Esophageal Cancer Clinical Trial
Official title:
Utility and Usability of ActivSight™ Laser Speckle Imaging in Visualization of Tissue Perfusion and Blood Flow During Esophageal Surgery in Humans
NCT number | NCT05591053 |
Other study ID # | ACF0052020 |
Secondary ID | |
Status | Recruiting |
Phase | N/A |
First received | |
Last updated | |
Start date | April 1, 2023 |
Est. completion date | January 2025 |
ActivSight™ combines an innovative form factor and proprietary software to deliver precise, objective, real-time visualization of blood flow and tissue perfusion intraoperatively for laparoscope-based surgery. A small adaptor that fits between any existing laparoscope and camera systems and a separate light source placed along any current commercial system will deliver objective real-time tissue perfusion and blood flow information intraoperatively. Primary Objective: To determine the feasibility of ActivSight™ in detecting and displaying tissue perfusion and blood flow in the conduit and foregut anastomoses in esophageal resection/reconstructive surgery. The investigators will compare the precision and accuracy among the naked eye inspection, ICG and LSCI in assessing the vascularity of the conduit.
Status | Recruiting |
Enrollment | 70 |
Est. completion date | January 2025 |
Est. primary completion date | January 2025 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 18 Years and older |
Eligibility | INCLUSION CRITERIA All patients age > 18 years old undergoing laparoscopic esophageal resection and reconstruction surgery; spoken command and literacy in the native language spoken at each participating center; ability to understand and follow study procedures; and having provided signed consent. Diagnosis: - All patients with a clinical suspicion and diagnosis of benign or malignant, small or large bowel lesions requiring surgical resection. - Typical imaging as per standard workup findings including US, CT and/or MRI. Plain radiographs and contrast imaging may be obtained by referring physicians and are helpful for confirming the clinical diagnosis. Location of pathology or resected segment: * Target lesions can be located in any fore-, mid- or hindgut segments requiring reconstruction and anastomoses. Prior therapy: * Patients with prior surgery are eligible for enrollment. Laboratory: - Hemoglobin > 9 g/dL - Platelet count =75,000/µL (may receive transfusions) - Normal PT, PTT and INR < 1.5 x ULN (including patients on prophylactic anticoagulation) - Renal function: Age-adjusted normal serum creatinine derived from Schwartz formula for estimating GFR by the CDC OR a creatinine clearance =60 mL/min/1.73 m2 for safe - Adequate pulmonary function: Defined as no dyspnea at rest, and a pulse oximetry >94% on room air if there is clinical indication for determination. EXCLUSION CRITERIA - There is no exclusion criteria for ActivSightTM for esophageal surgery. - Patients assigned to FDA cleared ICG-based visualization are contraindicated for any chronic renal dysfunction, potential drug interaction, history of allergy to ICG or anaphylaxis, known allergy to iodides, breast-feeding or being of reproductive age with pregnancy possible and not ruled out, and pregnancy. - Patients currently in any investigational agents. |
Country | Name | City | State |
---|---|---|---|
United States | University of Pittsburgh Medical Center - Dept of Cardiothoracic Surgery | Pittsburgh | Pennsylvania |
United States | West Penn Hospital / Allegheny Health Network | Pittsburgh | Pennsylvania |
Lead Sponsor | Collaborator |
---|---|
Activ Surgical | University of Pittsburgh Medical Center, West Penn Allegheny Health System |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Incidence of Adverse Events in 28 days following use of ActivSight™ | To determine safety of ActivSight™ in patients undergoing esophageal surgery, as defined through clinical assessments and evaluation of use related adverse events intraoperatively and a routine follow up at 28 days following surgery. ActivSight™ will be deemed safe if no hardware (adaptor or light source)-related major (serious) adverse event is encountered in the treated patients and if less than 2 hardware-related minor adverse events are encountered.
