Percutaneous PFO closure has been established as a first-line therapy for preventing recurrent strokes in selected patients. The devices used for the specific purpose contain and release nickel, which is considered as the most allergen metal in nature. Skin patch tests are considered as gold-standard for documenting nickel allergy. While the allergic contact dermatitis induced by nickel is well described, literature is inadequate on explaining the effect of nickel release on the clinical manifestations of patients implanted with such devices. Our prospective, randomized, blinded trial will try to investigate the above by performing nickel skin patch tests to all patients, 14 days before and 90 days after the implantation. During follow-up, clinical manifestations and transthoracic echocardiographic findings will be evaluated and associated with patch skin tests.


Clinical Trial Description

Percutaneous PFO closure has been established as a first-line therapy for preventing recurrent strokes, after embolic stroke of unknown source (ESUS) and a patent foramen ovale. The PFO closure is achieved by the implantation of suitable devices, which occlude the shunt between the two atria and prevent the creation and detachment of thrombi. Until today, there are two devices approved by FDA for the specific purpose; Amplatzer PFO Occluder and Gore Cardioform Septal Occluder. Despite the architectonic differences between these devices, the main material of both is nitinol, an alloy of nickel and titanium. While titanium is an extremely rare allergen, nickel is considered as one of the most common allergens and the most frequent metal allergen in nature, with a prevalence about 20%. The main clinical expression of nickel hypersensitivity is allergic contact dermatitis, but cases with systemic allergic reaction have been described as well. It has been observed that nickel is released by the implanted devices and circulates through bloodstream, having the potential to cause systemic clinical picture. Device syndrome includes signs and symptoms (i.e. palpitations, dyspnea, chest pain, rash, etc.), which are appeared after the device placement and are associated with hypersensitivity reaction. The existing literature is considered as inadequate for explaining the effect of nickel release in the patients implanted with an occluder. Our trial will try to investigate the impact of device placement to nickel skin patch test results and the correlation with the clinical manifestations of patients. Considering that, skin patch tests for nickel and other allergens will be performed in all included patients, 14 days prior and 90 days after the procedure. The patients will be randomized to receive either Amplatzer or Gore device, with parallel assignment and randomization 1:1. During follow-up, clinical manifestations and transthoracic echocardiographic findings will be evaluated and associated with patch skin tests. The time frame of 90 days has been selected, due to the duration of device's endothelization and nickel release. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04713683
Study type Interventional
Source National and Kapodistrian University of Athens
Contact Anastasios Apostolos, MD, PhD
Phone 6980870458
Email anastasisapostolos@gmail.com
Status Recruiting
Phase N/A
Start date December 10, 2020
Completion date September 1, 2024

See also
  Status Clinical Trial Phase
Completed NCT00196040 - The Paradigm II Trial: PFX Closure System in Subjects With Cryptogenic Stroke, Transient Ischemic Attack, Migraine or Decompression Illness N/A
Recruiting NCT01934725 - Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome
Enrolling by invitation NCT03373929 - Stitch Closure of PFO and Septal Repair N/A
Completed NCT02432131 - Decompression Sickness in Divers With or Without Patent Foramen Ovale
Recruiting NCT04987008 - Risk of Ischaemic Stroke After Pulmonary Embolism in Patients With and Without Patent Foramen Ovale
Recruiting NCT04881578 - Atrial Fibrillation Before and After Patent Foramen Ovale Closure Study
Completed NCT02400892 - Patent Foramen Ovale and the Risk of Postoperative Delirium Following Elective Hip and Knee Arthroplasty Surgeries N/A
Recruiting NCT01385670 - InterSEPT: Inā€Tunnel SeptRx European PFO Trial N/A
Completed NCT02957201 - The Effect on EPCs by Successful Cardiac Occlusion Device Implantation N/A
Completed NCT00968032 - Procedural Success and Safety of the Nit-Occlud® Patent Foramen Ovale (PFO) Closure Device and Its Application System N/A
Recruiting NCT05558774 - Long-term Outcomes After Percutaneous Closure of PFO
Completed NCT02127294 - Effectiveness and Safety of Transcatheter Patent Foramen Ovale Closure for Migraine N/A
Recruiting NCT01149447 - Prospective Clinical Follow-up After the Percutaneous Closure of a Patent Foramen Ovale N/A
Enrolling by invitation NCT05025475 - Stitch Closure of PFO and Septal Repair (STITCH) N/A
Suspended NCT04339699 - NobleStitch EL STITCH Trial is a PFO Comparative Trial N/A
Withdrawn NCT03232450 - Patent Foramen Ovale (PFO) Closure at the Time of Endovascular Cardiac Electronic Device Implantation N/A