Hemodynamic Instability Clinical Trial
Official title:
Hemodynamic Study With Pressure Recording Analytical Method (PRAM) of the Cardiovascular Response to the Positioning of the Extraglottic Device in Gynecological Surgery
The purpose of the study will be to record the hemodynamic response measured by traditional methods (non-invasive blood pressure and ECG) and Pressure Recording Analytical Method in patients undergoing laryngeal mask placement compared with the hemodynamic response measured in patients undergoing laryngoscopy and tracheal intubation for performing surgery in gynecological area and assess the differences with the two methods.
Introduction Laryngoscopy and tracheal intubation may cause significant hemodynamic changes
in the patient and induce cardiovascular complications.
Numerous studies have sought methods to reduce this risk (1-5). The extraglottic not
involving either laryngoscopy or their passage through the vocal cords, have proven
protective of the possible cardiovascular complications resulting from the placement of
respiratory prosthesis (6,7).
Measurements of hemodynamic changes resulting from the procedures for airway management with
extraglottic have not previously been carried out.
The MostCare (Vytech, Vygon Italia srl, Padova, Italy) is a monitor provided for more than
10 years at the obstetric gynecological anesthesia unit able to evaluate the hemodynamic
changes in a patient based on the Pressure Recording Analytical Method (PRAM).
This is a measurement method of the cardio-circulatory performance of a patient that does
not require calibration and / or insertion of a pre-estimated data because the method of
analysis of the wave form of the arterial pressure is developed completely a priori (8). The
measurement derives from the simultaneous analysis of the components of a pulsatile flow and
the continuous flow as a ratio between the area under the curve of the pulsatile portion of
the systolic pressure and the characteristic impedance Z (t). The PRAM method has proven
effective in many clinical settings (9).
The Medical Device (DM) will be used in accordance with the indications of use for which it
has acquired the CE mark. A morphology detection system linked to high blood pressure curve
detected through non-invasive Masimo oximetry system supplied to the Hospital will be used
Purpose of the study The purpose of the research will be to record the hemodynamic response
measured by traditional methods (non-invasive blood pressure and ECG) and PRAM method in
patients undergoing placement laryngeal mask compared with the hemodynamic response measured
in patients undergoing laryngoscopy and tracheal intubation for performing surgery in
gynecological area and assess the differences with the two methods
Methods This will be a prospective observational study. Data will be collected from all
consecutive patients undergoing general anesthesia for gynecologic surgery for a period of 3
months or until the minimum number of 94 patients (see section statistical analysis).
In the operating room the patient will undergo to active pre-warming with hot air,
peripheral venous cannulation and premedication with midazolam 0,04 mg/kg, and fentanyl 1.5
mcg/kg body weight. After the positioning of the standard monitoring systems (ECG,
Non-Invasive Blood Pressure, Pulseoximetry, Neuromuscular Transmission), the signal from the
Pulseoximetry will also be analyzed by the MostCare monitoring system that allows to apply
the measuring method PRAM noninvasively.
After 3 minutes of high flows O2, propofol 2 mg/kg body weight and rocuronium 0.9 mg/kg body
weight will be administered sequentially to the patient. Anesthesia will be maintained with
propofol continuous infusion (9-12 mg/kg body weight /hour) and remifentanil continuous
infusion (0.2 mcg/kg body weight /minute ). At the disappearance of the adductor muscle
response to electrical stimulation of the thumb "Train of four" (TOF) applied to the ulnar
nerve the positioning maneuver of the respiratory device will be performed:
- with direct laryngoscopy in the case of endotracheal intubation
- with direct insertion in the case of laryngeal mask placement. Proper placement will be
evaluated by chest auscultation, spirometry and analysis of the concentration and the
carbon dioxide curve in exhaled gases.
The data obtained from the PRAM and the usual monitoring will be recorded on a special sheet
by an outside observer.
In the case of failed positioning of the respiratory device, the procedure will be repeated
and in case of further failure will proceed as indicated by national and hospital guidelines
(10), but the patient will still be excluded from the study ..
The choice of the respiratory device will depend on the type of intervention scheduled in
the operating program.
The hemodynamic and monitoring data will be recorded every minute for 5 minutes for each
patient.
The study duration will be 3 months (or in any case until reaching the minimum number of 94
cases).
The patients will be divided, retrospectively, in two groups according to the type of device
used for airway management.
The two groups will be compared on the basis of age and anthropometric parameters. An
analysis of the hemodynamic response of the two groups of patients to the positioning of the
respiratory device will then conduct.
