Theoretically, there is a correlation between the PWV and the value of the BP, mediated by the distensibility of the segment of artery where the measurements take place. The hypothesis is therefore that the measurement of the PWV through a multisite medical device for detecting the pulse wave by photoplethysmography makes it possible to deduce the value of the BP.


Clinical Trial Description

The aim is to test on healthy volunteers a prototype of a non-invasive, non-CE marked medical device (VOP1k ) for the continuous monitoring of pulse wave velocity (PWV) and to study the relationship between this value and the blood pressure (BP). Indeed, the monitoring of hemodynamic parameters constitutes an essential element of the basal monitoring of patients. Among these parameters, the most used and the most routine is the measurement of BP. This measurement makes it possible in particular to detect the presence or absence of arterial hypertension (HTA), which is a major cause of premature mortality, of high prevalence within the population, involving high medical costs. Contrary to what one might think, the practice of measuring BP is not completely satisfactory, each of the techniques used having characteristics likely to lead to errors of judgment. Oscillometric and auscultatory techniques give discontinuous measurements, expose to the white coat effect when they are performed by a caregiver. Arterial occlusion by external back pressure, which is the basis of these measurement techniques, causes erroneous results and discomfort during repetitive measurements. The use of commercial semi-automatic BP monitors is fraught with validation problems. The necessary confirmation of the diagnosis of hypertension, which is based on ambulatory measurements for 24 hours using these devices, is therefore questionable. The diagnosis of the importance of arterial damage at the base of hypertension could be carried by measurements of the PWV which reflects the stiffness of the arteries. However, this diagnostic means is not currently based on a technology that can be used routinely. Means of measuring BP and arterial stiffness by invasive techniques, which are themselves subject to the risk of poor signal transmission, cannot be used outside the hospital, due to the associated risks. Non-invasive continuous measurement by the volume clamp technique, although devoid of the risks of arterial catheterization, is not available outside specialized hospital departments, and also has the disadvantage of relying on the use of external counter pressure.The technique of measurement by (photoplethysmography (PPG)), i.e. the use of an optical sensor, placed in a non-invasive way on the path of a shallow artery, makes it possible to detect the passage of the pulse wave . The combined use of several sensors located at a distance from each other on the path of the same artery, thus makes it possible to determine the velocity of the pulse wave. This technique can potentially measure over short distances, which limits the sources of error, and allows continuous measurement without discomfort. Moreover, it is compatible with low-cost integration. Indeed, acquisition technologies based on microelectronics are widely developed and mature since their massive use in smartphones. The measurement of PWV makes it possible to quantify arterial stiffness, which is a direct risk factor for morbidity and mortality associated with cardiovascular pathologies. The additional interest of this measurement, in addition to the fact of its non-invasiveness, comes from the fact that there is a correlation between the PWV and the BP, and therefore that the measurement of the PWV can make it possible to obtain a measurement of the BP. It should be noted that one aspect of the aspects of blood pressure measurement consists of being able to measure the central blood pressure, that is to say that which reigns in the aorta. However, most of the measurement techniques used routinely only measure the peripheral arterial pressure, which makes it necessary to use transfer functions to know the central pressure, or to ignore the differences in central pressure/peripheral pressure behavior. The technology proposed for the measurement makes it possible to consider overcoming this problem by placing, in one of the versions, a sensor at the carotid level, which is the arterial segment that best reflects the central pressure, unlike the humeral, femoral or radial segments. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05393401
Study type Interventional
Source University Hospital, Grenoble
Contact Daniel ANGLADE, MD, PhD
Phone 04 38 78 17 46
Email danglade@chu-grenoble.fr
Status Recruiting
Phase N/A
Start date October 25, 2022
Completion date June 1, 2024

See also
  Status Clinical Trial Phase
Completed NCT05001152 - Taste Assessment of Ozanimod Phase 1
Completed NCT05029518 - 3-Way Crossover Study to Compare the PK (Pharmokinetics) and to Evaluate the Effect of Food on the Bioavailability Phase 1
Completed NCT04493255 - A Study to Determine the Metabolism and Elimination of [14C]E7090 in Healthy Male Participants Phase 1
Completed NCT03457649 - IV Dose Study to Assess the Safety, Tolerability, PK, PD and Immunogenicity of ARGX-113 in Healthy Volunteers Phase 1
Completed NCT00995891 - Collection of Blood, Bone Marrow, and Buccal Mucosa Samples From Healthy Volunteers for Center for Human Immunology, Autoimmunity, and Inflammatory Diseases (CHI) Laboratory Research Studies
Completed NCT05043766 - Evaluation of Oral PF614 Relative to OxyContin Phase 1
Completed NCT05050318 - Annual Study for Collection of Serum Samples in Children and Older Adults Receiving the 2021-2022 Formulations of Fluzone Quadrivalent Vaccine and Fluzone High-Dose Quadrivalent Vaccine, Respectively Phase 4
Completed NCT04466748 - A Multiple Ascending Dose Pharmacology Study of Anaprazole in Healthy Chinese Subjects Phase 1
Completed NCT00746733 - Vyvanse and Adderall XR Given Alone and in Combination With Prilosec OTC Phase 1
Recruiting NCT05929651 - Study of Immunogenicity and Safety of MenQuadfi® as a Booster Vaccine in Toddlers 12 to 23 Months, Regardless of the Quadrivalent Meningococcal Conjugate Vaccine Used for Priming in Infancy Phase 4
Completed NCT05954039 - Evaluation of the Efficacy of a Dietary Supplement on Hair Loss and Hair Aspect N/A
Completed NCT05045716 - A Study of Subcutaneous Lecanemab in Healthy Participants Phase 1
Active, not recruiting NCT02747927 - Efficacy, Safety and Immunogenicity of Takeda's Tetravalent Dengue Vaccine (TDV) in Healthy Children Phase 3
Completed NCT05533801 - A Study to Demonstrate the Bioequivalence of Lecanemab Supplied in Vials and a Single-Use Auto-Injector (AI) in Healthy Participants Phase 1
Not yet recruiting NCT03931369 - Adaptation of Thirst to a Single Administration of Tolvaptan (TOLVATHIRST) Phase 2
Completed NCT03279146 - A Single Dose Study Evaluating PK of TXL Oral Formulations in Healthy Subjects Phase 1
Completed NCT06027437 - A Study to Assess the Relative Biological Availability and the Effect of Food on the Drug Levels of Danicamtiv in Healthy Adult Participants Phase 1
Recruiting NCT05619874 - Effects of Two Virtual HIFCT Programs in Adults With Abdominal Obesity N/A
Completed NCT05553418 - Investigational On-body Injector Clinical Study N/A
Completed NCT04092712 - Study Evaluating Pharmacokinetics and Mass Balance of [14C]-CTP-543 in Healthy Adult Male Volunteers Phase 1