Edentulous Jaw Clinical Trial
Official title:
Accuracy of Impression Techniques and Their Effect on the Passive Fit of Screw- Retained Bar Splinting Two Interforaminal Implants
Verified date | February 2024 |
Source | Ain Shams University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Objectives: Passive fit of screw retained frameworks is essential to avoid biological and mechanical failures in addition to transmission of unfavourable stresses to the bone-implant interface. However, Several factors contribute to the passive fit of screw retained prosthesis such as relative parallelism between the implants, implant number, impression material, impression technique and method of prothesis fabrication. The current study aims to evaluate the accuracy of three different impression techniques on the fit of screw retained bar splinting two inter-foraminal implants. Methods: The study presents evaluation of the passive fit of screw retained bar fabricated with three different impression techniques.
Status | Active, not recruiting |
Enrollment | 54 |
Est. completion date | May 1, 2024 |
Est. primary completion date | May 1, 2024 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 50 Years to 65 Years |
Eligibility | Inclusion Criteria: - - Patients' age range from 50 to 65 years old. - Good oral hygiene is mandatory. - Sufficient restorative space (15mm) to accept implant supported over denture diagnosed by mounting the diagnostic casts. - Firm and healthy mucosa covering the alveolar ridge. - Minimum bone width 5.5 mm buccolingually and of 12 mm bone height as diagnosed from the pre-operative cone beam computed tomography scan. Exclusion Criteria: - Heavy smokers. - Patients with para functional habits. - Tempromandibular Joint Disorders. (TMJ disorders) - Patients with systemic disorders that may affect the results of this study. - V-shaped dental arch. |
Country | Name | City | State |
---|---|---|---|
Egypt | Faculty of Dentistry Ain Shams University | Cairo |
Lead Sponsor | Collaborator |
---|---|
Ain Shams University |
Egypt,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | linear accuracy of impressions by superimposition | accurate details recorded by superimposition of the impressions using geomagic software program by measuring linear deviation in millimeters | 1 year | |
Primary | Angular accuracy of impressions by superimposition | accurate details recorded by superimposition of the impressions using geomagic software program by measuring angular displacements in degrees | 1 year | |
Primary | passive fit of screw retained bars | frame work fitting passively using screw resistance test using screw resistance parameter calculated by subtraction of passive and non passive situations angles of rotation in degrees | one year |
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT05082038 -
Mandibular Full-arch Rehabilitation With Internal Hexagonal and Conical Connection Implants
|
N/A | |
Completed |
NCT01411683 -
Mandibular Overdentures Retained by Conventional or Mini Implants
|
N/A | |
Completed |
NCT05924451 -
Study of Hard and Soft Tissue Behavior Around Abutments on Implants.
|
N/A | |
Completed |
NCT04851002 -
Effects of Different Centrifuged Platelet Concentrates on Bone Remodelling Around Dental Implants
|
N/A | |
Completed |
NCT01230320 -
Simplified vs. Conventional Methods for Complete Denture Fabrication
|
N/A | |
Active, not recruiting |
NCT05062863 -
An Observational Clinical Study of the T3 Dental Implant System
|
||
Active, not recruiting |
NCT04354688 -
T3 Certain Tapered With DCD vs T3 Certain Tapered Non-DCD
|
N/A | |
Not yet recruiting |
NCT06152432 -
Maxillary Implant Overdentures Retained by Bars or Locator
|
N/A | |
Completed |
NCT06209814 -
Evaluation of Open-face Maxillary Complete Denture for Patients With Prominent Premaxilla
|
N/A | |
Recruiting |
NCT04662333 -
Adjunctive Benefit of Xenograft Plus a Membrane During Sinus Crestal Approach
|
N/A | |
Active, not recruiting |
NCT04236336 -
A Clinical Study of the TSV Dental Implant System
|
||
Active, not recruiting |
NCT04237545 -
A Clinical Study of the T3 Short Dental Implant System
|
N/A | |
Not yet recruiting |
NCT03674554 -
Prosthetic Complications of Screw Retained Restoration
|
N/A | |
Not yet recruiting |
NCT06155630 -
3D Printing for the Fabrication of Mandibular Implant Overdentures
|
N/A | |
Recruiting |
NCT04429373 -
Effect of Platelet-rich Plasm (PRF) on Two-implant Mandibular Overdenture: a Split Mouth
|
N/A | |
Completed |
NCT06146153 -
Intra Oral Scanning of Edentulous Arches
|
||
Completed |
NCT05777980 -
Effect of Prosthetic Rehabilitation on Nutritional Status of Geriatric Patients
|
||
Completed |
NCT03992300 -
Comparison of Full-arch Implant-supported Frameworks From an Intraoral Scanning or From a Conventional Impression
|
N/A | |
Completed |
NCT03538184 -
Molecular Content of Peri-implant Sulcus During Wound Healing and Osseointegration Following Drilling and Piezosurgery
|
N/A | |
Not yet recruiting |
NCT06393582 -
Accuracy Evaluation of Implant Impressions: A Prospective Study
|
N/A |