The Microtable® Microstereotactic Frame and Drill Press and Associated Method for Cochlear Implantation consists of a patient-customized microstereotactic frame which targets the cochlea. The intended use of the device in this early feasibility study is to surgically access the cochlea, allowing placement of an intra-cochlear electrode array for cochlear implantation, thereby providing a less invasive surgical option than currently performed. Compared to traditional cochlear implantation (CI) surgery, the investigators hypothesize that the minimally invasive, image-guided approach may offer the following benefits: (1) shorter procedure time including shorter general anesthesia time, (2) less tissue removal potentially eliminating post-operative mastoid bone depression, decreased post-operative patient discomfort, and quicker wound healing, (3) better chance of preservation of taste secondary to preservation of the chorda tympani nerve, and (4) standardization of electrode placement potentially allowing more consistent placement within the scala tympani sub-compartment of the cochlea which has been shown to be associated with improved post-operative audiological performance. This early feasibility study will focus on the advantages of the new technology to the patient. Advantages to the healthcare delivery system will be examined during the pivotal study phase.


Clinical Trial Description

The Microtable® Microstereotactic Frame and Drill Press and Associated Method for Cochlear Implantation consists of a patient-customized microstereotactic frame which targets the cochlea. The intended use of the device in this early feasibility study is to surgically access the cochlea, allowing placement of an intra-cochlear electrode array for cochlear implantation, thereby providing a less invasive surgical option than currently performed. Compared to traditional cochlear implantation (CI) surgery, the investigators hypothesize that the minimally invasive, image-guided approach may offer the following benefits: (1) shorter procedure time including shorter general anesthesia time, (2) less tissue removal potentially eliminating post-operative mastoid bone depression, decreased post-operative patient discomfort, and quicker wound healing, (3) better chance of preservation of taste secondary to preservation of the chorda tympani nerve, and (4) standardization of electrode placement potentially allowing more consistent placement within the scala tympani sub-compartment of the cochlea which has been shown to be associated with improved post-operative audiological performance. This early feasibility study will focus on the advantages of the new technology to the patient. Advantages to the healthcare delivery system will be examined during the pivotal study phase. The investigators propose this early feasibility study to determine if minimally invasive image-guided drilling to surgically access the cochlea for CI can be successfully performed. The study will involve only unilateral CI. The decision of unilateral vs. bilateral implantation is made clinically and before the patient may elect to enroll in this study. Bilateral implantation can take place either simultaneously or sequentially, with the decision made by the clinician as part of standard care. If a participant is scheduled for routine bilateral CI, the traditional approach will be used on one side and the investigational approach on the other. Traditional surgery will be performed on the better-hearing ear, and the investigational technique will be performed on the poorer hearing ear. To minimize patient variability, the investigators will only be studying lateral wall electrodes, the Cochlear slim straight electrode and MED-EL electrodes. The investigators plan to enroll 12 cochlear implant patients in two groups. Group 1 will consist of patients implanted under direct visualization afforded by lifting a tympanomeatal flap, and Group 2 will consist of patients implanted with visualization afforded by passing an endoscope across the eardrum via a myringotomy. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03101917
Study type Interventional
Source Medical University of South Carolina
Contact Robert F. Labadie, MD, PhD
Phone 843-792-7161
Email labadie@musc.edu
Status Not yet recruiting
Phase N/A
Start date July 1, 2024
Completion date July 31, 2024

See also
  Status Clinical Trial Phase
Completed NCT04222296 - Bimodal, CROS and Severe Profound Hearing Loss Study N/A
Recruiting NCT04130113 - Expanded Indications in the MED-EL Pediatric Cochlear Implant Population N/A
Completed NCT05052944 - Single-sided Deafness and Cochlear Implantation
Terminated NCT05586555 - A Monocentric Study Evaluating Pupillometry as an Objective Measurement for CI Fittings N/A
Not yet recruiting NCT06424262 - Performance and Hearing-related Outcomes in Adults Implanted With the CI622D Dexamethasone-eluting Cochlear Implant Compared to Those Implanted With a Standard Cochlear Implant (CI622) N/A
Recruiting NCT05474963 - Sudden Sensorineural Hearing Loss in Wonju Severance Christian Hospital
Recruiting NCT03848338 - Electrocochleography Function for Monitoring Residual Hearing N/A
Not yet recruiting NCT06218966 - Usability of the Intracochlear Catheter INCAT - a Feasibility Study N/A
Completed NCT06326866 - Otoacoustic Emissions in Different Blood Types
Completed NCT02941627 - The Neuro Zti Cochlear Implant System Efficacy and Safety in Adults N/A
Completed NCT05237180 - Evaluation of the Effect of a Spatial Localization Training Program on Auditory Comprehension N/A
Completed NCT04010721 - Effects of Pulses on Loudness N/A
Recruiting NCT04919928 - Benefits From Bimodal Fittings With Cochlear Implant and Hearing Aid vs Bilateral Hearing Aids N/A
Recruiting NCT04724265 - Cytomegalovirus (CMV) Perilymphatic Fluid N/A
Completed NCT02948790 - Auditory Nerve Monitoring Using Intra-cochlear Stimulation in Subjects With Acoustic Neuroma N/A
Withdrawn NCT04357704 - Improved Speech Recognition Performance in Noise by Encoding Binaural Spatial Cues to the Cochlea Implant User N/A