Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT04611555
Other study ID # B3002020000137
Secondary ID
Status Recruiting
Phase
First received
Last updated
Start date August 31, 2020
Est. completion date June 2022

Study information

Verified date April 2021
Source University Hospital, Antwerp
Contact Ellen Andries
Phone 003232757372
Email ellen.andries@uza.be
Is FDA regulated No
Health authority
Study type Observational [Patient Registry]

Clinical Trial Summary

The current project proposes a multi-center prospective follow-up cohort study aiming to realize an international framework to classify human functioning and disability in Cochlear Implant (CI) recipients using a standardized ICF framework. For this, ICF qualifiers which denote the magnitude of the level of health or severity of the problem will be quantified to enable comparison of data across countries and health-care disciplines. Adult subjects (≥18 years old) eligible for cochlear implantation, considering the local criteria of reimbursement, will be assessed one month preoperatively and six months post the activation of the speech processor using three audiological examinations, evaluating the participants' localization abilities, speech recognition and hearing thresholds, and six questionnaires, each evaluating different aspects of daily life functioning and disability in hearing-impaired persons.


Recruitment information / eligibility

Status Recruiting
Enrollment 100
Est. completion date June 2022
Est. primary completion date June 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. General - Adults aged 18 years or older with postlingual HL - Signed and dated informed consent, informed permission and/or minors assent. - Willingness to participate in evaluations, test sessions, and medical follow-up sessions as defined in the protocol. - Physical and mental competence to participate in fitting of the device and follow-up sessions as defined in the protocol. - Fluency in the language of the implanting centre. 2. Audiological - Completion of hearing assessment battery showing suitability of the CI candidates. - Compliance with cochlear implant candidate selection criteria of the implanting centre. - First cochlear implantation 3. Medical - Patent cochlea, as evidenced by High-resolution computed tomography (HRCT) and/or Magnetic Resonance Imaging (MRI). Exclusion Criteria: 1. General - Re-implantation of the cochlear implant - No motivation to participate in the study and/or unreasonable expectations. 2. Medical - Presence of contra-indications for surgery in general and cochlear implantation in particular. - Presence of central auditory lesions. - Autoimmune disease, meningitis or ossification of the cochlea. - Radiological evaluation indicating malformation or obstruction of the cochlea. - Unstable psychological status. - Any disorder that may relate to an increased risk of skin flap problems - Having received chemotherapy - Be a burn victim 3. Use of one of the following electrodes for implantation - Compressed - Split - Any type of custom made electrodes

Study Design


Related Conditions & MeSH terms


Locations

Country Name City State
Australia Fiona Stanley Fremantle Hospital Group Perth
Belgium University Hospital Antwerp Edegem
Germany University Clinic of Würzburg Würzburg
Poland World Hearing Centre Kajetany
Spain Hospital La Paz Madrid

Sponsors (5)

Lead Sponsor Collaborator
University Hospital, Antwerp Fiona Stanley Hospital, Hospital Universitario La Paz, World Hearing Centre, Wuerzburg University Hospital

