Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01874275
Other study ID # VECTTOR DMD2012
Secondary ID
Status Completed
Phase N/A
First received June 7, 2013
Last updated April 14, 2015
Start date June 2013
Est. completion date September 2014

Study information

Verified date April 2015
Source Alan Neuromedical Technologies, LLC
Contact n/a
Is FDA regulated No
Health authority United States: Institutional Review Board
Study type Interventional

Clinical Trial Summary

The primary objective of this investigation is to assess the effectiveness of transcutaneous electrical nerve stimulation applied using VECTTOR to reduce the symptoms of Duchenne Muscular Dystrophy and reduce the impact of DMD upon the participants' quality of life.

The primary outcome measures will include:

1. increased muscle strength,

2. increased range of joint motions and

3. improved sleep parameters of ASI, N3 and REM.


Description:

Muscle Strength and Joint Range of Motion Testing - All muscle and joint testing was performed at the MedCenter Therapy clinic in Houston, Texas. JTech computerized testing system was utilized including Goniometry, Grip testing, Inclinometry, Muscle Testing and Joint Range of Motion testing occurred on Day 0, 30, 60, 90, 180, and repeated at 12 months to determine muscular strength and joint Range of Motion. JTech computerized testing system was chosen on the basis of reliability and accuracy. At each of the testing intervals, the testing was administered by the same technician with the same equipment to all of the participants. Inter-and intra-tester reliability of the JTech computerized testing system has been the subject of multiple studies. Each of which found high ICCs (>0.93) for both inter- and intra-tester reliability.

All sleep studies were performed at Sleep Diagnostics of Texas in The Woodlands, Texas. Prior to the clinical trial, all of the participants spent two nights in the sleep unit and their sleep study examinations were performed. The second night was used as the Day 0 data. Sleep, breathing, arousals and limb movements were scored manually according to guidelines set forth by the American Academy of Sleep Medicine. The sleep studies were repeated at 6 months and 1 year.


Recruitment information / eligibility

Status Completed
Enrollment 6
Est. completion date September 2014
Est. primary completion date September 2014
Accepts healthy volunteers No
Gender Both
Age group 8 Years to 20 Years
Eligibility Inclusion Criteria:

- Participants must have Duchenne Muscular Dystrophy diagnosis as confirmed by licensed physician, wheelchair bound, & age 8 - 20 years old.

Exclusion Criteria:

- Active cancer in the area of application of the treatment, infection, skin infection, pregnancy, thrombophlebitis, pacemaker, amputation of any part of feet or hands, taking steroids. In addition, the participant may not be in any other clinical trial during the time they are in this study.

Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Crossover Assignment, Masking: Double Blind (Subject, Caregiver, Investigator, Outcomes Assessor), Primary Purpose: Treatment


Intervention

Device:
VECTTOR
The VT-200, or VECTTOR system, delivers electrical stimulation via electrodes on the acupuncture points of a patient's feet/legs and hands/arms to provide symptomatic relief of chronic intractable pain and/or management of post-surgical pain. Once these electrodes are placed, the machine determines the appropriate choice of stimulation by automatically measuring body temperatures through the use of thermistors placed on the fingers during a testing sequence.

Locations

Country Name City State
United States Alan Neuromedical Houston Texas

Sponsors (1)

