Edentulous Jaw Clinical Trial
Official title:
Attachment-retained Unilateral Partial Denture Versus Tooth Implant Supported Prosthesis in Mandibular Distal Extension Cases
Purpose: Evaluation of patients' satisfaction, biting force measurement and radiographic
evaluation of abutment teeth of tooth implant supported bridge, unilateral attachment and
conventional partial denture in mandibular distal extension cases.
Materials and methods: Twenty four patients were selected and divided into three equal
groups, each of eight patients: patients of group I Patients received a fixed tooth implant
supported bridge, patients of group II Patients received a removable unilateral attachment
partial denture and group III Patients received a conventional removable partial
denture.Evaluation included patient satisfaction and biting force measurement radiographic
evaluation of terminal abutments.
Purpose: Evaluation of patients' satisfaction, biting force measurement and radiographic
evaluation of abutment teeth of tooth implant supported bridge, unilateral attachment and
conventional partial denture in mandibular distal extension cases.
Materials and methods: Twenty four patients were selected according to the following
criteria: Patients with unilateral mandibular distal extension with last standing second
premolar abutment, abutments showed sufficient occluso-gingival height and good periodontal
condition. Patients were divided into three equal groups, each of eight patients: patients of
group I Patients received a fixed tooth implant supported bridge, patients of group II
Patients received a removable unilateral attachment partial denture and group III Patients
received a conventional removable partial denture.Evaluation included patient satisfaction
using "OHIP14" questionnaires and biting force measurement radiographic evaluation of
terminal abutments.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT05082038 -
Mandibular Full-arch Rehabilitation With Internal Hexagonal and Conical Connection Implants
|
N/A | |
Completed |
NCT01411683 -
Mandibular Overdentures Retained by Conventional or Mini Implants
|
N/A | |
Completed |
NCT05924451 -
Study of Hard and Soft Tissue Behavior Around Abutments on Implants.
|
N/A | |
Completed |
NCT04851002 -
Effects of Different Centrifuged Platelet Concentrates on Bone Remodelling Around Dental Implants
|
N/A | |
Completed |
NCT01230320 -
Simplified vs. Conventional Methods for Complete Denture Fabrication
|
N/A | |
Active, not recruiting |
NCT05062863 -
An Observational Clinical Study of the T3 Dental Implant System
|
||
Active, not recruiting |
NCT04354688 -
T3 Certain Tapered With DCD vs T3 Certain Tapered Non-DCD
|
N/A | |
Not yet recruiting |
NCT06152432 -
Maxillary Implant Overdentures Retained by Bars or Locator
|
N/A | |
Completed |
NCT06209814 -
Evaluation of Open-face Maxillary Complete Denture for Patients With Prominent Premaxilla
|
N/A | |
Recruiting |
NCT04662333 -
Adjunctive Benefit of Xenograft Plus a Membrane During Sinus Crestal Approach
|
N/A | |
Active, not recruiting |
NCT04236336 -
A Clinical Study of the TSV Dental Implant System
|
||
Active, not recruiting |
NCT04237545 -
A Clinical Study of the T3 Short Dental Implant System
|
N/A | |
Not yet recruiting |
NCT03674554 -
Prosthetic Complications of Screw Retained Restoration
|
N/A | |
Not yet recruiting |
NCT06155630 -
3D Printing for the Fabrication of Mandibular Implant Overdentures
|
N/A | |
Recruiting |
NCT04429373 -
Effect of Platelet-rich Plasm (PRF) on Two-implant Mandibular Overdenture: a Split Mouth
|
N/A | |
Completed |
NCT06146153 -
Intra Oral Scanning of Edentulous Arches
|
||
Completed |
NCT05777980 -
Effect of Prosthetic Rehabilitation on Nutritional Status of Geriatric Patients
|
||
Completed |
NCT03992300 -
Comparison of Full-arch Implant-supported Frameworks From an Intraoral Scanning or From a Conventional Impression
|
N/A | |
Completed |
NCT03538184 -
Molecular Content of Peri-implant Sulcus During Wound Healing and Osseointegration Following Drilling and Piezosurgery
|
N/A | |
Not yet recruiting |
NCT06393582 -
Accuracy Evaluation of Implant Impressions: A Prospective Study
|
N/A |