Clinical Trial Summary

The accurate assessment of auditory status is critical for planning treatment for Veterans with hearing loss to include medical and audiological management. Current physiologic tests of auditory function in the standard clinical audiological test battery for Veterans have limited sensitivity in detecting some middle-ear disorders, and do not include a direct test of cochlear function. Recent studies have shown promise for new wide-bandwidth (WB) tests of absorbance for improved sensitivity in the assessment of middle-ear function including acoustic reflex testing. The addition of WB tests of cochlear function included in the WB test battery provides an opportunity to improve audiological diagnosis of a range of hearing disorders in Veterans. The automation provided by the WB test battery could provide additional benefits in reducing the duration of the evaluation, leaving more time for evaluation of test findings and counseling. Results from this study may lead to the improvement of audiological care for Veterans with hearing loss.


Clinical Trial Description

The goal of this research is to evaluate a comprehensive test battery of new wide-bandwidth, i.e., wideband (WB), acoustical tests of auditory function in the differential diagnosis of middle ear, cochlear and neural pathologies in a population of Veterans. WB tests refer to ear canal tests using sound responses measured from 0.2 kilohertz (kHz) to frequencies as high as 8 kHz, a bandwidth that is critical for speech perception. There will be tests in the battery for middle-ear assessment using power absorption, cochlear assessment using otoacoustic emissions (OAEs) and the acoustic stapedius reflex (ASR) using middle ear power absorption. Results will be compared with a standard single-frequency clinical immittance test battery routinely used in the assessment of auditory function in Veterans. Aim 1 seeks to evaluate the accuracy of the WB test battery in the differential diagnosis of middle-ear pathology and related conductive hearing loss by comparing the sensitivity and specificity of the WB battery to the traditional immittance battery for the following disorders common in Veterans: tympanic membrane perforation, serous otitis media, cholesteatoma, and otosclerosis. Aim 2 seeks to modify a WB ASR test to provide automatic detection of the ASR threshold for comparison with the traditional single-frequency ASR threshold. Aim 3 seeks to validate the use of Transient-evoked otoacoustic emission (TEOAE) and spontaneous otoacoustic emissions (SOAEs)tests in Veterans to assess cochlear status, and evaluate their test performance in classifying ears with normal hearing and sensorineural hearing loss. Finally, Aim 4 seeks to compare the diagnostic accuracy of the full WB test battery with the full single-frequency admittance test battery to detect any type of hearing loss including sensorineural, conductive and mixed. The hypothesis is that the WB test battery is more accurate than the traditional immittance test battery in identifying ears with normal auditory status and ears with a range of risks for auditory pathology. Methods: Subjects- Human subjects will be recruited for this study who have had a hearing evaluation from the VA Audiology Service at the Portland VA Medical Center and the H. Quillen VA Medical Center. These subjects will respond to flyers or be contacted from an IRB-approved human subject volunteer registry. Additional details regarding recruitment and selection criteria may be found in the next sections of the protocol. The investigators will recruit approximately equal numbers of subjects, with a total of 640. Data will be acquired at the two sites from a total of 190 adult subjects with normal hearing and 180 adult subjects with sensorineural hearing loss. These subjects will be recruited from three age groups: 20-39 years, 40-59 years and 60-79 years for age comparisons of normative middle-ear data. Data will also be acquired at both sites from 250 adult subjects with middle-ear disorders and/or conductive hearing loss from ages 20-89 years. Of this latter group, the investigators plan to enroll 50 subjects with tympanic membrane perforation, 50 subjects with serous otitis media, 50 subjects with cholesteatoma, 50 subjects with otosclerosis, and 50 subjects with unspecified middle-ear disorders. The investigators expect that approximately 20 subjects (from all groups, normal hearing, sensorineural hearing loss, and middle-ear disorders) will be lost as screen failures or will drop from the study, and thus, the investigators will recruit an additional 20 subjects to replace these. This brings the total planned number of subjects recruited for study to 640. Testing- All subjects will receive the same clinical and WB test battery. Each subject will be tested in one laboratory visit. Subjects will be enrolled in this study that upon otoscopic inspection of their ear canals, have no active drainage from the ears, and have ear canals free of cerumen (wax) impaction, bilaterally. Subjects who are found to have draining ears or cerumen impaction will be referred for treatment. These individuals may be enrolled in the study following successful treatment for their conditions. All subjects will have a standard pure-tone air- and bone-conduction audiogram while comfortably seated in a sound-treated booth. Standard insert earphones and a bone-conduction vibrator will be used to present the sound stimuli. Next, speech audiometry will be completed and the speech reception thresholds, uncomfortable loudness test for speech, and speech recognition scores will be obtained. Then the subjects will have a standard immittance test battery consisting of a tympanogram and acoustic reflex threshold testing. Stimuli will not exceed a level of 100 decibels hearing level (dB HL). Finally, the wideband test battery will be performed with adults seated comfortably in a sound-treated booth. A small probe with a soft rubber tip will be inserted in the subject's ear canal, and the subject will be asked to remain quiet while sounds are presented to an ear via sound sources within the probe. Responses will be measured using a miniature microphone within the probe. The tests in the wideband battery are similar to the clinical admittance battery and include ambient absorbance, absorbance tympanometry and acoustic reflex threshold. The otoacoustic emission testing is a separate measurement of inner ear function typically conducted in the clinic using different equipment. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02019888
Study type Observational
Source VA Office of Research and Development
Contact
Status Completed
Phase
Start date December 1, 2014
Completion date January 31, 2020