Countries where clinical trial is conducted

Australia,  Belgium,  Germany,  Poland,  Spain, 

Outcome

Type Measure Description Time frame Safety issue
Primary Change in Work Rehabilitation Questionnaire (WORQ) The WORQ was divided into two sections. Section one contains 18 sociodemographic and work-related questions regarding the four environmental categories from the brief ICF Core Set. The six categories from activities and participation that describe vocational education or work situations namely were also included in section one. In the main section of WORQ, 36 questions were phrased representing 34 categories. The WORQ has been revised to match the core needs of the cochlear implant ICF codes. The revised version includes 4 items in the first section and 14 items in the main section, taking less than 5 minutes to complete. One month preoperatively and six months post the activation of the speech processor
Primary Change in Abbreviated Profile of Hearing Aid Benefit (APHAB) The APHAB is a 24-item questionnaire derived from the original 66-item Profile of Hearing Aid Benefit. The self-assessment instrument evaluates hearing impairment in real-life situations with and without hearing aids. Participants have to rate how often a given statement is true in their daily life, based on the following seven response alternatives: always (99%), almost always (87%), generally (75%), half-the-time (50%), occasionally (25%), seldom (12%) and never (1%). Ease of communication, reverberation, background noise and aversiveness of sounds make up the four subscales of APHAB. In the first three subscales, higher scores suggest less hearing disability, while lower scores indicate less hearing disability in the aversiveness subscale. The APHAB typically requires 10 minutes or less to complete. One month preoperatively and six months post the activation of the speech processor
Primary Change in the Audio Processor Satisfaction Questionnaire (APSQ) The APSQ is a general questionnaire which is designed to assess the handling hearing devices, taking 5 minutes to complete. It assesses the wearing comfort, sound quality, and other device-specific factors related to the audio processor with 15 items on a VAS scale from 0 ('does not agree at all') to 10 ('fully agrees'). If an item does not apply to the subject, then the subject can tick the 'not applicable' option. The maximum number of incomplete answers for the validation analyses is set at three items per subject; if this number exceeds, then the subject shall be excluded. Hence, if participants do not wear at least one hearing device preoperatively, they will only complete in the questionnaire 6 months postactivation. One month preoperatively and six months post the activation of the speech processor
Primary Change in the Speech, Spatial, and Qualities of Hearing Questionnaire with 12 items (SSQ12) The SSQ12 is designed to measure self-reported auditory disability across a wide variety of domains, reflecting the reality of hearing in the everyday world. It takes approximately 5 minutes to complete and it covers: hearing speech in a variety of competing contexts, the directional, distance, and movement components of spatial hearing, segregation of sounds and attending to simultaneous speech streams, ease of listening, the naturalness, clarity, and identifiability of different speakers, different musical pieces and instruments, and different everyday sounds.
The SSQ12 consists of 12 questions that the subjects score on a scale from 0 (not at all) to 10 (perfectly). The total score is the sum of all items and can range between 0 and 120.
One month preoperatively and six months post the activation of the speech processor
Primary Change in the Hearing Implant Sound Quality Index 19 (HISQUI19) The HISQUI19 is a self-administered questionnaire to quantify the individual perceived sound quality of hearing implanted patients in daily life. The questionnaire consists of 19 seven-level Likert items ranging from "always (99%)" to "never (1%)", taking approximately 10 minutes to complete. Added percentage values support the answering. The total score is the sum of all items and ranges from 19 to 133 points. Missing data and the answer option ´not applicable' (N/A) are treated as ´missing values'. The maximum number of incomplete answers are set at three items per subject; if this number exceeds the subject shall be excluded. One month preoperatively and six months post the activation of the speech processor
Primary Change in Pure tone audiometry Pure tone audiometry will be performed according to current clinical standards (ISO 8253-1, 2010) by an experienced Good Clinical Practice (GCP) certificated audiologist (Master of science). Pre- and postoperatively, best-aided pure tone audiometry will be measured at 500, 1000, 2000, 4000 and 8000 Hz using warble tones in sound field in a sound treated booth. The loudspeaker will be placed in front of the participant at ear level at 1 meter distance. The best-aided pure tone average (PTA4) will be calculated by averaging participants' hearing thresholds at 500, 1000, 2000 and 4000 Hz in best-aided condition. One month preoperatively and six months post the activation of the speech processor
