Fluid Responsiveness Clinical Trial
Official title:
Reliability of Carotid Artery Corrected Flow Time Predicting Fluid Responsiveness in Geriatric Patients.
Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction.
Doppler ultrasound of the common carotid artery has begun to be used as a potential non-invasive tool for assessing hemodynamic status. Its non-invasive nature, ability to be applied independently of the patient's position, ease of application due to the superficial location of the carotid artery, and resistance to intrathoracic pressure changes are among its advantages. Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. Additionally, the velocity time integral (VTI) measuring blood flow through the carotid artery during systole, when multiplied by the cross-sectional area of the carotid artery, allows for the determination of flow within the carotid artery. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT01941472 -
Transcutaneous pO2, Transcutaneous pCO2 and Central Venous pO2 Variations to Predict Fluid Responsiveness
|
N/A | |
Terminated |
NCT03208023 -
RESIPI for Reducing Perioperative Major Adverse Cardiac Events
|
N/A | |
Completed |
NCT03713008 -
Assessment Of Carotid Flow During General Anesthesia
|
N/A | |
Completed |
NCT02277353 -
Evaluation of SVV From NICOM as a Predictor of Fluid Responsiveness in Prone Position During Spine Surgery
|
N/A | |
Not yet recruiting |
NCT04092036 -
Optic Nerve Sheath Diameter in Prediction of Fluid Responsiveness
|
||
Completed |
NCT04060069 -
Pneumoperitoneum and Trendelenburg Position on Fluid Responsiveness
|
||
Recruiting |
NCT05153837 -
Effect of Oral Water in Healthy Volunteers on Cardiac Output, Regional Flow and Microcirculation in Healthy Volunteers
|
N/A | |
Not yet recruiting |
NCT06143111 -
A Comparison of Thoracic Electrical Bioimpedance and FloTrac/Vigileo
|
N/A | |
Not yet recruiting |
NCT05601622 -
RPVI for Fluid Responsiveness in Children
|
N/A | |
Completed |
NCT04889807 -
Study of End Tidal Carbon Dioxide (EtCO2) Variation After an End- Expiratory Occlusion Test as a Predictive Criteria of Fluid Responsiveness in Mechanically Ventilated Patients
|
||
Recruiting |
NCT04186416 -
Effectiveness of the Pressure Recording Analytical Method in Predicting Fluid Responsiveness in Pediatric Critical Care Patients
|
||
Completed |
NCT01996956 -
Prediction of Fluid Responsiveness by NICOM (Non-invasive Cardiac Output Monitoring) in Children With Congenital Heart Disease After Cardiac Surgery
|
N/A | |
Enrolling by invitation |
NCT04388995 -
SVV and PPV Predict Fluid Responsiveness in Mechanically Ventilated Elderly Patients Under General Anesthesia
|
N/A | |
Not yet recruiting |
NCT04574011 -
Fluid Responsiveness in Spontaneously Ventilating Patient
|
N/A | |
Completed |
NCT01821742 -
Echocardiography in Kids Intensive Care Decision Support
|
||
Completed |
NCT04802668 -
Factors Influencing of Pulse Pressure Variation (PPV)
|
||
Not yet recruiting |
NCT06254456 -
Fluid Responsiveness in Prone Patients
|
N/A | |
Completed |
NCT02789124 -
Diagnostic Value of Passive Leg Raise Induced Changes in Carotid Artery Flow Time to Predict Fluid Responsiveness in Critically Ill Patients
|
N/A | |
Completed |
NCT02040948 -
Accuracy of Pulse Pressure Variation and of Pleth Variability Index to Predict the Response to a Fluid Challenge
|
N/A | |
Withdrawn |
NCT01898975 -
A Gray Zone Approach to Stroke Volume Variation Derived From NICOM
|
N/A |