Adverse events will be summarized descriptively and tabulations on the type, severity, and relationship to application will be performed and any changes of outcomes from baseline on follow up will be examined using the nonparametric Wilcoxon rank test. |
28 days | |
Primary | Preparation time of ActivSight™. | Rate on a scale of 1-5 (1 = Difficult to use or Unsatisfied - 5 = no training required or very satisfied): How easy was ActivSight to set up? | 1 day | |
Primary | Latency of display of ActivSight™. | Rate on a scale of 1-5 (1 = Difficult to use or Unsatisfied - 5 = no training required or very satisfied): How specifically did ActivSight display the intended field and the target tissue of interest? | 1 day | |
Primary | Resolution and objectivity of display of ActivSight™. | Rate on a scale of 1-5 (1 = Difficult to use or Unsatisfied - 5 = no training required or very satisfied): How was the display quality of ActivSight on the intended field and target tissue of interest? | 1 day | |
Primary | Specificity of display of ActivSight™. | Specificity of display will serve as an outcome for feasibility. Yes/No question for surgeon: "Does the perfusion information displayed by ActivSightTM reflect the expected pattern of blood flow interruption?" | 1 day | |
Primary | Usability of ActivSightTM by surgeon, as quantified by Likert scale. | Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree): "ActivSightTM was easy to use while operating." | 1 day | |
Primary | Support personnel satisfaction with ActivSightTM, as quantified by Likert scale. | Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree): "ActivSightTM was easy to set up for the procedure." | 1 day | |
Primary | User feedback on utility of relative perfusion unit display versus color heatmap | Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree): | 1 day | |
Primary | Episodes of intraoperative decision change based on display | Yes/No if surgeons changed intraoperative planning/decisions based on ActivSight™, with additional details (what did they change and why) requested if yes. | 1 day | |
Primary | Usability of the device by surgeon and support personnel satisfaction; | Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree): | 1 day | |
Secondary | Ability of ActivSightTM to display perfusion. | ActivSightTM ability to display perfusion at a tissue level during gastrointestinal anastomoses is measured by the following Yes/No question for the surgeon: "Does ActivSightTM display tissue perfusion of the anatomy during anastomoses in comparison to ICG?" | 1 day | |
Secondary | Ability of ActivSightTM to display blood vessels. | ActivSightTM ability to display blood vessels during gastrointestinal anastomoses is measured by the following Yes/No question for the surgeon: "Does ActivSightTM display vascularity of the anatomy during anastomoses in comparison to ICG?" | 1 day |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06006390 -
CEA Targeting Chimeric Antigen Receptor T Lymphocytes (CAR-T) in the Treatment of CEA Positive Advanced Solid Tumors
|
Phase 1/Phase 2 | |
Terminated |
NCT01624090 -
Mithramycin for Lung, Esophagus, and Other Chest Cancers
|
Phase 2 | |
Recruiting |
NCT05787522 -
Efficacy and Safety of AI-assisted Radiotherapy Contouring Software for Thoracic Organs at Risk
|
||
Not yet recruiting |
NCT05542680 -
Study on the Design and Application of Special Semi Recumbent Cushion for Postoperative Patients With Esophageal Cancer
|
N/A | |
Completed |
NCT03384511 -
The Use of 18F-ALF-NOTA-PRGD2 PET/CT Scan to Predict the Efficacy and Adverse Events of Apatinib in Malignancies.
|
Phase 4 | |
Completed |
NCT00003864 -
Docetaxel Plus Carboplatin in Treating Patients With Advanced Cancer of the Esophagus
|
Phase 2 | |
Recruiting |
NCT05491616 -
Nivolumab During Active Surveillance After Neoadjuvant Chemoradiation for Esophageal Cancer: SANO-3 Study
|
Phase 2 | |
Active, not recruiting |
NCT04383210 -
Study of Seribantumab in Adult Patients With NRG1 Gene Fusion Positive Advanced Solid Tumors
|
Phase 2 | |
Completed |
NCT00199849 -
NY-ESO-1 Plasmid DNA (pPJV7611) Cancer Vaccine
|
Phase 1 | |
Completed |
NCT03756597 -
PAN-study: Pan-Cancer Early Detection Study (PAN)
|
||
Completed |
NCT00400114 -
Sutent Following Chemotherapy, Radiation and Surgery For Resectable Esophageal Cancer
|
Phase 2 | |
Completed |
NCT03652077 -
A Safety and Tolerability Study of INCAGN02390 in Select Advanced Malignancies
|
Phase 1 | |
Recruiting |
NCT04615806 -
The Value of Lymph Node Dissection of Indocyanine Green-guided Near-infrared Fluorescent Imaging in Esophagectomy
|
N/A | |
Active, not recruiting |
NCT04566367 -
Blue Laser Imaging (BLI) for Detection of Secondary Head and Neck Cancer
|
N/A | |
Active, not recruiting |
NCT03962179 -
Feasibility and Efficacy of a Combination of a SEMS and Vacuum Wound Treatment (VACStent)
|
N/A | |
Terminated |
NCT01446874 -
Prevention of Post-operative Pneumonia (POPP)
|
Phase 2/Phase 3 | |
Completed |
NCT03468634 -
Raman Probe for In-vivo Diagnostics (During Oesophageal) Endoscopy
|
N/A | |
Active, not recruiting |
NCT02869217 -
Study of TBI-1301 (NY-ESO-1 Specific TCR Gene Transduced Autologous T Lymphocytes) in Patients With Solid Tumors
|
Phase 1 | |
Completed |
NCT02810652 -
Perioperative Geriatrics Intervention for Older Cancer Patients Undergoing Surgical Resection
|
N/A | |
Recruiting |
NCT02544737 -
Apatinib for Metastatic Esophageal Cancer.
|
Phase 2 |