Primary Change in Speech intelligibility Speech intelligibility will be evaluated in quiet, using disyllables in Spanish and monosyllables in the other languages, and in noise, using sentences. These tests will be performed pre- and postoperatively in best-aided situation according to current clinical standards (ISO 8253-1, 2010). Participants will be sitting in front of the loudspeaker, positioned at ear level, at a one-meter distance. They will be instructed to repeat the speech stimuli they hear. Speech materials and assessment methods are aligned across the different centers cooperating in this study to obtain comparable results. One month preoperatively and six months post the activation of the speech processor
Primary Change in Sound localization Each center will use its own particular localization set-up. Centers not disposing of an appropriate set-up will only use the SSQ12 spatial subscale. The other centers use both the subjective SSQ12 and the objective localization test. One month preoperatively and six months post the activation of the speech processor
Secondary Change in the Nijmegen Cochlear Implant Questionnaire (NCIQ) The NCIQ is a disease-specific measure for QOL and focuses on the needs of CI recipients. It consists of 60 items, taking approximately 15 minutes to complete and it is categorized in the following subdomains: Sound perception basic, Sound perception advanced, Speech production, Self-esteem, Activity and Social interactions. Each subdomain contains 10 items. 55 of the total of 60 items are formulated as statements with 5 answer categories to indicate the degree to which the statement is true: never (1), sometimes (2), often (3), mostly (4), and always (5). The other 5 items will be answered according to the CI user's ability to perform the action in question: no (1), poorly (2), moderate (3), adequate (4), and good (5). If a statement does not apply to a patient, a sixth answer can be given: "not applicable." Missing values and the response category "not applicable" will be both treated as not completed. One month preoperatively and six months post the activation of the speech processor
Secondary Subject demographics Subject demographics will be retrieved from the participants' medical file or by asking them if the information is not available. The 11th revision of the International Statistical Classification of Diseases and Related Health Problems (ICD-11) classification will be used to code subjects' health conditions. One month preoperatively and six months post the activation of the speech processor
See also
  Status Clinical Trial Phase
Recruiting NCT04696835 - fNIRS in Pediatric Hearing Aids N/A
Completed NCT03662256 - Reducing Childhood Hearing Loss in Rural Alaska Through a Preschool Screening and Referral Process Using Mobile Health and Telemedicine N/A
Completed NCT04602780 - Evaluating the Revised WORQ in CI Users
Completed NCT03723161 - Evaluation of the Ponto Bone Anchored Hearing System in a Pediatric Atresia Population
Completed NCT05086809 - Investigation of an Updated Bone-anchored Sound Processor N/A
Active, not recruiting NCT03548779 - North Carolina Genomic Evaluation by Next-generation Exome Sequencing, 2 N/A
Completed NCT03428841 - Audiovisual Assessment After Dural Puncture During Epidural Placement in Obstetric Patients N/A
Completed NCT04559282 - Home Test of New Sound Processor N/A
Enrolling by invitation NCT03345654 - Individually-guided Hearing Aid Fitting
Completed NCT06016335 - MRI-based Synthetic CT Images of the Head and Neck N/A
Completed NCT05165121 - Comparison of Hearing Aid Fitting Outcomes Between Self-fit and Professional Fit for MDHearing Smart Hearing Aids N/A
Recruiting NCT05533840 - Establishment and Application of a New Imaging System for Otology Based on Ultra-high Resolution CT
Terminated NCT02294812 - Effects of Cognitive Training on Speech Perception N/A
Completed NCT04622059 - AUditive Direct In-utero Observation (AUDIO): Prenatal Testing of Congenital Hypoacusis N/A
Recruiting NCT02558478 - Identification of New Genes Implicated in Rare Neurosensory Diseases by Whole Exome Sequencing N/A
Withdrawn NCT02740322 - Validating the Hum Test N/A
Completed NCT01963104 - Community-Based Kiosks for Hearing Screening and Education N/A
Completed NCT01892007 - Evaluation of Cogmed Working Memory Training for Adult Hearing Aid Users N/A
Completed NCT01857661 - The Influence of the Sound Generator Combined With Conventional Amplification for Tinnitus Control: Blind Randomized Clinical Trial N/A
Withdrawn NCT01223638 - The Prevalence of Hearing Loss Among Children With Congenital Hypothyroidism N/A