Clinical Trials Logo

Clinical Trial Details — Status: Terminated

Administrative data

NCT number NCT01825564
Other study ID # EZNG-SLU-450126, 22201
Secondary ID
Status Terminated
Phase N/A
First received February 6, 2013
Last updated January 20, 2017
Start date March 14, 2013
Est. completion date May 25, 2016

Study information

Verified date January 2017
Source St. Louis University
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

Replacing a G tube and placing feeding tubes is standard in the Emergency Department (ED) and ICU, respectively. However placement requires a chest or abdominal x-ray to confirm correct position. The investigators are testing the accuracy of the FDA approved devices RightSpot pH Indicator & RightLevel pH Detector in determining correct position based upon pH which will then be correlated with the standard of care x-ray.


Description:

Feeding tube placement is a common procedure that occurs in most ICU healthcare settings. In addition, replacement of G-tubes is a common practice in most ED settings throughout the US. Various practices have been used to confirm its placement, including the usage of litmus paper (acid versus base only), pH level indicators (precise measurement), auscultation, bubbling method, aspirate appearance, chest radiography (CXR) and gastrografin .

Review of data in numerous studies has revealed that many of these techniques may not provide fully accurate results, possibly leading to the potential for patient injuries, and even fatal complications. Auscultation, bubbling method, and aspirate appearance have been demonstrated to provide findings that can be misinterpreted and cause false assurance of correct placement. Several deaths and serious injuries have been attributed to the use of litmus paper in verification of feeding tube placement and subsequent utilization of the tube as well as G-tube replacement. Consequently, litmus paper is no longer considered to be a safe and effective confirmatory test for feeding tube placement or G-tube replacement.

Currently, the gold standard for verification of feeding tube placement is CXR or abdominal x-ray and G-tube replacement in an acute care setting is abdominal x-ray with gastrografin. This method is time-consuming, costly, and results in an increase in patient exposure to radiation. In addition for a patient who resides outside of the hospital setting at the time of needed G-tube replacement there is additional costs of transport to and from the ED. An alternative to CXR is measurement of gastric content pH level. This is a confirmed and valid tool for nasogastric/orogastric (NG/OG) verification and a recognized replacement of the litmus paper test.A pH level of 4.5 or less has been validated to indicate presence of gastric contents. A drawback to the use of typical pH indicators alone is that they require fluid aspirate to be placed manually onto the indicator surface. This increases the risk of exposure to bodily fluids for medical personnel. Thus, the ideal device to determine accurate feeding tube placement and G-tube replacement is one that will precisely measure the acid (pH) level of aspirate and significantly reduce the risk of bodily fluid exposure.

The RightSpot pH Indicator & RightLevel pH Detector are devices which purport to meet both of these criteria. Both can provide an accurate pH level. The pH paper is encased in a protective exterior that can be attached directly to a syringe, thus, decreasing the likelihood of accidental exposure.

This study will evaluate the use of this novel device to accurately verify feeding tube placement in an ICU care setting and G-tube replacement (of foley catheter) by measuring the pH and comparing this with gastrografin radiographic confirmation.

The G-tube (or foley catheter) will be placed by the treating physician, resident, mid-level provider or nurse as per policy and standard of care in the ICU or Emergency Department. Prior to x-ray confirmation of placement with gastrografin, the RightBio Metrics device will be placed on the tube as per manufacturer's instructions and stomach contents aspirated. The reading of the pH indicator and time it took to measure the pH will be recorded. The device will then be removed. Tube placement verification by x-ray will be done as per hospital protocol. The time of radiology reading of the x-ray will be documented.

Procedures for feeding tube are similar, however two pH measurements will be obtained. The first measurement will be obtained with RightSpot pH Indicator at the time the tube is inserted into the stomach to measure gastric pH, and the second pH measurement will be obtained one hour later with RightLevel pH Detector to assess whether or not a pH change has occurred that suggests the tube has migrated into the small bowel. Radiographic confirmation will also be obtained at that time as it is the standard of care for feeding tube placements at SLU Hospital.