Lead Sponsor Collaborator
Alan Neuromedical Technologies, LLC

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Other Percent Change in Sleep Quality Arousal Statistics Index (ASI) From Baseline to 180 Days Sleep / Arousal Statistics Index (ASI) description: Sleep Studies were obtained twice before beginning the study. The second sleep study data was used as baseline. A follow up sleep study was obtained after 6 months (180 days) of Active or Placebo VECTTOR treatment. Sleep, breathing, arousal(s), and limb movements were scored manually according to guidelines of the American Academy of Sleep Medicine. The efficacy of the outcome measure of ASI is demonstrated by a percent improvement between Baseline and 180 days. The ASI is measured by the number of times sleep is interrupted per hour. Baseline to 180 days No
Other Sleep Arousal Statistics Index at 365 Days Sleep / Arousal Statistics Index (ASI) description: Sleep Studies were obtained twice before beginning the study. The second sleep study data was used as baseline. A follow up sleep study was obtained after 6 months (180 days) of Active or Placebo VECTTOR treatment. Sleep, breathing, arousal(s), and limb movements were scored manually according to guidelines of the American Academy of Sleep Medicine. The efficacy of the outcome measure of ASI is demonstrated by a decrease in the value between Baseline and 180 days. The ASI is measured by the number of times sleep is interrupted per hour. Lower ASI values/numbers indicate improved sleep quality. Baseline to 365 days No
Primary Percent Change in Range of Motion From Baseline to 180 Days Range of Motion (ROM) testing (Wireless Tracker System) - All muscle and joint testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion. Testing occurred at Baseline (Day 0), 30, 60, 90 and 180 days to determine changes in joint Range of Motion. JTech computerized testing system determined the joint range of motion by radio signals from a goniometer measuring movement of the participants' joints. 44 separate tests were performed for Range of Motion for each participant at each time interval. The results from the range of motion tests were averaged the percent change from baseline to 180 days. Efficacy is defined as an increase in range of motion. Baseline to 180 days No
Secondary Percent Change in Muscle Strength Muscle strength testing (Wireless Tracker system) - All muscle strength testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion. Testing occurred at Baseline (Day 0), 30, 60, 90, and 180 days to determine changes in muscle strength. JTech computerized testing system determined the muscle strength by radio signals from a strain gauge measuring strength of the participant's muscles. 44 separate tests were performed for muscle strength for each participant at each time interval. Efficacy is defined as an increase in the strength measurement (pounds) from Baseline to 180 days. Baseline to 180 days No
Secondary Percent Change in Percent Range of Motion From Baseline to 365 Days Range of Motion (ROM) testing (Wireless Tracker System) - All muscle and joint testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion. Testing occurred at Baseline (Day 0), 30, 60, 90, 180 and 365 days to determine changes in joint Range of Motion. JTech computerized testing system determined the joint range of motion by radio signals from a goniometer measuring movement of the participants' joints. 44 separate tests were performed for Range of Motion for each participant at each time interval. The results from the range of motion tests were averaged the percent change from baseline to 365 days. Efficacy is defined as an increase in range of motion. Baseline to 365 days No
Secondary Percent Change in Muscle Strength Muscle strength testing (Wireless Tracker system) - All muscle strength testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion. Testing occurred at Baseline (Day 0), 30, 60, 90, 180 and 365 days to determine changes in muscle strength. JTech computerized testing system determined the muscle strength by radio signals from a strain gauge measuring strength of the participant's muscles. 44 separate tests were performed for muscle strength for each participant at each time interval. Efficacy is defined as an increase in the strength measurement (pounds) from Baseline to 365 days. Baseline to 365 days No
See also
  Status Clinical Trial Phase
Completed NCT05575648 - Dual Task in Duchenne Muscular Dystrophy N/A
Terminated NCT03907072 - Efficacy and Safety Study of WVE-210201 (Suvodirsen) With Open-label Extension in Ambulatory Patients With Duchenne Muscular Dystrophy Phase 2/Phase 3
Not yet recruiting NCT06450639 - An Open-label Study to Assess the Efficacy and Safety of Satralizumab in Duchenne Muscular Dystrophy Phase 2
Completed NCT04335942 - Characterization of the Postural Habits of Wheelchair Users Analysis of the Acceptability of International Recommendations in the Prevention of Pressure Sores Risk by Using a Connected Textile Sensor N/A
Active, not recruiting NCT04906460 - Open-label Study of WVE-N531 in Patients With Duchenne Muscular Dystrophy (FORWARD-53) Phase 1/Phase 2
Active, not recruiting NCT02500381 - Study of SRP-4045 (Casimersen) and SRP-4053 (Golodirsen) in Participants With Duchenne Muscular Dystrophy (DMD) Phase 3
Enrolling by invitation NCT05967351 - A Long-term Follow-up Study of Participants Who Received Delandistrogene Moxeparvovec (SRP-9001) in a Previous Clinical Study Phase 3
Recruiting NCT03067831 - Bone Marrow-Derived Autologous Stem Cells for the Treatment of Duchenne Muscular Dystrophy Phase 1/Phase 2
Recruiting NCT01834040 - Study Safety and Efficacy of BMMNC for the Patient With Duchenne Muscular Dystrophy Phase 1/Phase 2
Completed NCT02246478 - A Study of TAS-205 for Duchenne Muscular Dystrophy Phase 1
Active, not recruiting NCT01772043 - Duchenne Muscular Dystrophy Tissue Bank for Exon Skipping N/A
Terminated NCT01168908 - Revatio for Heart Disease in Duchenne Muscular Dystrophy and Becker Muscular Dystrophy Phase 2
Completed NCT00758225 - Long-term Safety, Tolerability and Efficacy of Idebenone in Duchenne Muscular Dystrophy (DELPHI Extension) Phase 2
Completed NCT03680365 - Your Voice; Impact of Duchenne Muscular Dystrophy (DMD) on the Lives of Families
Recruiting NCT03513367 - The Validation Process for Confirmation of the French Version of the Pediatric Quality of Life Inventory :PedsQLTM.
Recruiting NCT05712447 - Duchenne Muscular Dystrophy Video Assessment Registry
Recruiting NCT01484678 - Magnetic Resonance Imaging and Biomarkers for Muscular Dystrophy
Completed NCT03319030 - Aerobic Exercise in Boys With Duchenne Muscular Dystrophy (DMD)
Terminated NCT01753804 - A Prospective Natural History Study of Progression of Subjects With Duchenne Muscular Dystrophy. N/A
Completed NCT02530905 - Dose-Titration and Open-label Extension Study of SRP-4045 in Advanced Stage Duchenne Muscular Dystrophy (DMD) Patients Phase 1