See also
  Status Clinical Trial Phase
Completed NCT04281953 - Impact on Quality of Life of Long-term Ototoxicity in Cancer Survivors
Not yet recruiting NCT05973669 - MED-EL Remote Care Multi-Center Feasibility Study N/A
Completed NCT04601909 - FX-322 in Adults With Age-Related Sensorineural Hearing Loss Phase 1
Active, not recruiting NCT04479761 - Sensory Integration of Auditory and Visual Cues in Diverse Contexts N/A
Recruiting NCT05043207 - A Study Protocol for the Validation of UAud in a Clinical Setting. N/A
Recruiting NCT04066270 - Inventory of Radiological and Vestibular Function in Cochlear Implant Candidates
Recruiting NCT04070937 - Correlation of Radiological Lesions With Vestibular Function in Patients With Bilateral Vestibulopathy
Completed NCT03512951 - Subjective Evaluation of a Sound Processing Method for Hearing Aids on Auditory Distance Perception N/A
Completed NCT05855005 - Direct-to-Consumer Hearing Aids and Listening Effort N/A
Recruiting NCT05599165 - Speech Perception in Bimodal Hearing N/A
Completed NCT05101083 - Speech Intelligibility in Quiet and Noise for New vs. Legacy Hearing Aids N/A
Completed NCT05521308 - Investigating Hearing Aid Frequency Response Curves N/A
Completed NCT05072457 - Benefit of Assistive Listening Device for Lateralization N/A
Recruiting NCT05776459 - Efficacy and Safety of AC102 Compared to Steroids in Adults With Idiopathic Sudden Sensorineural Hearing Loss (ISSNHL) Phase 2
Completed NCT05086276 - FX-322 in Adults With Acquired Sensorineural Hearing Loss Phase 2
Recruiting NCT06058767 - Preschool Hearing Screening N/A
Completed NCT05180630 - Sound Quality Comparisons With Different Hearing Aid Couplings and Venting Systems N/A
Completed NCT03613909 - Acceptance of the CP950 Sound Processor N/A
Active, not recruiting NCT03352154 - Long Latency Auditory Evoked Potentials (P300) Outcomes in Patients With Unilateral Cochlear Implants N/A
Completed NCT04629664 - FX-322 in Adults With Severe Sensorineural Hearing Loss Phase 1