Statistical analysis A recent study (11), that analyzed the cardiac index changes in
response to tracheal intubation with laryngoscope Mcintosh in comparison to the video
laryngoscope laryngoscopy, showed a difference of 1 L/min/m2 (from 3.1±0.6 to 4.3±1.4 with
laryngoscope McIntosh vs 3.0±0.3 to 3.2 ± 1.1 with videolaryngoscope).
Therefore, to test the hypothesis that the cardiac index difference using the airway
management with traditional intubation compared to the use of the laryngeal mask is greater
than or equal to 1 L/min/m2, having fixed the first type error to the 5% and the study power
to 80%, it is possible to calculate that the sample size needed for a one-tailed test is
represented by 47 patients per group.
The average of the data collected in each group of patients will be compared with Student's
t test.
Expected results To verify, in two of homogeneous population groups for anthropometric and
clinical data, the least impact on the cardiovascular system produced by the placement of
laryngeal mask compared to that induced by endotracheal intubation with conventional
laryngoscopy taking advantage of non-invasive hemodynamic monitoring system of the pulse
oximetry MostCare (methodology PRAM) ever tested in this field.
Also to check the hemodynamic impact of any repeated attempts to both of the above maneuvers
for airway management.
Ownership of the results will be accredited by the principal investigator on behalf of the
AOU Careggi and the University of Florence as headings of him which has neither received nor
will receive any fee for the conduct of the study.
;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Prevention
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03653910 -
Effect-site Concentration of Remifentanil for Double-lumen Tubes Intubation: Airtraq VS Macintosh Laryngoscope
|
N/A | |
Completed |
NCT06000098 -
Consol Time and Acute Kidney Injury in Robotic-assisted Prostatectomy
|
||
Recruiting |
NCT02565251 -
Volemic Resuscitation in Sepsis and Septic Shock
|
N/A | |
Terminated |
NCT02365688 -
Hemodynamic Response During Goal Directed Fluid Therapy in the OR
|
N/A | |
Completed |
NCT01559675 -
Trial Comparing Low Dose and High Dose Steroids in Patients Undergoing Colorectal Surgery
|
N/A | |
Completed |
NCT01605279 -
Dobutamine Versus Placebo for Low Superior Vena Cava Flow in Newborns
|
Phase 2 | |
Recruiting |
NCT04010058 -
Postoperative Continuous Non-invasive Haemodynamic Monitoring on the Ward
|
N/A | |
Completed |
NCT06268275 -
Comparison of Effects of Scalp Block and Intravenous Esmolol on Hemodynamic Response Following the Skull Pins Application for Elective Supratentorial Craniotomy
|
N/A | |
Recruiting |
NCT04926220 -
Dynamic Estimation of Cardiac Output in the Operating Room
|
||
Not yet recruiting |
NCT05003011 -
Correlation of Hemodynamics Via Pulmonary Artery Catherization and the Cardiospire
|
||
Completed |
NCT03599440 -
Effect of Extended Infusion Lines on Pulse Contour-based Measurements
|
||
Completed |
NCT05035485 -
Maternal Cardiac Output Response to Rescue Norepinephrine and Phenylephrine Boluses in Patients With Severe Preeclampsia
|
N/A | |
Not yet recruiting |
NCT04227821 -
Hemodynamic Optimalization in Pediatric Patients
|
||
Completed |
NCT05481047 -
Prevention or Treatment of Arterial Hypotension and Oxygen Cerebral Saturation During Major Abdominal Surgery
|
N/A | |
Completed |
NCT06158165 -
Evaluating The Cardiovascular Effects of Tourniquet Application
|
||
Not yet recruiting |
NCT04076709 -
Cardiovascular Effects of Muscle Relaxation During Laparoscopic Surgery
|
Phase 4 | |
Completed |
NCT04089098 -
VOLume and Vasopressor Therapy in Patients With Hemodynamic instAbility
|
||
Not yet recruiting |
NCT03828032 -
Multi-parameters'Change Process During Dehydration Therapy on Brain Edema Patients.
|
N/A | |
Recruiting |
NCT05570682 -
Manually Controlled Infusion vs Target Controlled Infusion for StrokeThrombectomy
|
N/A | |
Completed |
NCT04574908 -
A Pilot Trial of Continuous Portable Postoperative Hemodynamic And Saturation Monitoring On Hospital Wards
|
N/A |