Operating Room
Not yet recruiting NCT05003011 - Correlation of Hemodynamics Via Pulmonary Artery Catherization and the Cardiospire
Completed NCT03599440 - Effect of Extended Infusion Lines on Pulse Contour-based Measurements
Completed NCT05035485 - Maternal Cardiac Output Response to Rescue Norepinephrine and Phenylephrine Boluses in Patients With Severe Preeclampsia N/A
Not yet recruiting NCT04227821 - Hemodynamic Optimalization in Pediatric Patients
Completed NCT05481047 - Prevention or Treatment of Arterial Hypotension and Oxygen Cerebral Saturation During Major Abdominal Surgery N/A
Completed NCT06158165 - Evaluating The Cardiovascular Effects of Tourniquet Application
Not yet recruiting NCT04076709 - Cardiovascular Effects of Muscle Relaxation During Laparoscopic Surgery Phase 4
Not yet recruiting NCT03828032 - Multi-parameters'Change Process During Dehydration Therapy on Brain Edema Patients. N/A
Completed NCT04089098 - VOLume and Vasopressor Therapy in Patients With Hemodynamic instAbility
Recruiting NCT05570682 - Manually Controlled Infusion vs Target Controlled Infusion for StrokeThrombectomy N/A
Completed NCT04574908 - A Pilot Trial of Continuous Portable Postoperative Hemodynamic And Saturation Monitoring On Hospital Wards N/A