Hearing Loss Clinical Trial
Official title:
Randomized Controlled Trial Evaluating the Impact of Noise Exposure in Otolaryngology Floor Among Head and Neck Cancer Patients
A sound dosimeter will be used to measure noise level to which a population of head and neck patients on the otolaryngology ward are exposed to. The device is the EXTECH 407764 type II sound level meter (IEC 651 RS232). The device will be configured to OSHA and ISO standards, and calibration confirmed in a sound booth with a sound level calibrator. The dosimeter captures A-weighted sound levels between 30 and 130 dB. Specifically, participants included in the study will be head and neck cancer patients on the otolaryngology floor at VG site. Measurements will be taken three times a day at random intervals. Each measurement will be taken in a similar manner. The dosimeter will be placed on the head side of the bed at the level of patient's ear one inch away from the ear and kept there for ten seconds to get a representative level. The overall measurements will be averaged (Leq) for statistical analysis. Investigators will randomly select 50% of the patients and give them protective ear plugs to be used while the participants are inpatients, and the other 50% will not provide them with ear plugs (like what is being done now). Investigators will obtain a baseline hearing test prior to admission and 7 days after admission and then a repeat hearing test at 3 weeks after discharge. The goal is to establish if there is a temporary or a permanent threshold shift.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04696835 -
fNIRS in Pediatric Hearing Aids
|
N/A | |
Completed |
NCT03662256 -
Reducing Childhood Hearing Loss in Rural Alaska Through a Preschool Screening and Referral Process Using Mobile Health and Telemedicine
|
N/A | |
Completed |
NCT04602780 -
Evaluating the Revised WORQ in CI Users
|
||
Completed |
NCT03723161 -
Evaluation of the Ponto Bone Anchored Hearing System in a Pediatric Atresia Population
|
||
Completed |
NCT05086809 -
Investigation of an Updated Bone-anchored Sound Processor
|
N/A | |
Active, not recruiting |
NCT03548779 -
North Carolina Genomic Evaluation by Next-generation Exome Sequencing, 2
|
N/A | |
Completed |
NCT03428841 -
Audiovisual Assessment After Dural Puncture During Epidural Placement in Obstetric Patients
|
N/A | |
Completed |
NCT04559282 -
Home Test of New Sound Processor
|
N/A | |
Enrolling by invitation |
NCT03345654 -
Individually-guided Hearing Aid Fitting
|
||
Completed |
NCT06016335 -
MRI-based Synthetic CT Images of the Head and Neck
|
N/A | |
Completed |
NCT05165121 -
Comparison of Hearing Aid Fitting Outcomes Between Self-fit and Professional Fit for MDHearing Smart Hearing Aids
|
N/A | |
Recruiting |
NCT05533840 -
Establishment and Application of a New Imaging System for Otology Based on Ultra-high Resolution CT
|
||
Terminated |
NCT02294812 -
Effects of Cognitive Training on Speech Perception
|
N/A | |
Completed |
NCT04622059 -
AUditive Direct In-utero Observation (AUDIO): Prenatal Testing of Congenital Hypoacusis
|
N/A | |
Recruiting |
NCT02558478 -
Identification of New Genes Implicated in Rare Neurosensory Diseases by Whole Exome Sequencing
|
N/A | |
Withdrawn |
NCT02740322 -
Validating the Hum Test
|
N/A | |
Completed |
NCT01963104 -
Community-Based Kiosks for Hearing Screening and Education
|
N/A | |
Completed |
NCT01892007 -
Evaluation of Cogmed Working Memory Training for Adult Hearing Aid Users
|
N/A | |
Completed |
NCT01857661 -
The Influence of the Sound Generator Combined With Conventional Amplification for Tinnitus Control: Blind Randomized Clinical Trial
|
N/A | |
Withdrawn |
NCT01223638 -
The Prevalence of Hearing Loss Among Children With Congenital Hypothyroidism
|
N/A |