Relevant aspects of subject's prior history will be recorded on a standardized data collection form (DCF). These include:

- Demographics

- Surgical history - when the G-tube was placed

- Current medications

- Any previous gastric bypass surgery or other GI surgery

- Use of acid-reducing medications in the past week (e.g. antacids, proton pump inhibitors, histamine antagonists)

- Relevant medical history (e.g. gastric ulcer, achlorhydria)

- Cost related information such as ambulance cost to and from ED, cost of x-ray for G-tube (or foley) replacement, cost of radiographic interpretation

As this is a minimal risk device and the main endpoint is whether or not the device could determine placement of a feeding tube or G-tube, patients will not be followed beyond 24 hours.


Recruitment information / eligibility

Status Terminated
Enrollment 11
Est. completion date May 25, 2016
Est. primary completion date May 25, 2016
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

- Age older than 18

- Requirement for placement of a feeding tube or a G-tube replacement

- Patient or proxy able to provide informed consent

- English proficiency of person providing informed consent

Exclusion Criteria:

- Patients that are younger than the age of 18

- Inability to obtain consent

- Grossly bloody aspirate

- Pregnancy

Study Design


Related Conditions & MeSH terms


Locations

Country Name City State
United States Saint Louis University Hospital St. Louis Missouri

Sponsors (1)

Lead Sponsor Collaborator
St. Louis University

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary pH measurement of gastric or duodenal secretions The pH measurement obtained will be used to determine correct placement of the gastric or feeding tube as compared to the gold standard method of X-ray following gastrograffin administration Within 24 hours of tube insertion prior to the initiation of tube feeding
Secondary Costs associated with G-tube reinsertion in the Emergency Department A collection of all costs related to the Emergency Department visit related to the replacement of the G-tube Within 2 weeks of Discharge from the Emergency Department
See also
  Status Clinical Trial Phase
Recruiting NCT03959878 - Feasibility of a Constant Pressure Skin Disk (CPSD) in Enteral Tubes. N/A
Active, not recruiting NCT04566367 - Blue Laser Imaging (BLI) for Detection of Secondary Head and Neck Cancer N/A
Recruiting NCT04110613 - RCT: Early Feeding After PEG Placement N/A
Completed NCT03319576 - Early Feeding Following Percutaneous Gastrostomy Tube Placement N/A
Completed NCT03575754 - A Single-center, Feasibility Study to Evaluate the Use and Safety of the Percutaneous Ultrasound Gastrostomy Technique N/A
Enrolling by invitation NCT06129877 - CHAMP App Feeding Difficulties Repository
Completed NCT04183296 - The Effect of Total Intravenous Anesthesia and Volatile Anesthesia on Shedding of the Endothelial Glycocalyx in Patients Undergoing Laparoscopic or Robotic Assisted Gastrectomy N/A
Recruiting NCT02909205 - a Care Protocol for Caregivers and Parents of Children Recently Gastrostomised N/A
Recruiting NCT04636099 - Gastrointestinal Surgery Study Group 2001 N/A
Recruiting NCT06464978 - Stapler Reinforcement Patches Compared to Standard Staplers in Gastrojejunostomy N/A
Not yet recruiting NCT05955534 - Concomitant Bedside Percutaneous Tracheostomy and Ultrasound Gastrostomy N/A
Completed NCT02869321 - Analgesic Efficacy of Transmucosal Fentanyl for Breakthrough Pain Caused by Interventional Gastrostomy Phase 4
Recruiting NCT05205343 - Trans-Pacific Multicenter Collaborative Study of Minimally Invasive Proximal Versus Total Gastrectomy for Proximal Gastric and Gastroesophageal Junction Cancers
Recruiting NCT03874871 - Function Preserving Gastrectomy for T1/2 Gastric Cancer Patients
Completed NCT03252509 - Outpatient Percutaneous Radiologic Gastrostomy in Patients With Head and Neck Tumors N/A
Completed NCT04804631 - Tube Feeding in Children Having a Bone Marrow Transplant
Completed NCT04919577 - Predictive Factors for Roux Stasis Syndrome
Completed NCT04151030 - Endoscopic Direct-PEG Placement in Patients Unable to Undergo Pull-PEG Procedure N/A
Not yet recruiting NCT06431048 - No DIET Trial: Dogmatic Interruption of Enteral nuTrition N/A
Completed NCT05994079 - Effect Of High-Intensity Focused Ultrasound On Abdominal Skin Laxity Post Sleeve Gastrectomy N/A