Clinical Trials Logo

Clinical Trial Summary

Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction.


Clinical Trial Description

Doppler ultrasound of the common carotid artery has begun to be used as a potential non-invasive tool for assessing hemodynamic status. Its non-invasive nature, ability to be applied independently of the patient's position, ease of application due to the superficial location of the carotid artery, and resistance to intrathoracic pressure changes are among its advantages. Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. Additionally, the velocity time integral (VTI) measuring blood flow through the carotid artery during systole, when multiplied by the cross-sectional area of the carotid artery, allows for the determination of flow within the carotid artery. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06087250
Study type Observational
Source Marmara University
Contact
Status Completed
Phase
Start date August 1, 2023
Completion date October 24, 2023

See also
  Status Clinical Trial Phase
Not yet recruiting NCT01941472 - Transcutaneous pO2, Transcutaneous pCO2 and Central Venous pO2 Variations to Predict Fluid Responsiveness N/A
Terminated NCT03208023 - RESIPI for Reducing Perioperative Major Adverse Cardiac Events N/A
Completed NCT03713008 - Assessment Of Carotid Flow During General Anesthesia N/A
Completed NCT02277353 - Evaluation of SVV From NICOM as a Predictor of Fluid Responsiveness in Prone Position During Spine Surgery N/A
Not yet recruiting NCT04092036 - Optic Nerve Sheath Diameter in Prediction of Fluid Responsiveness
Completed NCT04060069 - Pneumoperitoneum and Trendelenburg Position on Fluid Responsiveness
Recruiting NCT05153837 - Effect of Oral Water in Healthy Volunteers on Cardiac Output, Regional Flow and Microcirculation in Healthy Volunteers N/A
Not yet recruiting NCT06143111 - A Comparison of Thoracic Electrical Bioimpedance and FloTrac/Vigileo N/A
Not yet recruiting NCT05601622 - RPVI for Fluid Responsiveness in Children N/A
Completed NCT04889807 - Study of End Tidal Carbon Dioxide (EtCO2) Variation After an End- Expiratory Occlusion Test as a Predictive Criteria of Fluid Responsiveness in Mechanically Ventilated Patients
Recruiting NCT04186416 - Effectiveness of the Pressure Recording Analytical Method in Predicting Fluid Responsiveness in Pediatric Critical Care Patients
Completed NCT01996956 - Prediction of Fluid Responsiveness by NICOM (Non-invasive Cardiac Output Monitoring) in Children With Congenital Heart Disease After Cardiac Surgery N/A
Enrolling by invitation NCT04388995 - SVV and PPV Predict Fluid Responsiveness in Mechanically Ventilated Elderly Patients Under General Anesthesia N/A
Not yet recruiting NCT04574011 - Fluid Responsiveness in Spontaneously Ventilating Patient N/A
Completed NCT01821742 - Echocardiography in Kids Intensive Care Decision Support
Completed NCT04802668 - Factors Influencing of Pulse Pressure Variation (PPV)
Not yet recruiting NCT06254456 - Fluid Responsiveness in Prone Patients N/A
Completed NCT02789124 - Diagnostic Value of Passive Leg Raise Induced Changes in Carotid Artery Flow Time to Predict Fluid Responsiveness in Critically Ill Patients N/A
Completed NCT02040948 - Accuracy of Pulse Pressure Variation and of Pleth Variability Index to Predict the Response to a Fluid Challenge N/A
Withdrawn NCT01898975 - A Gray Zone Approach to Stroke Volume Variation Derived From NICOM N/A