Clinical Trials Logo

Clinical Trial Summary

Essential tremor is an incurable, degenerative brain disorder that results in increasingly debilitating tremor, and afflicts an estimated 7 million people in the US. In one study, 25% of essential tremor patients were forced to change jobs or take early retirement because of tremor. Essential tremor is directly linked to progressive functional impairment, social embarrassment, and even depression. The tremor associated with essential tremor is typically slow, involves the hands (and sometimes the head and voice), worsens with intentional movements, and is insidiously progressive over many years. Deep brain stimulation has emerged as a highly effective treatment for intractable, debilitating essential tremor. However, since the intention tremor of essential tremor is typically intermittent, and commonly absent at rest, the currently available continuous deep brain stimulation may be delivering unnecessary current to the brain that increases undesirable side effects such as slurred speech and walking difficulty, and hastens the depletion of device batteries, necessitating more frequent surgical procedures to replace spent pulse generators. The overall objective of this early feasibility study is to provide preliminary data on the safety and efficacy of "closed-loop" deep brain stimulation for intention tremor using novel deep brain stimulation devices capable of continuously sensing brain activity and delivering therapeutic stimulation only when necessary to suppress tremor.


Clinical Trial Description

The purpose of this study is to investigate brain signals related to intention tremor in essential tremor in order to deliver deep brain stimulation only when the patient is showing symptoms. By delivering stimulation only when needed, the investigators hypothesize that the treatment will be more effective, will cause fewer adverse side effects and will increase battery time of the device (reducing the number of battery replacement surgeries). Participation in this study will require extensive pre-surgical screening to determine eligibility for deep brain stimulation surgery, a deep brain stimulation surgical procedure, and regular follow-ups. Subjects will be seen monthly post surgery for 6 months. After 6 months, data will be assessed and closed-loop deep brain stimulation may be offered as a stimulation setting. If so, the stimulator settings will be changed from chronic to responsive. If not, the subject will continue to receive chronic deep brain stimulation stimulation. Subsequent visits will be scheduled every 6 months until a total of 24 months of study participation (also at month 9). At the end of the initial 24-month study period, subjects will have the choice of 1) continuing active stimulation at the current setting, 2) continuing stimulation but searching for a new setting, 3) discontinuing stimulation (turning the device off), 4) having the device removed. If the subject continues to receive active stimulation, they will be followed by the investigators and seen at yearly intervals. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02649166
Study type Interventional
Source University of Florida
Contact
Status Active, not recruiting
Phase N/A
Start date February 1, 2017
Completion date June 30, 2024

See also
  Status Clinical Trial Phase
Withdrawn NCT05381688 - VIM DBS Respiratory Modulation: N-of-1 Trial
Recruiting NCT05101161 - Neurofeedback Using Implanted Deep Brain Stimulation Electrodes N/A
Completed NCT02277106 - Evaluate SAGE-547 in Participants With Essential Tremor Phase 2
Recruiting NCT05769933 - Bridging Gaps in the Neuroimaging Puzzle: New Ways to Image Brain Anatomy and Function in Health and Disease Using Electroencephalography and 7 Tesla Magnetic Resonance Imaging
Terminated NCT02894567 - Evaluation of Directional Recording and Stimulation Using spiderSTN N/A
Terminated NCT02678429 - Atlas Predicted DBS Settings in Essential Tremor N/A
Completed NCT02523807 - Tremor Monitoring Device N/A
Active, not recruiting NCT02255929 - Gamma Knife Radiosurgery for Treatment of Essential Tremor N/A
Completed NCT01223144 - Decision-making and Emotion Recognition in Essential Tremor N/A
Completed NCT00906412 - Ventrointermediate Nucleus (VIM DBS) and Working Memory N/A
Recruiting NCT05214222 - Penpulimab Plus Chemotherapy With/Without Anlotinib for Patients With Advanced Esophageal Squamous Cell Carcinoma Phase 2
Completed NCT03051178 - Wearable Sensor for Responsive DBS for ET N/A
Recruiting NCT03795935 - Relief From Side Effects: Clinical Use of Electrodes With Direction N/A
Not yet recruiting NCT06036368 - Study to Evaluate Safety and Efficacy of Peroneal Transcutaneous NeuroModulation in Subjects With Parkinson's Disease and Essential Tremor N/A
Recruiting NCT05897775 - Coordinated Reset Deep Brain Stimulation for Essential Tremor Phase 1
Recruiting NCT05968976 - Multicentre RCT of Awake Versus Asleep Tractography Based DBS for ET N/A
Completed NCT06314139 - Tolerability and Efficacy of Continuous Theta-burst Stimulation for Essential Tremor: A Randomized Study. N/A
Recruiting NCT04501133 - Sensory-specific Peripheral Stimulation for Tremor Management N/A
Active, not recruiting NCT03560622 - Functional Neuroimaging Feedback for Focused Ultrasound Thalamotomy N/A
Completed NCT00368199 - Transcranial Duplex Scanning and Single Photon Emission Computer Tomography (SPECT) in Parkinsonian Syndromes N/A