Clinical Trials Logo

Clinical Trial Summary

The use of ultrasound is becoming widespread to guide the placement of arterial lines for both vascular access and regional anesthesia in the field of anesthesia. Arterial line placement can be challenging, especially in the pediatric population. Frequently multiple attempts are required with relatively high failure rates. This can result in excessive needle punctures and extended OR times. A few studies have looked at the use of ultrasound to decrease OR time and increase success rates both in adult and pediatric populations. These studies compared the traditional palpation method with either short axis or long axis views of the vessel using ultrasound guidance. No study to date has compared short axis and long axis views for arterial line placement in either the pediatric or adult population. Our study compares success rates and OR times when long and short axis methods of arterial line insertion are employed in the pediatric population.


Clinical Trial Description

An Arterial line is an intraoperative monitor that is frequently placed in the pediatric population. Due to their smaller anatomy and more compliant skin, arterial lines can be more difficult to insert in the pediatric population than in adults. Additionally, lower perfusion pressure and larger subcutaneous adipose tissue can make pulse palpation more difficult. Ultrasound is a modality that can directly image the radial, ulnar, or brachial artery. Along with 2D ultrasound, doppler ultrasound can be utilized to confirm that an artery is not a vein. Once the vessel is identified, the vessel can be viewed in either the long or short access. The ultrasound beam is only 1 millimeter thick so a practitioner must stabilize the probe to view the vessel, especially in the long axis view. Once the artery is viewed in long axis, the needle can be directly visualized all the way into the vessel. Visualization of a guidewire or catheter in the vessel can confirm proper arterial access. In a short access ultrasound view, it is possible to see tissue movement and sometimes a hyperechoic (bright) dot which represents the needle. Tissue movement can help confirm the needle is immediately above the artery at all times. The advantage of the short axis view is that less precision is needed to hold and position the transducer than with the long axis view. The disadvantage of the short axis view is that the operator cannot see the tip of the angiocatheter as it enters the vessel. As a result, the proximal portion of the angiocatheter can be above the artery but the distal tip could be to the side of the artery. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00859846
Study type Interventional
Source University of Oklahoma
Contact
Status Completed
Phase N/A
Start date March 17, 2009
Completion date September 25, 2018

See also
  Status Clinical Trial Phase
Completed NCT04577430 - Effects of Dexmedetomidine on Cardiac Electrophysiology in Patients Under General Anesthesia During Perioperative Period N/A
Completed NCT03708692 - Menstrual Cycle Phases on Recovery and Cognitive Function
Recruiting NCT03422315 - Population Pharmacokinetics and Clinical Individual Dosage Regimen of Propofoll Injection N/A
Completed NCT02771067 - The Utility of Pulse Pressure Variation to Predict the Fluid Responsiveness During Pneumoperitoneum and Reverse-Trendelenburg Position N/A
Completed NCT05063461 - Evaluation of the Analgesia Nociception Index With Varying Remifentanil Concentrations Under Sevoflurane N/A
Completed NCT03294226 - Comparison of AuraGain With I-gel for Pediatric Patients N/A
Not yet recruiting NCT03643029 - The Accuracy of the Performance and Placement Test for Predicting Supraglottic Airway Device (SAD) Position in the Hypopharynx as Confirmed With Video Laryngoscopy N/A
Completed NCT01945411 - Assessment of Facial Measurements, the Length of Mouth Corner-mandible Angle and Incisors-mandible Angle, for Determining the Proper Sizes of Oropharyngeal Airway N/A
Not yet recruiting NCT01678066 - A Prospective Study to Bilaterally Compare a Non-Invasive Cardiac Output Monitor N/A
Completed NCT01705743 - Minimum Alveolar Concentration of Sevoflurane With Nitrous Oxide Inducing Isoelectric EEG Phase 4
Completed NCT00972491 - The Optimal Time to Put Laryngeal Mask Airway in the Mouth Under General Anesthesia N/A
Completed NCT01096212 - Efficacy and Safety of Sevofran in Patients Scheduled for Elective Surgery Under General Anesthesia Phase 4
Completed NCT00741507 - Unhealthy Alcohol Drinking and Anesthetic Requirement in Women N/A
Completed NCT00532402 - Continuous and Discontinuous Determination of Propofol Concentration in Breathing Gas N/A
Completed NCT00599066 - Intraoperative M-Entropy Measurements N/A
Completed NCT00468494 - Can Blood Glucose Levels During the Perioperative Period Identify a Population at Risk for Hyperglycemia? N/A
Recruiting NCT00492453 - Spinal Versus General Anesthesia for Laparoscopic Cholecystectomy N/A
Recruiting NCT03745079 - Correlation Between Core Temperature and Skin Temperature Measured by 3M SpotOn
Completed NCT04094376 - Comparison of Morning Operation and Evening Operation on Postoperative Sleep Quality and Pain Under General Anesthesia N/A
Enrolling by invitation NCT03672734 - Volume and pH of Gastric Contents in Patients Undergoing Gynecologic Laparoscopic Surgery During Emergence From General Anesthesia