Fluid Responsiveness Clinical Trial
Official title:
Combination of Static Echocardiographic Indices for Prediction of Fluid Responsiveness During Cardiac Surgery
In the perioperative or critical care of hemodynamically unstable patients, appropriate fluid resuscitation guided by reliable preload indices is of pivotal importance as only half of them are fluid responsive, and that empiric fluid administration actually leads to dismal prognosis. In the continuum of being non-invasive, combinations of tissue Doppler-derived parameters of early (e') and late (a') diastolic, and peak systolic velocity (s') of the mitral annulus provide information regarding the systolic dysfunction and preload (e'/s'), and LV stiffness (e'/a'). Although the left ventricular end-diastolic area (LVEDA) alone is not a valid predictor of fluid responsiveness, combining LVEDA with these indices would provide comprehensive information regarding the LV dimension, preload, and compliance as well as systolic function. Also, it seems logical to assume that patients with low LVEDA and high e' velocity indicating preserved early diastolic relaxation or low e (early mitral inflow velocity) /e' ratio indicating normal LV filling pressure would more likely be fluid responsive. Yet, these assumptions have not been tested before. Moreover, these values can be reliably obtained regardless of the heart rhythm, except for a', and do not completely rely on heart-lung interaction as opposed to the dynamic indices. Thus, the aim of this prospective trial is to investigate the role of LVEDA combined with e, e', a' or s' as a preload index in predicting fluid responsiveness in patients scheduled for off-pump coronary bypass surgery, in closed-chest conditions.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT01941472 -
Transcutaneous pO2, Transcutaneous pCO2 and Central Venous pO2 Variations to Predict Fluid Responsiveness
|
N/A | |
Terminated |
NCT03208023 -
RESIPI for Reducing Perioperative Major Adverse Cardiac Events
|
N/A | |
Completed |
NCT03713008 -
Assessment Of Carotid Flow During General Anesthesia
|
N/A | |
Completed |
NCT02277353 -
Evaluation of SVV From NICOM as a Predictor of Fluid Responsiveness in Prone Position During Spine Surgery
|
N/A | |
Not yet recruiting |
NCT04092036 -
Optic Nerve Sheath Diameter in Prediction of Fluid Responsiveness
|
||
Completed |
NCT04060069 -
Pneumoperitoneum and Trendelenburg Position on Fluid Responsiveness
|
||
Recruiting |
NCT05153837 -
Effect of Oral Water in Healthy Volunteers on Cardiac Output, Regional Flow and Microcirculation in Healthy Volunteers
|
N/A | |
Not yet recruiting |
NCT06143111 -
A Comparison of Thoracic Electrical Bioimpedance and FloTrac/Vigileo
|
N/A | |
Not yet recruiting |
NCT05601622 -
RPVI for Fluid Responsiveness in Children
|
N/A | |
Completed |
NCT04889807 -
Study of End Tidal Carbon Dioxide (EtCO2) Variation After an End- Expiratory Occlusion Test as a Predictive Criteria of Fluid Responsiveness in Mechanically Ventilated Patients
|
||
Recruiting |
NCT04186416 -
Effectiveness of the Pressure Recording Analytical Method in Predicting Fluid Responsiveness in Pediatric Critical Care Patients
|
||
Completed |
NCT01996956 -
Prediction of Fluid Responsiveness by NICOM (Non-invasive Cardiac Output Monitoring) in Children With Congenital Heart Disease After Cardiac Surgery
|
N/A | |
Enrolling by invitation |
NCT04388995 -
SVV and PPV Predict Fluid Responsiveness in Mechanically Ventilated Elderly Patients Under General Anesthesia
|
N/A | |
Not yet recruiting |
NCT04574011 -
Fluid Responsiveness in Spontaneously Ventilating Patient
|
N/A | |
Completed |
NCT01821742 -
Echocardiography in Kids Intensive Care Decision Support
|
||
Completed |
NCT04802668 -
Factors Influencing of Pulse Pressure Variation (PPV)
|
||
Not yet recruiting |
NCT06254456 -
Fluid Responsiveness in Prone Patients
|
N/A | |
Completed |
NCT02789124 -
Diagnostic Value of Passive Leg Raise Induced Changes in Carotid Artery Flow Time to Predict Fluid Responsiveness in Critically Ill Patients
|
N/A | |
Withdrawn |
NCT01898975 -
A Gray Zone Approach to Stroke Volume Variation Derived From NICOM
|
N/A | |
Completed |
NCT02040948 -
Accuracy of Pulse Pressure Variation and of Pleth Variability Index to Predict the Response to a Fluid Challenge
|
N/A |